Match the complete marking
Include KJ3007X1-EA1-12P2413X032 and any series, revision or assembly markings. Keep the complete reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label, connector and mounting photos. Have your maintenance team compare the offered KJ3007X1-EA1-12P2413X032 with the installed equipment and applicable Emerson documentation.
Technical specifications for KJ3007X1-EA1-12P2413X032
-
Manufacturer:Emerson
-
Product Category:DCS Systems
-
Spare Part Number:KJ3007X1-EA1-12P2413X032
-
Weight:0.04 kg
-
Tariff Code:8537101190
-
Product type:PROFIBUS terminal block
-
Reference design:KJ3007X1-EA1
-
System family:DeltaV
-
Input power:5 V DC at 100 mA
-
Ambient temperature:-40 to +70 °C
-
Relative humidity:5 to 95%, non-condensing
-
Shock:10 g half-sine, 11 ms
-
Low-frequency vibration:1 mm peak-to-peak, 2 to 13.2 Hz
-
High-frequency vibration:0.7 g, 13.2 to 150 Hz
-
Airborne contaminants:ISA-S71.04-1985 Class G3
-
Insertion and removal:System power must be de-energized
-
Calibration:Not required
-
Field service:No user-serviceable parts; do not disassemble
Information
- The KJ3007X1-EA1 terminal block forms the field-connection point for a compatible PROFIBUS interface; installation and replacement must preserve the system power and hazardous-area requirements.
System family: DeltaV
Input rating: 5 V DC at 100 mA
Service method: De-energized insertion and removal
The terminal-block design supports an ambient temperature of -40 to +70 °C and 5 to 95% relative humidity without condensation. Its mechanical environment limits are a 10 g half-sine shock for 11 ms, 1 mm peak-to-peak vibration from 2 to 13.2 Hz, and 0.7 g vibration from 13.2 to 150 Hz. Airborne-contaminant suitability is Class G3 under ISA-S71.04-1985; these ratings do not replace the installation requirements for the complete system.
Insertion and removal require the system power to be de-energized. The terminal block has no user-serviceable parts and does not require calibration, so service should preserve the assembled unit rather than involve internal adjustment or disassembly. In hazardous locations, the actual product marking, applicable installation instructions and site classification must all agree before the equipment is returned to operation.
-
Emerson KJ3007X1-EA1-12P2413X032 technical reference
Original Emerson ATEX243 instruction sheet for KJ3007X1-EA1. Match the full assembly and actual unit marking. PDF, 1 pages, 303.5 KB. -
Emerson KJ3007X1-EA1-12P2413X032 installation guide
Prepared by Apter Power. Product-specific preparation, connection review, commissioning and functional acceptance. PDF, 5 pages, 26.2 KB.
Installation scope: The following contexts describe connection, environmental and service requirements. They do not establish compatibility with every DeltaV module or hazardous location.
-
PROFIBUS interface connections
Use the terminal block at its matching DeltaV interface. Compare the complete marking and terminal arrangement before reconnecting the field network. -
Control cabinet integration
Allow for the terminal-block ambient rating of -40 to +70 °C and non-condensing humidity. Assess the enclosure and adjacent equipment separately. -
Mechanical environment review
Assess both low-frequency displacement and higher-frequency acceleration. The separate vibration bands prevent one rating being applied across the entire frequency range. -
Hazardous-area replacement
Match the marked approval and site requirements before service. System power must be de-energized for terminal-block removal and insertion.
Retain KJ3007X1-EA1-12P2413X032 and the revision in the maintenance record. Do not infer interchangeability from the terminal-block family alone.
Do not insert or remove the block while system power is energized. Follow the approved isolation and return-to-service procedure.
There are no user-serviceable internal parts. Do not disassemble the terminal block or attempt an internal repair.
Maintain 5 to 95% relative humidity without condensation and assess cabinet conditions before energization.
Use 1 mm peak-to-peak for 2 to 13.2 Hz and 0.7 g for 13.2 to 150 Hz; assess shock separately at 10 g for 11 ms.
The installation must match the actual label and applicable hazardous-area requirements. A family reference does not certify every assembly or site configuration.
Alternative Names
Technical notes
System relationship: The reference input rating is 5 V DC at 100 mA. De-energize system power before inserting or removing the block.
Configuration boundary: These ratings apply to the KJ3007X1-EA1 terminal-block design. Match the complete KJ3007X1-EA1-12P2413X032 assembly marking, revision and installed interface before applying these limits; approvals depend on the marked unit and installation.
Technical reference: Emerson KJ3007X1-EA1 ATEX Instruction Sheet, ATEX243, November 2021.
FAQ View All FAQ
-
What is the function of KJ3007X1-EA1-12P2413X032?It is offered as a PROFIBUS terminal block for a compatible DeltaV interface. Compare the full assembly identity and terminal arrangement with the installed equipment.
-
What input rating applies to KJ3007X1-EA1-12P2413X032?The KJ3007X1-EA1 reference design is rated 5 V DC at 100 mA. Confirm applicability to the complete assembly marking before installation.
-
What ambient temperature applies to KJ3007X1-EA1-12P2413X032?The terminal-block reference rating is -40 to +70 °C. The complete installation may impose additional limits.
-
What humidity limit applies to KJ3007X1-EA1-12P2413X032?The reference limit is 5 to 95% relative humidity, non-condensing. Condensation is not covered by that rating.
-
How are the vibration limits for KJ3007X1-EA1-12P2413X032 specified?They are 1 mm peak-to-peak from 2 to 13.2 Hz and 0.7 g from 13.2 to 150 Hz. The separate shock limit is 10 g half-sine for 11 ms.
-
Can KJ3007X1-EA1-12P2413X032 be inserted with power on?No. System power must be de-energized before removal or insertion.
-
Does KJ3007X1-EA1-12P2413X032 require calibration or internal adjustment?Calibration is not required. The terminal block has no user-serviceable parts and should not be disassembled.
-
What must be checked before using KJ3007X1-EA1-12P2413X032 in a hazardous location?Match the actual unit marking, site classification and applicable installation instructions. Do not treat a terminal-block family reference as approval of the complete installation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.