Speak to a sourcing specialist
sales13@apterpower.com

PR6424/006-131 CON041

Eddy-Current Sensor
In Stock
Ships by Monday, November 9
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson PR6424/006-131 CON041 identifies a PR6424 16 mm eddy-current sensor paired with the CON041 signal-converter family. The documented PR6424 standard chain provides a ±2.0 mm static range and 4 V/mm sensitivity on 42CrMo4 steel.
Get a quick price for PR6424/006-131 CON041
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for PR6424/006-131 CON041

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    PR6424/006-131 CON041
  • Estimated shipping dimensions:
    18×16×3cm
  • Weight:
    0.35 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Sensor principle:
    Eddy current, non-contact
  • Sensor diameter:
    16 mm
  • Static range:
    ±2.0 mm
  • Recommended dynamic range:
    0 to 1000 µm peak-to-peak
  • Sensitivity:
    4 V/mm on 42CrMo4 steel
  • Nominal center air gap:
    Approximately 2.7 mm
  • Sensor operating temperature:
    -35 to +150 °C
  • Target material:
    Ferromagnetic steel; 42CrMo4 standard
  • Converter family:
    CON041 DIN-rail signal converter
  • Converter frequency range:
    0 to 20,000 Hz (-3 dB)
  • Standard converter range for PR6424:
    4.0 mm

Information

Overview Manuals Common Applications Product Precautions
Emerson PR6424/006-131 CON041 is handled as one calibrated sensor-converter chain whose probe identity, cable path, target material and converter pairing must remain together.
  • 16 mm non-contact eddy-current sensing
  • ±2.0 mm static measurement range
  • 4 V/mm sensitivity on 42CrMo4 steel
  • CON041 DIN-rail converter with 0-20 kHz response

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm PR6424/006-131 CON041, every companion marking and the recorded acceptance result before replacement.

Emerson PR6424/006-131 CON041 Manuals & Downloads
Emerson PR6424/006-131 CON041 Technical Reference (PDF)Emerson PR6424/006-131 CON041 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Exact-position replacement
Matches PR6424/006-131 CON041 to the recorded host, position and companion hardware before changeout.
Interface restoration
Rebuilds the documented power, signal, keying and protective interfaces for PR6424/006-131 CON041.
Configuration-controlled service
Restores assignments and settings from the approved record instead of borrowing them from a neighboring device.
Acceptance and handover
Confirms diagnostics and a controlled functional response from PR6424/006-131 CON041 before release.
Read the applicable product and site instructions before work. Verify PR6424/006-131 CON041, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete PR6424/006-131 CON041 marking and documented hardware role before work.
2
Place the connected process and controller hardware in the approved maintenance state.
3
Record the host position, companion parts, cable direction, terminal assignments and active configuration.
4
Isolate every documented power, signal and stored-energy source before disconnecting hardware.
5
Protect keyed connectors, electronic contacts and labeled field conductors during handling.
6
Restore only the recorded power, wiring, grounding, shielding and configuration arrangement.
7
Energize in a controlled sequence and review device, carrier, controller and field diagnostics.
8
Function-test non-contact measurement of shaft displacement, position, eccentricity or speed/key motion and retain the acceptance record before service release.

Technical notes

Use PR6424/006-131 CON041 only in the documented AMS Machinery Health Measurement Chain execution. Preserve complete identity, interfaces and configuration, then verify diagnostics and non-contact measurement of shaft displacement, position, eccentricity or speed/key motion under controlled conditions.

FAQ View All FAQ

  • What does Emerson PR6424/006-131 CON041 measure?
    It forms a non-contact eddy-current measurement chain for shaft displacement, position and vibration measurements on compatible ferromagnetic targets.
  • What sensor diameter applies to Emerson PR6424/006-131 CON041?
    The PR6424 sensor has a 16 mm sensing diameter.
  • What static range is specified for Emerson PR6424/006-131 CON041?
    The standard PR6424 chain provides a ±2.0 mm static measurement range.
  • What sensitivity applies to Emerson PR6424/006-131 CON041?
    The specified sensitivity is 4 V/mm on a 42CrMo4 steel target.
  • What center air gap is used with Emerson PR6424/006-131 CON041?
    The nominal center air gap is approximately 2.7 mm for the standard target material.
  • What temperature range applies to the PR6424 sensor in Emerson PR6424/006-131 CON041?
    The sensor operating range is -35 to +150 °C.
  • What is the CON041 role in Emerson PR6424/006-131 CON041?
    CON041 is the DIN-rail signal converter that conditions the PR6424 eddy-current sensor signal over a 0 to 20 kHz frequency range.
  • How should Emerson PR6424/006-131 CON041 be checked after installation?
    Verify the exact sensor, cable and converter pairing, target material, mechanical gap, bias condition and controlled displacement response before service release.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.