Technical specifications for PR6423-002-030

  • Manufacturer:
    Emerson
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    PR6423-002-030
  • Estimated shipping dimensions:
    16x15x4cm
  • Weight:
    0.3 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Sensor family:
    PR6423
  • Sleeve thread:
    M10 x 1
  • Armor:
    No
  • Probe length Cx:
    45 mm
  • Overall sensor length C:
    54 mm
  • Adapter plug:
    Included
  • Total cable length:
    8 m
  • Cable end:
    LEMO
  • Static nominal range:
    +/-1.0 mm
  • Recommended dynamic range:
    50 to 500 um p-p
  • Sensitivity:
    8 V/mm
  • Nominal distance center:
    Approximately 1.5 mm
  • Basic air gap:
    0.4 to 0.7 mm
  • Operating temperature:
    -35 to +180 degC; +200 degC short term
  • Pressure at sensor head:
    10,000 hPa
  • Vibration endurance:
    5 g at 60 Hz

Information

Overview Manuals Common Applications Product Precautions
Emerson PR6423-002-030 is pr6423 8 mm eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
  • Uses an M10 x 1 metric sleeve
  • Provides an eight-metre unarmored lead
  • Measures over a two-millimetre nominal static span
  • Terminates in the documented LEMO connection

PR6423-002-030 operates with CON021 or CON041 signal converter, Conductive steel target, Probe mounting bracket, Compatible machinery-monitoring input.

Engineered applications include Radial shaft vibration, Axial thrust position, Shaft centerline trending, Eccentricity measurement.

Important Notice: Confirm the M10 x 1 mounting, 45 mm probe length, eight-metre loop and paired converter calibration; set gap only after the bracket is mechanically secure.

Apter Power PR6423-002-030 Manuals and Guides

Apter Power PR6423-002-030 Measurement-System Technical Reference PDFApter Power PR6423-002-030 Installation, Loop Check and Acceptance Workbook PDF

The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.

Radial shaft vibration

Tracks journal motion relative to the bearing housing.

Axial thrust position

Observes axial shaft displacement at a thrust collar.

Shaft centerline trending

Supports slow-roll and operating centerline analysis.

Eccentricity measurement

Captures once-per-turn shaft bow or eccentric motion.

Read the applicable Emerson machinery-monitoring instructions before work. Verify PR6423-002-030 and the installed Emerson PR6423 8 mm eddy-current measurement system configuration.
1

Verify the complete PR6423-002-030 order code, M10 x 1 mounting interface and assigned PR6423 8 mm eddy-current system measuring point before work.

2

Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6423-002-030.

3

Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.

4

Route the 8 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.

5

Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.

6

Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.

7

Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.

8

Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.

Technical notes

Confirm the M10 x 1 mounting, 45 mm probe length, eight-metre loop and paired converter calibration; set gap only after the bracket is mechanically secure.

FAQ View All FAQ

  • What measurement or system function does PR6423-002-030 perform?
    PR6423-002-030 is a pr6423 8 mm eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
  • Which installed hardware must be paired with PR6423-002-030?
    Use PR6423-002-030 with the documented Emerson PR6423 8 mm eddy-current measurement system components: CON021 or CON041 signal converter, Conductive steel target, Probe mounting bracket.
  • How should the Sensor family value for PR6423-002-030 be verified?
    Confirm the complete nameplate and order code before work; the documented sensor family is PR6423.
  • What connection detail is critical when installing PR6423-002-030?
    Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
  • How is PR6423-002-030 mechanically installed without changing measurement behavior?
    Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
  • What commissioning test should be completed for PR6423-002-030?
    Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
  • What configuration record should be retained when replacing PR6423-002-030?
    Retain the as-found position, sleeve thread, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
  • Can PR6423-002-030 replace a similar Emerson model without engineering review?
    No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved Emerson PR6423 8 mm eddy-current measurement system configuration.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.