Product Describe:

Emerson KJ2201X1-HA1 12P3322X022 is an SLS terminal block for the DeltaV SIS logic-solver hardware path. Its documented input power is 30 V DC and the unit cannot be removed or inserted while system power is energized.
Get a quick price for KJ2201X1-HA1 12P3322X022
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for KJ2201X1-HA1 12P3322X022

  • Manufacturer:
    Emerson
  • Product Category:
    DCS Systems
  • Spare Part Number:
    KJ2201X1-HA1 12P3322X022
  • Estimated shipping dimensions:
    8.3x12.5x10.5cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Hardware role:
    SLS terminal block
  • Platform:
    DeltaV SIS
  • Input power:
    30 V DC
  • Maximum current, A-B circuits:
    30 mA per channel
  • Maximum current, A-C circuits:
    1 A per channel
  • Ambient temperature:
    -40 to +70 °C
  • Relative humidity:
    5 to 95%, non-condensing
  • Shock:
    10 g half-sine wave for 11 ms
  • Vibration:
    1 mm peak-to-peak from 2 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz
  • Removal / insertion:
    Not permitted with system power energized
  • Calibration:
    Not required

Information

Overview Manuals Common Applications Product Precautions
Emerson KJ2201X1-HA1 12P3322X022 forms the keyed field-termination boundary for an SLS position, so terminal rows, channel conductors and the associated logic solver must remain matched.
  • DeltaV SIS SLS terminal-block function
  • 30 V DC input-power rating
  • -40 to +70 °C ambient operating range
  • No field calibration required

Retain the exact host position, connections and configuration record. Complete controlled diagnostics and a functional test before service release.

Important Notice: Confirm KJ2201X1-HA1 12P3322X022, every companion marking and the recorded acceptance result before replacement.

Emerson KJ2201X1-HA1 12P3322X022 Manuals & Downloads
Emerson KJ2201X1-HA1 12P3322X022 Technical Reference (PDF)Emerson KJ2201X1-HA1 12P3322X022 Installation & Commissioning Guide (PDF)

The technical reference consolidates product identity and interface data; the installation guide provides separate readiness, configuration, verification and handover checks.

Exact-position replacement
Matches KJ2201X1-HA1 12P3322X022 to the recorded host, position and companion hardware before changeout.
Interface restoration
Rebuilds the documented power, signal, keying and protective interfaces for KJ2201X1-HA1 12P3322X022.
Configuration-controlled service
Restores assignments and settings from the approved record instead of borrowing them from a neighboring device.
Acceptance and handover
Confirms diagnostics and a controlled functional response from KJ2201X1-HA1 12P3322X022 before release.
Read the applicable product and site instructions before work. Verify KJ2201X1-HA1 12P3322X022, the installed host and every connected interface before isolation or replacement.
1
Confirm the complete KJ2201X1-HA1 12P3322X022 marking and documented hardware role before work.
2
Place the connected process and controller hardware in the approved maintenance state.
3
Record the host position, companion parts, cable direction, terminal assignments and active configuration.
4
Isolate every documented power, signal and stored-energy source before disconnecting hardware.
5
Protect keyed connectors, electronic contacts and labeled field conductors during handling.
6
Restore only the recorded power, wiring, grounding, shielding and configuration arrangement.
7
Energize in a controlled sequence and review device, carrier, controller and field diagnostics.
8
Function-test termination of documented DeltaV SIS logic-solver field circuits and retain the acceptance record before service release.

Technical notes

Use KJ2201X1-HA1 12P3322X022 only in the documented DeltaV SIS execution. Preserve complete identity, interfaces and configuration, then verify diagnostics and termination of documented DeltaV SIS logic-solver field circuits under controlled conditions.

FAQ View All FAQ

  • What is Emerson KJ2201X1-HA1 12P3322X022?
    It is an SLS terminal block for the DeltaV SIS platform.
  • Which platform uses Emerson KJ2201X1-HA1 12P3322X022?
    The terminal block is intended for supported DeltaV SIS SLS hardware.
  • What input power applies to Emerson KJ2201X1-HA1 12P3322X022?
    The specified input-power rating is 30 V DC.
  • What current limit applies to the A-B circuits of Emerson KJ2201X1-HA1 12P3322X022?
    The A-B circuit limit is 30 mA per channel.
  • What current limit applies to the A-C circuits of Emerson KJ2201X1-HA1 12P3322X022?
    The A-C circuit limit is 1 A per channel.
  • Why must the full Emerson KJ2201X1-HA1 12P3322X022 identity be retained?
    The complete card and item-number marking controls the correct SLS terminal-block execution and prevents substitution by a similar-looking block.
  • What should be recorded before removing Emerson KJ2201X1-HA1 12P3322X022?
    Record the exact marking, host position, terminal assignments, connected circuits and protective measures before disconnection.
  • How should Emerson KJ2201X1-HA1 12P3322X022 be checked after installation?
    Verify the restored wiring, supply, channel diagnostics and required SIS proof-test response before service release.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.