Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for EQ3700DW
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for EQ3700DW

  • Manufacturer:
    DET-TRONICS
  • Product Category:
    General Automation
  • Spare Part Number:
    EQ3700DW
  • Estimated shipping dimensions:
    14.6×13.6×3.96cm
  • Weight:
    0.45 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Part number:
    007371-003
  • Module type:
    8-channel discrete input/output
  • Platform:
    Eagle Quantum Premier
  • Mounting code D:
    DIN rail
  • Approval code W:
    FM / CSA / ATEX / IECEx
  • Channel configuration:
    Input or output
  • Point style:
    Supervised or unsupervised
  • Input uses:
    Alarm, supervisory or other approved input
  • Output uses:
    Notification, releasing or approved control output
  • Field communication:
    EQP signaling line circuit
  • Enclosure material:
    Aluminum

Information

Overview Manuals Common Applications Product Precautions
Det-Tronics EQ3700DW expands an Eagle Quantum Premier fire-and-gas system with eight individually configurable discrete input or output channels and supervised or unsupervised point styles.
  • 8 configurable I/O channels
  • DIN-rail mounting
  • Supervised or unsupervised points
  • FM/CSA/ATEX/IECEx execution

Each channel can be assigned as an input or output and given an approved point style for alarm, supervisory, signaling or releasing service. The module communicates on the EQP signaling line circuit and reports individual active and fault conditions.

Important Notice: EQ3700DW is part number 007371-003. Preserve the D mounting code and W approval code; panel-mount or Russia-coded versions are different orderable executions.

Det-Tronics EQ3700DW Manuals & Downloads
Det-Tronics EQ3700DW Technical Reference (PDF)Det-Tronics EQ3700DW Manufacturer Manual Excerpt (PDF)

The technical reference organizes exact characteristics and engineering boundaries. The manufacturer excerpt presents selected unchanged official pages used for exact-model review.

Fire-detector inputs
Accepts approved heat, smoke or unitized flame-detector circuits.
Notification outputs
Operates configured alarm-signaling circuits within the engineered EQP design.
Releasing outputs
Controls approved releasing circuits through documented supervised logic.
Fire-and-gas system expansion
Adds eight field points to the Eagle Quantum Premier network.
Det-Tronics EQ3700DW installation checks: retain the exact identity, installed configuration and witnessed acceptance record throughout the work.
1
Confirm EQ3700DW and part number 007371-003 on the module label.
2
Export the eight channel types, point styles and EQP node configuration.
3
Place fire, gas and releasing functions in the approved impairment state.
4
Isolate field energy and notify responsible site personnel before wiring work.
5
Label every channel, shield, common and end-of-line device before removal.
6
Inspect DIN-rail mounting, grounding and signaling-line wiring.
7
Restore channel configuration and supervision values from the validated record.
8
Prove every input, output, active indication and fault response before release.

Technical notes

For EQ3700DW, retain the exact manufacturer identity, installed connection record and witnessed model-specific acceptance result.

FAQ View All FAQ

  • How many configurable channels does Det-Tronics EQ3700DW provide?
    It provides eight independent channels that can be configured as inputs or outputs.
  • Which mounting form is encoded by Det-Tronics EQ3700DW?
    The D code identifies DIN-rail mounting.
  • Which approval package is encoded by Det-Tronics EQ3700DW?
    The W code identifies the FM, CSA, ATEX and IECEx execution.
  • Which part number belongs to Det-Tronics EQ3700DW?
    The official product catalog lists part number 007371-003.
  • Can each channel on Det-Tronics EQ3700DW be supervised?
    Each point can be configured for supervised or unsupervised operation within the supported EQP point styles.
  • Which system communicates with Det-Tronics EQ3700DW?
    The module is designed for the Eagle Quantum Premier fire-and-gas system signaling line circuit.
  • What must be retained before replacing Det-Tronics EQ3700DW?
    Retain node identity, all eight channel assignments, supervision values, wiring labels and the impairment record.
  • What proves successful commissioning of Det-Tronics EQ3700DW?
    Witness every configured input and output together with active, fault, supervision and system-annunciation behavior.
Manufacturers

You May Also Like

Explore related automation components available through Apter Power.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.