Match the complete marking
Include PR6423-10R-010-CON021 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered PR6423-10R-010-CON021 with the installed equipment and applicable Emerson documentation.
Technical specifications for PR6423-10R-010-CON021
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:PR6423-10R-010-CON021
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Product type:Eddy-current sensor with signal converter
-
Sensor reference:PR6423/10R-010
-
Converter:CON021
-
Sensor tip diameter:8 mm
-
Mounting configuration:Reverse mount; 3/8-24 UNF thread
-
Cable configuration:Unarmored; adapter plug; 5.0 m; LEMO cable end
-
Linear measurement range:2 mm, standard PR6423 measurement chain
-
Scale factor:8 V/mm ±5%, 0 to 45 °C
-
Reference target:42CrMo4 / AISI 4140 steel
-
Sensor protection:IP66
-
Converter protection:IP20
-
Converter frequency response:0 to 20 kHz (-3 dB)
-
Converter rise time:Less than 15 µs
-
Converter supply:-23 to -32 V for -4 to -20 V output; -21 to -32 V for -2 to -18 V output
-
Converter temperature:-30 to +100 °C
-
Sensor temperature:-35 to +180 °C including first 1 m cable
-
Cable and connector temperature:-35 to +150 °C
-
Converter connections:Self-locking LEMO sensor input; supply/output screw terminals, max. 1.5 mm²
Information
- PR6423-10R-010-CON021 forms a sensor-and-converter measurement chain, converting the distance to a conductive shaft target into a voltage signal for machinery monitoring.
Sensor configuration: 8 mm, reverse mount, 3/8-24 UNF
Measurement range: 2 mm with standard matched chain
Signal converter: CON021 panel-mount unit
The standard PR6423 chain provides a 2 mm linear measurement range. Its incremental scale factor is 8 V/mm ±5% over 0 to 45 °C, with 42CrMo4 / AISI 4140 steel as the reference target material. Shaft material and installed gap affect the measurement relationship, so final gap adjustment uses the output of the complete converter-and-sensor chain. The signal can support radial or axial shaft displacement, position and eccentricity measurement when the monitoring channel is configured for the intended task.
CON021 provides a 0 to 20 kHz frequency response at -3 dB and a rise time below 15 µs. It uses a negative DC supply: -23 to -32 V for a -4 to -20 V output range, or -21 to -32 V for a -2 to -18 V output range. The sensor input uses a self-locking LEMO connection and the supply/output uses screw terminals. The converter is IP20 and rated -30 to +100 °C, whereas the sensor is IP66; therefore the converter enclosure and probe environment require separate assessment.
-
Emerson PR6423-10R-010-CON021 technical reference
Official PR6423 and CON021 specifications excerpts. Sensor and converter ratings apply separately to the matched chain. PDF, 2 pages, 297.8 KB. -
Emerson PR6423-10R-010-CON021 installation guide
Prepared by Apter Power. Product-specific preparation, connection review, commissioning and functional acceptance. PDF, 5 pages, 26.3 KB.
Compatibility boundary: Confirm the reverse-mount arrangement, 5.0 m cable configuration, converter output range and target material. A shared sensor family does not establish interchangeability between different measurement chains.
-
Radial shaft vibration
Measure shaft motion relative to the probe mounting point. Position the sensor on a suitable conductive target track and configure the monitoring channel for radial displacement. -
Axial position
Use the static distance signal to monitor an appropriate axial target. Set the operating gap within the matched chain range and allow for expected shaft travel. -
Shaft eccentricity
Monitor changes in the shaft-to-probe gap during the intended operating condition. Target geometry, surface condition and material must suit the measurement. -
Turbomachinery monitoring
Integrate the sensor/converter chain with the selected machinery-monitoring input on turbines, compressors or pumps. Verify input scaling and channel purpose before commissioning.
Retain PR6423-10R-010-CON021, its cable option and converter marking. Changing a component can change the calibrated measurement relationship.
Use the PR6423/10R-010 reverse-mount arrangement and matching 3/8-24 UNF mounting thread. Avoid twisting the cable while positioning the sensor.
Provide strain relief and thermal-movement allowance. The unarmored cable requires a minimum bending radius of 25 mm; isolate the adapter connection as instructed.
The IP66 sensor does not make the IP20 converter weatherproof. Assess sensor, cable/connector and converter temperatures individually.
Match the CON021 negative DC supply and output range. Do not connect it as an ordinary positive 24 V device without checking the approved wiring.
Adjust the installed gap using the complete converter-and-sensor output. Confirm target material and measurement response before enabling the monitoring function.
Alternative Names
Technical notes
System relationship: Use the matched sensor, cable and converter adjusted for the target material. The standard PR6423 range is 2 mm.
Configuration boundary: Sensor configuration refers to PR6423/10R-010; converter ratings refer to CON021. Measurement performance requires a matched sensor, cable and converter adjusted for the target material. Sensor and converter environmental limits are different.
Technical reference: Emerson PR6423 Specifications Sheet, December 2024; CON021 Specifications Sheet, August 2017; PR 642x Installation Guide, MHM-97857 Rev 1.11, January 2026.
FAQ View All FAQ
-
What mounting configuration does PR6423-10R-010-CON021 use?PR6423/10R-010 uses an 8 mm sensor tip, a 3/8-24 UNF case thread and reverse mounting. R identifies reverse mount, not a different direction of thread.
-
What cable configuration belongs to PR6423-10R-010-CON021?The PR6423/10R-010 code specifies no armor, an adapter plug, the 5.0 m cable option and a LEMO cable end. Preserve the matched chain when replacing a cable or sensor.
-
What is the standard measuring range of PR6423-10R-010-CON021?The standard PR6423/CON021 chain has a 2 mm linear range. Extended-range CON021 variants have different identities and must not be assumed for this combination.
-
What target material is used to set up PR6423-10R-010-CON021?The reference material is 42CrMo4 / AISI 4140 steel. Another conductive material can change the measurement relationship and requires an appropriate adjustment.
-
What supply voltage does the CON021 in PR6423-10R-010-CON021 require?Use -23 to -32 V for a -4 to -20 V output range, or -21 to -32 V for a -2 to -18 V output range. Confirm the actual converter range and negative polarity.
-
What dynamic response applies to the converter in PR6423-10R-010-CON021?CON021 has a frequency response from DC to 20 kHz at -3 dB and a rise time below 15 µs. The installed monitoring chain must also support the required measurement bandwidth.
-
Do the sensor and converter in PR6423-10R-010-CON021 have the same environmental limits?No. The sensor is IP66 while CON021 is IP20. CON021 operates from -30 to +100 °C; sensor, cable and connector temperatures must be assessed separately.
-
How should the operating gap of PR6423-10R-010-CON021 be adjusted?Use the output of the complete matched sensor, cable and converter chain. Keep the target material and intended measurement range consistent with the configured monitoring channel.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.