Speak to a sourcing specialist
sales13@apterpower.com

PR6423-10R-010-CON021

Eddy Current Sensor
Ships by Friday, November 6
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson PR6423-10R-010-CON021 combines a reverse-mount 8 mm eddy-current sensor with a CON021 signal converter for non-contact shaft displacement measurement.
  • Manufacturer part number
    PR6423-10R-010-CON021
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    18cm x 18cm x 4cm
  • Country of Origin
    USA
Get a quick price for PR6423-10R-010-CON021
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete PR6423-10R-010-CON021 reference, label photos and required quantity.
  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents.
  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.
  • Match the complete marking

    Include PR6423-10R-010-CON021 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label, connector and mounting photos. Have your maintenance team compare the offered PR6423-10R-010-CON021 with the installed equipment and applicable Emerson documentation.

Technical specifications for PR6423-10R-010-CON021

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    PR6423-10R-010-CON021
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Product type:
    Eddy-current sensor with signal converter
  • Sensor reference:
    PR6423/10R-010
  • Converter:
    CON021
  • Sensor tip diameter:
    8 mm
  • Mounting configuration:
    Reverse mount; 3/8-24 UNF thread
  • Cable configuration:
    Unarmored; adapter plug; 5.0 m; LEMO cable end
  • Linear measurement range:
    2 mm, standard PR6423 measurement chain
  • Scale factor:
    8 V/mm ±5%, 0 to 45 °C
  • Reference target:
    42CrMo4 / AISI 4140 steel
  • Sensor protection:
    IP66
  • Converter protection:
    IP20
  • Converter frequency response:
    0 to 20 kHz (-3 dB)
  • Converter rise time:
    Less than 15 µs
  • Converter supply:
    -23 to -32 V for -4 to -20 V output; -21 to -32 V for -2 to -18 V output
  • Converter temperature:
    -30 to +100 °C
  • Sensor temperature:
    -35 to +180 °C including first 1 m cable
  • Cable and connector temperature:
    -35 to +150 °C
  • Converter connections:
    Self-locking LEMO sensor input; supply/output screw terminals, max. 1.5 mm²

Information

Overview Downloads Applications / Compatibility Product Precautions
  • PR6423-10R-010-CON021 forms a sensor-and-converter measurement chain, converting the distance to a conductive shaft target into a voltage signal for machinery monitoring.
Product type: Eddy-current sensor and converter
Sensor configuration: 8 mm, reverse mount, 3/8-24 UNF
Measurement range: 2 mm with standard matched chain
Signal converter: CON021 panel-mount unit
PR6423-10R-010-CON021 combines a PR6423/10R-010 sensor with a CON021 converter for non-contact shaft measurement. The sensor uses an 8 mm tip, a 3/8-24 UNF case thread and reverse mounting. Its configuration includes an unarmored cable, an adapter plug, a 5.0 m cable-length option and a LEMO cable end. The sensor and converter must form the correct adjusted measurement chain; the cable is part of that electrical arrangement.

The standard PR6423 chain provides a 2 mm linear measurement range. Its incremental scale factor is 8 V/mm ±5% over 0 to 45 °C, with 42CrMo4 / AISI 4140 steel as the reference target material. Shaft material and installed gap affect the measurement relationship, so final gap adjustment uses the output of the complete converter-and-sensor chain. The signal can support radial or axial shaft displacement, position and eccentricity measurement when the monitoring channel is configured for the intended task.

CON021 provides a 0 to 20 kHz frequency response at -3 dB and a rise time below 15 µs. It uses a negative DC supply: -23 to -32 V for a -4 to -20 V output range, or -21 to -32 V for a -2 to -18 V output range. The sensor input uses a self-locking LEMO connection and the supply/output uses screw terminals. The converter is IP20 and rated -30 to +100 °C, whereas the sensor is IP66; therefore the converter enclosure and probe environment require separate assessment.
Controller platform reference: Emerson PR6423 / CON021. Match the sensor, cable, converter and target material.
Technical downloads for Emerson PR6423-10R-010-CON021: original manufacturer technical information and an Apter Power installation verification guide.
The technical reference preserves selected manufacturer pages. The installation guide is compiled by Apter Power for preparation and review; apply the original operating procedures and site controls during work.
Match PR6423-10R-010-CON021 to the installed hardware and approved configuration before replacement or commissioning.
Preserve the complete chain

Retain PR6423-10R-010-CON021, its cable option and converter marking. Changing a component can change the calibrated measurement relationship.

Check reverse mounting

Use the PR6423/10R-010 reverse-mount arrangement and matching 3/8-24 UNF mounting thread. Avoid twisting the cable while positioning the sensor.

Protect cable and adapter

Provide strain relief and thermal-movement allowance. The unarmored cable requires a minimum bending radius of 25 mm; isolate the adapter connection as instructed.

Separate environmental limits

The IP66 sensor does not make the IP20 converter weatherproof. Assess sensor, cable/connector and converter temperatures individually.

Verify negative supply polarity

Match the CON021 negative DC supply and output range. Do not connect it as an ordinary positive 24 V device without checking the approved wiring.

Set the gap using the signal

Adjust the installed gap using the complete converter-and-sensor output. Confirm target material and measurement response before enabling the monitoring function.

Alternative Names

PR6423-10R-010-CON021 PR6423 10R 010 CON021 Emerson PR6423-10R-010-CON021 Emerson PR6423 10R 010 CON021

Technical notes

System relationship: Use the matched sensor, cable and converter adjusted for the target material. The standard PR6423 range is 2 mm.

Configuration boundary: Sensor configuration refers to PR6423/10R-010; converter ratings refer to CON021. Measurement performance requires a matched sensor, cable and converter adjusted for the target material. Sensor and converter environmental limits are different.

Technical reference: Emerson PR6423 Specifications Sheet, December 2024; CON021 Specifications Sheet, August 2017; PR 642x Installation Guide, MHM-97857 Rev 1.11, January 2026.

FAQ View All FAQ

  • What mounting configuration does PR6423-10R-010-CON021 use?
    PR6423/10R-010 uses an 8 mm sensor tip, a 3/8-24 UNF case thread and reverse mounting. R identifies reverse mount, not a different direction of thread.
  • What cable configuration belongs to PR6423-10R-010-CON021?
    The PR6423/10R-010 code specifies no armor, an adapter plug, the 5.0 m cable option and a LEMO cable end. Preserve the matched chain when replacing a cable or sensor.
  • What is the standard measuring range of PR6423-10R-010-CON021?
    The standard PR6423/CON021 chain has a 2 mm linear range. Extended-range CON021 variants have different identities and must not be assumed for this combination.
  • What target material is used to set up PR6423-10R-010-CON021?
    The reference material is 42CrMo4 / AISI 4140 steel. Another conductive material can change the measurement relationship and requires an appropriate adjustment.
  • What supply voltage does the CON021 in PR6423-10R-010-CON021 require?
    Use -23 to -32 V for a -4 to -20 V output range, or -21 to -32 V for a -2 to -18 V output range. Confirm the actual converter range and negative polarity.
  • What dynamic response applies to the converter in PR6423-10R-010-CON021?
    CON021 has a frequency response from DC to 20 kHz at -3 dB and a rise time below 15 µs. The installed monitoring chain must also support the required measurement bandwidth.
  • Do the sensor and converter in PR6423-10R-010-CON021 have the same environmental limits?
    No. The sensor is IP66 while CON021 is IP20. CON021 operates from -30 to +100 °C; sensor, cable and connector temperatures must be assessed separately.
  • How should the operating gap of PR6423-10R-010-CON021 be adjusted?
    Use the output of the complete matched sensor, cable and converter chain. Keep the target material and intended measurement range consistent with the configured monitoring channel.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.