Speak to a sourcing specialist
sales13@apterpower.com

KJ3002X1-BG2 12P1731X032

DeltaV Temperature Input Card
In Stock
Ships by Saturday, November 7
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Emerson KJ3002X1-BG2 12P1731X032 is retained as the complete supplied identity for a DeltaV temperature-input position. Manufacturer documentation defines KJ3002X1-BG2 as an eight-channel thermocouple and millivolt input card; X032-specific properties are not inferred.
Get a quick price for KJ3002X1-BG2 12P1731X032
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ3002X1-BG2 12P1731X032

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ3002X1-BG2 12P1731X032
  • Estimated shipping dimensions:
    4.1x12.5x10.5cm
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Documented base model:
    KJ3002X1-BG2
  • Input channels:
    8
  • Supported thermocouples:
    B, E, J, K, N, R, S and T
  • Additional input:
    Uncharacterized millivolt source
  • Conversion resolution:
    16 bit
  • LocalBus power:
    12 V DC at 350 mA maximum
  • Field circuit:
    5.5 V DC at 0.6 mA per channel
  • Diagnostic:
    Open-sensor detection
  • Operating temperature:
    -40 to 70°C
  • Storage temperature:
    -40 to 85°C
  • Relative humidity:
    5 to 95%, non-condensing
  • Airborne contaminants:
    ISA-S71.04-1985 G3

Information

Overview Manuals Common Applications Product Precautions
For temperature and low-level millivolt acquisition, KJ3002X1-BG2 digitizes eight isolated field channels and monitors open-sensor conditions. Sensor type, compensation method, polarity and terminal hardware must be reconciled with the installed loop schedule.
  • KJ3002X1-BG2 12P1731X032
  • KJ3002X1-BG2
  • 8
  • B, E, J, K, N, R, S and T

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm KJ3002X1-BG2 12P1731X032, every companion marking and the recorded acceptance result before replacement.

Emerson KJ3002X1-BG2 12P1731X032 Manuals & Downloads
Emerson KJ3002X1-BG2 12P1731X032 Technical Reference (PDF)Emerson KJ3002X1-BG2 12P1731X032 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Process-temperature measurement
Collects eight configured thermocouple or millivolt signals.
Mixed sensor planning
Associates each channel with its documented thermocouple type and range.
Open-sensor diagnostics
Reports an interrupted field circuit through the supported diagnostic path.
Cold-junction review
Retains the installed terminal and compensation arrangement during replacement.
Read the applicable product and site instructions before work. Verify KJ3002X1-BG2 12P1731X032, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete Emerson KJ3002X1-BG2 12P1731X032 marking against the receiving record before work.
2
Place the connected process, rack, machinery and control functions in the approved maintenance state.
3
Record the installed position, wiring, terminal hardware, settings and companion components before removal.
4
Isolate every affected electrical and process-energy source and verify the safe state.
5
Protect keyed connectors, terminals and electronics from contamination, strain and electrostatic damage.
6
Restore only the recorded wiring, grounding, shielding, settings and matched companion hardware.
7
Energize in the controlled sequence and review every available module, rack and system diagnostic.
8
Function-test eight-channel thermocouple and millivolt acquisition and retain the signed acceptance result before service release.

Technical notes

Evidence boundary: Official base-model evidence; complete item marking retained exactly. Use Emerson KJ3002X1-BG2 12P1731X032 only after the physical marking, installed position, terminal hardware and companion equipment have been reconciled.

FAQ View All FAQ

  • What is the documented purpose of Emerson KJ3002X1-BG2 12P1731X032?
    Emerson KJ3002X1-BG2 12P1731X032 is retained as the complete supplied identity for a DeltaV temperature-input position. Manufacturer documentation defines KJ3002X1-BG2 as an eight-channel thermocouple and millivolt input card; X032-specific properties are not inferred.
  • Which product family contains Emerson KJ3002X1-BG2 12P1731X032?
    The documented base model belongs to the DeltaV M-series product family.
  • Which function is documented for Emerson KJ3002X1-BG2 12P1731X032?
    For the documented base model, input channels is 8.
  • What channel or interface detail applies to Emerson KJ3002X1-BG2 12P1731X032?
    For the documented base model, supported thermocouples is B, E, J, K, N, R, S and T.
  • Which power boundary applies to Emerson KJ3002X1-BG2 12P1731X032?
    For the documented base model, additional input is Uncharacterized millivolt source.
  • Which environmental limit applies to Emerson KJ3002X1-BG2 12P1731X032?
    For the documented base model, conversion resolution is 16 bit.
  • What diagnostic or maintenance point applies to Emerson KJ3002X1-BG2 12P1731X032?
    For the documented base model, localbus power is 12 V DC at 350 mA maximum.
  • What should be verified after installing Emerson KJ3002X1-BG2 12P1731X032?
    Verify the complete marking, installed interfaces, retained settings, diagnostics and controlled operation of eight-channel thermocouple and millivolt acquisition before release.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.