Match the complete marking
Include PR9268/601-000 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation. -
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered PR9268/601-000 reference with the installed equipment and applicable Emerson documentation.
Technical specifications for PR9268/601-000
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:PR9268/601-000
-
Weight:0.96 kg
-
Tariff Code:8537101190
-
Measurement orientation:Vertical, high-temperature
-
Selected cable:5 m armored cable
-
Selected cable end:Harting plug
-
Frequency range:10 to 1000 Hz
-
Sensitivity, pin 3:22.0 mV/(mm/s) +/-5% at 100 kohm load
-
Sensitivity, pin 1 or 4:16.7 mV/(mm/s) +/-5% at stated load
-
Natural frequency:8 Hz +/-1.5 Hz at 20 deg C
-
Operating temperature:-20 to +200 deg C
-
Protection class:IP65
-
Housing material:Stainless steel
-
Typical sensor weight:1050 g
-
Amplitude linearity:Less than 2%
-
Maximum acceleration:10 g continuous; 20 g intermittent
-
Coil resistance, pin 3:3270 ohm +/-10%
-
Inductance:160 mH maximum
Information
- This exact build is the short-lead member of the vertical 60x high-temperature group, useful where the sensor must tolerate hot case surfaces without an unnecessary eight- or ten-metre cable run.
Lead selection: Five-metre armored Harting assembly; codes 602 and 603 extend the same family to 8 m and 10 m.
Channel setting: Record output pin and receiving load because pin 3 and pins 1/4 use different loaded sensitivities.
Sensitivity depends on the selected output pin and load: pin 3 is documented at 22.0 mV/(mm/s), while pins 1 or 4 use 16.7 mV/(mm/s) under their stated loads. The wiring record therefore belongs with the sensor identity.
The five-metre armored cable and Harting plug define the physical route. A replacement with code 602 or 603 changes cable length even though the sensing element remains in the same high-temperature group.
-
Emerson PR9268/601-000 official technical excerpt
Selected manufacturer pages covering the applicable family, technical data and exact order-code fields. -
Emerson PR9268/601-000 engineering guide
Apter Power installation, configuration, diagnostic and acceptance guidance.
Platform applications: The uses below require the documented AMS PR9268 case-vibration measurement channel companion components and approved machine drawing.
-
Hot vertical bearing case
Use where the approved measurement point requires the 60x high-temperature element and a five-metre armored path. -
Steam-turbine casing
Keep the sensor vertical and verify that connector temperature remains within the installation boundary. -
Compressor hot section
Apply the correct pin/load sensitivity rather than treating every PR9268 output conductor as equivalent. -
Short local junction route
Select the 601 build when five metres reaches the Harting junction without leaving an unsupported cable coil.
The sensor family reaches 200 deg C, but the complete installation must also respect connector and cable limits.
Record whether the channel uses pin 3, pin 1 or pin 4 and apply the matching sensitivity and load.
Document any angular offset and the monitor configuration used to compensate within the permitted range.
A field splice changes the route and can compromise high-temperature and hazardous-area evidence.
Look for crushed convolutions, heat discoloration and loss of strain relief along the five-metre cable.
Compare channel filters and alarm logic with the high-temperature family response before release.
Alternative Names
Technical notes
Pin/load basis: Use 22.0 mV/(mm/s) only for pin 3 at the stated load; other pins use their own value.
High-temperature route: Keep the five-metre armor clear of hot edges and provide supports that permit thermal movement.
Angle compensation: Record the vertical offset and any configured sinking current rather than assuming zero correction.
FAQ View All FAQ
-
Why is the output pin important for PR9268/601-000?Its high-temperature coil has different documented sensitivities for pin 3 and for pins 1 or 4 at their stated loads.
-
What cable length distinguishes PR9268/601-000?Code 1 fixes the armored lead at 5 m, separating it from the otherwise similar 602 and 603 selections.
-
What frequency range belongs to PR9268/601-000?The vertical 60x high-temperature family is documented from 10 to 1000 Hz.
-
Which temperature statement applies to PR9268/601-000?The sensor family is specified from -20 to +200 deg C; cable, plug and installation limits still require review.
-
How should the vertical angle of PR9268/601-000 be checked?Measure the installed axis and reconcile any permitted offset with the receiving-card configuration and maintenance baseline.
-
Can PR9268/601-000 be replaced by PR9268/201-000 without review?No. The 201 build changes frequency floor, sensitivity, coil data, housing and maximum operating temperature.
-
What should be inspected on the Harting plug of PR9268/601-000?Check shell, insert, pins, backshell and cable strain relief before the channel is energized.
-
Which records close an exchange of PR9268/601-000?Retain the label, pin assignment, load, mounting angle, route photographs and returned machine-velocity trend.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.