RRIA-01

Resolver Interface Module
In Stock
Ships by Tuesday, September 22
Fast Shipping Available

Product Describe:

ABB RRIA-01 is a resolver interface module. It provides accurate motor-shaft speed and angular-position feedback within the installed ABB ACS800 drive.

Ask our team:

Get a quick price for: RRIA-01
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for RRIA-01

Technical specifications for RRIA-01

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    3ABD68486408
  • Estimated shipping dimensions:
    11.5×2.0×9.5cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Resolver connection:
    Analog resolver
  • Drive option slots:
    SLOT 1 or SLOT 2
  • External adapter:
    AIMA-01
  • Parallel-bus connector:
    38-pin
  • Resolver terminal block:
    8-pole screw type
  • Terminal wire size, max.:
    2.5 mm2
  • Resolver cable construction:
    4 x (2+1) twisted pairs; individual and overall shields
  • Resolver conductor area:
    0.5 to 1.0 mm2
  • Resolver cable length, max.:
    100 m
  • Excitation frequency:
    10 kHz or 20 kHz
  • Excitation output, max.:
    12 Vpp
  • Resolver input level:
    8 Vpp
  • Position feedback resolution:
    12 bits (0.024%)
  • Node ID range:
    16 to 31
  • Default node ID:
    16
  • Pole-pair setting:
    1, 2, 3 or 4
  • Degree of protection:
    IP20
  • Power consumption:
    180 mA at 5 V + 80 mA at 24 V
  • Isolation test voltage:
    1.5 kV AC for 1 min
  • Estimated minimum lifetime:
    100000 h
  • Diagnostic LEDs:
    CHA/CHB green; WD/INIT yellow; ERR red

Information

Information

Overview Manuals Common Applications Product Precautions
Resolver Interface Module provides the documented interface for its installed ABB ACS800 drive system.
  • Interfaces an analog resolver to ACS800 control
  • Returns motor-shaft speed and angle feedback
  • Supports 10 kHz or 20 kHz resolver excitation
  • Provides channel, initialization and error diagnostics

accurate motor-shaft speed and angular-position feedback The installation uses the manufacturer-specified host position, companion hardware and field/control wiring for the intended industrial application.

System commissioning includes identity checks, connection verification, controlled energization and functional diagnostics for RRIA-01.

Important Notice: Confirm the complete RRIA-01 marking, approved system arrangement, connection records and controlled functional test before commissioning or replacement.

Apter Power RRIA-01 Manuals and Guides
Apter Power RRIA-01 Product Technical Reference PDFABB RRIA-01 Resolver Interface Module User's Manual PDF
The first document organizes model-specific technical identity and engineering data. The second provides a separate field workflow for installation, connection checks and commissioning records.
ACS800 resolver-feedback commissioningACS800 RMIO option slot supports the engineered RRIA-01 arrangement.
Permanent-magnet motor shaft-position feedbackAIMA-01 I/O Module Adapter supports the engineered RRIA-01 arrangement.
AIMA-01 remote option-module installationShielded resolver cable supports the engineered RRIA-01 arrangement.
Drive speed-feedback fault tracingCompatible analog resolver supports the engineered RRIA-01 arrangement.
Read the applicable ABB installation instructions before work. Verify RRIA-01 and the installed-system configuration.
1Wait at least five minutes after isolating the ACS800 mains before handling RRIA-01.
2Confirm RRIA-01 is assigned to SLOT 1, SLOT 2 or the documented AIMA-01 node.
3Set resolver pole pairs and excitation frequency before refitting the enclosure cover.
4Earth resolver cable shields according to resolver isolation and motor grounding arrangement.
5Do not route resolver cable parallel to motor or other power cables.
6Confirm the 38-pin connector is fully inserted and both mounting screws are secured.
7Verify forward rotation produces positive resolver speed feedback before closed-loop release.
8Review CHA, CHB, WD/INIT and ERR indications during controlled startup.

Alternative Names

Alternative Names

3ABD68486408

Technical notes

Technical notes

Install RRIA-01 only in the documented ACS800 option slot or AIMA-01 adapter position, with resolver pole pairs and excitation frequency preserved. Verify positive feedback direction and review CHA, CHB, WD/INIT and ERR indications during controlled startup.

FAQS

  • Which host system accepts RRIA-01?
    Use RRIA-01 only with the documented ABB ACS800 drive hardware and software configuration.
  • What identity checks are required before installing RRIA-01?
    Match the full order number, hardware revision, slot assignment and companion components to the approved project record.
  • How should engineers isolate equipment before replacing RRIA-01?
    Apply the host-system shutdown procedure, isolate all stated power and signal sources, and verify the safe state before removal.
  • Which configuration data should be backed up before replacing RRIA-01?
    Preserve the documented hardware configuration, communication addresses, parameter values and diagnostic records applicable to this exact unit.
  • How should field or network connections for RRIA-01 be restored?
    Reconnect only the identified terminals and interfaces, maintaining the recorded shield, grounding, polarity and network arrangement.
  • Which startup checks apply to RRIA-01?
    Inspect mounting and connectors, restore the approved configuration, energize in a controlled sequence and review all product-specific diagnostics.
  • Can another resolver interface module replace RRIA-01 without project changes?
    A substitution requires an engineering comparison of order number, firmware, memory, interfaces, mechanical fit and project configuration.
  • What commissioning evidence should be retained for RRIA-01?
    Retain the as-found identity, as-left configuration, connection checks, diagnostic status and controlled functional-test result.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.