IC695ALG728

HART Analog Output Module
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson IC695ALG728 is a hart analog output module. The module delivers analog commands and supports HART communication with compatible field devices.
  • Manufacturer part number
    IC695ALG728
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    3.5cm x 13.5cm x 13.5cm
  • Country of Origin
    USA
Get a quick price for IC695ALG728
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete IC695ALG728 reference, label photographs and required quantity. Include the installed interface and hardware revision.

  • 1

    Confirm the offer

    Review the offered IC695ALG728 execution, New, original product condition and itemized accessories against the retained application.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Compare the full Emerson IC695ALG728 marking, hardware execution and mating interfaces with the installed position before approving a replacement.

  • Check the offered item before ordering

    Request clear photographs of the offered IC695ALG728 marking and connections. Ask the maintenance team to compare them with the applicable Emerson instructions and the installed circuit or system design.

Technical specifications for IC695ALG728

  • Manufacturer:
    Emerson
  • Product Category:
    PLC Systems
  • Spare Part Number:
    IC695ALG728
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Output channels:
    8, non-isolated
  • Current output:
    0–20 mA or 4–20 mA
  • Voltage output:
    ±10 V or 0–10 V
  • External supply:
    19.2–30 V DC; 250 mA maximum
  • HART protocol:
    Version 5.0
  • Analog update:
    About 16 ms with HART; 8 ms without HART, all channels
  • Current load:
    850 Ω maximum at 20 V supply
  • Voltage load:
    2 kΩ minimum
  • Settling to 95%:
    70 ms current with HART; 23 ms without HART; 2 ms voltage

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Each channel uses its selected voltage or current range; HART data transfer is an additional communication function rather than a replacement for the analog command path.
Command path: configurable analog output to compatible field devices
Device communication: HART information alongside the current loop
Timing model: distinguish output refresh, settling and device polling
External field power connects directly to the module terminal block, not through the Universal Backplane TB1 connection. Current-output compliance depends on the supply and total circuit load. Thermal limits also depend on current-mode loading and ambient conditions.

Analog output refresh, output settling and HART variable acquisition have different timing. HART traffic is grouped and asynchronous to the analog scan. The application should distinguish a fresh analog command from a newly acquired digital device variable when supervising a final element.

Use the selected voltage range with a receiver whose load meets the output requirements. Validate the CPU and I/O path for supported HART pass-through to a monitoring station. Inspect field power, terminal-block seating and enabled-channel faults. Module readiness does not establish that every output circuit is healthy.
Controller platform reference: PACSystems RX3i. Use the applicable installation instructions and approved system design.
Apter Power technical reference for IC695ALG728, covering the verified interface and operating limits. Installation topics include: record final-element behavior; verify direct field power; check loop compliance.
The Apter Power technical reference and installation guide cover complementary engineering and service topics.
Prepare Emerson IC695ALG728 for its configured installation using these checks.
Record final-element behavior

Capture channel ranges, scaling and hold/default settings. Put actuators in their approved maintenance condition before disturbing output wiring.

Verify direct field power

Measure the external supply at the module terminal block and identify its return. Confirm that the source is not mistakenly routed only to backplane TB1.

Check loop compliance

Review the complete current-loop resistance and the expected minimum supply. Include any HART connection equipment and receiving-device requirements.

Exercise analog and digital paths

Test low, middle and high analog commands after allowing the applicable settling time. Separately check HART device identity and variable updates.

Verify fail-response settings

Test the approved controller-stop or communication-loss response with the process protected. Restore channel diagnostics and confirm the final element returns to commanded operation.

Control the return to service

Keep the affected process in its approved maintenance state until field indications and the intended control or monitoring response have both been checked.

Alternative Names

Emerson IC695ALG728

Technical notes

Configuration scope: Technical values apply to IC695ALG728 with the stated operating conditions. Check supplied revision and the configured installation.

Engineering acceptance: The intended hart analog output module function must be accepted with its actual mating interfaces and configured system. Review the complete current-loop resistance and the expected minimum supply. Include any HART connection equipment and receiving-device requirements.

FAQ View All FAQ

  • Why can an IC695ALG728 HART variable update more slowly than its analog output?
    HART acquisition is asynchronous and depends on device grouping, retries and requested variables. Do not use analog scan time as the digital-device update interval.
  • Can the RX3i backplane TB1 supply replace the direct field-power connection on IC695ALG728?
    No. The external supply must connect directly to this module terminal block. A powered backplane alone does not energize the analog output circuits.
  • How should loop resistance be assessed for IC695ALG728?
    Include the receiving device, wiring and any series equipment in the load total. Check compliance at the lowest field supply rather than only at nominal voltage.
  • Why does IC695ALG728 require a slower acceptance test when HART is enabled?
    Current-output settling is longer with HART enabled. Allow the specified settling interval before comparing a new command with a measured current.
  • Does IC695ALG728 need thermal review when several current outputs are loaded?
    Yes. Current-mode derating depends on supply voltage, load and active channels. Evaluate the actual combination rather than assuming eight channels always support the same ambient limit.
  • What should be checked if IC695ALG728 Field Status is amber but Module OK is green?
    Inspect field power, terminal-block seating and enabled-channel faults. Module readiness does not establish that every output circuit is healthy.
  • How can IC695ALG728 default-output settings affect a stopped controller?
    The configured hold/default behavior determines the command retained or applied during the relevant loss-of-control condition. Test that response against the final element’s safe process state.
  • Why should IC695ALG728 HART pass-through be validated at system level?
    It relies on a compatible CPU, I/O location and software communication path. A HART-capable output module alone does not establish end-to-end access from an asset-management station.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.