Speak to a sourcing specialist
sales13@apterpower.com

990-05-70-01-05

Vibration Transmitter
Ships by Sunday, November 29
Bently Nevada 990-05-70-01-05 vibration transmitter, angled front view with terminal block and label
Bently Nevada 990-05-70-01-05 vibration transmitter, angled view of black mounting plate
Bently Nevada 990-05-70-01-05 vibration transmitter, close-up of front nameplate and terminals
Bently Nevada 990-05-70-01-05 vibration transmitter, angled front view with terminal block and label
Bently Nevada 990-05-70-01-05 vibration transmitter, angled view of black mounting plate
Bently Nevada 990-05-70-01-05 vibration transmitter, close-up of front nameplate and terminals
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 990-05-70-01-05 is a two-wire loop-powered transmitter that converts a matched 7 m NSv probe signal into 4–20 mA for a 0–5 mil peak-to-peak vibration range.
  • Manufacturer part number
    990-05-70-01-05
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    9.8cm x 7.4cm x 5.8cm
  • Country of Origin
    USA
Get a quick price for 990-05-70-01-05
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete Bently Nevada 990-05-70-01-05 reference, label photographs and required quantity. Match 990-05-70-01-05, range, 7 m chain and DIN mounting.

  • 1

    Confirm the offer

    Review the offered revision, condition, included items and documents against the confirmed installation.

  • 2

    Arrange dispatch

    Confirm quantity, dispatch date, lead-time start and delivery details in the quotation.

  • Match the complete marking

    Provide the complete Bently Nevada 990-05-70-01-05 marking. Match 990-05-70-01-05, range, 7 m chain and DIN mounting.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 990-05-70-01-05 with the installed equipment and applicable Bently Nevada instructions.

Technical specifications for 990-05-70-01-05

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    990-05-70-01-05
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Full-scale vibration:
    0–5 mil pp (ordering range: 0–125 µm pp)
  • NSv system length:
    7 m
  • Loop output:
    4–20 mA, two wire
  • Terminal supply:
    +12 to +35 V DC
  • Maximum loop resistance:
    1,000 Ω at 35 V DC
  • Loop accuracy:
    ±1.5% FS from TEST input, additional to probe scale-factor error
  • Typical current limit:
    23 mA
  • Not OK output:
    <3.6 mA
  • Startup inhibit:
    2–3 s
  • PROX OUT impedance:
    10 kΩ, calibrated for 10 MΩ load
  • Mounting:
    35 mm DIN-rail clips
  • Transmitter temperature:
    −35 to +85 °C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 990-05-70-01-05 presents overall shaft-vibration amplitude to a machinery controller while retaining a separate dynamic diagnostic output for suitable test equipment.
Amplitude range: 0–5 mil peak-to-peak
Signal: Two-wire 4–20 mA loop
Conditioning: Integrated NSv Proximitor function
The selected full scale is 0–5 mil peak-to-peak, shown as 0–125 µm peak-to-peak in the ordering range. The 70 system-length selection requires a matched 7 m NSv probe/cable chain, and the 01 mounting option provides 35 mm DIN-rail clips.

The transmitter accepts +12 to +35 V DC at its terminals and produces the proportional 4–20 mA loop signal. Maximum loop resistance is 1,000 ohms at 35 V DC; lower available voltage reduces the permissible loop burden.

An integrated Proximitor function removes the need for a separate conditioner. PROX OUT is a non-isolated dynamic signal, distinct from the overall loop value. A Not OK condition forces the loop below 3.6 mA, and startup includes a 2–3-second inhibit period.
Controller platform reference: 990 NSv vibration-transmitter channel. Match the installed configuration and applicable instructions.
Bently Nevada 990-05-70-01-05: original manufacturer technical information covering the specified interfaces and operating limits. Installation topics include: match the 7 m nsv chain, check din-rail retention, verify the normal probe gap, use test input for loop checks, verify fault and recovery behavior.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: Bently Nevada 990-05-70-01-05 operates within the following defined system context. Match 990-05-70-01-05, range, 7 m chain and DIN mounting.

Application scope: The applications below describe its technical role. Select associated hardware and configuration for the actual installation.
Prepare Bently Nevada 990-05-70-01-05 for its configured installation using these checks.
Retain peak-to-peak scaling

Configure the controller input for the 0–5 mil peak-to-peak range. Do not treat the loop value as RMS vibration or an instantaneous waveform.

Calculate the loop burden

Measure the available supply and total receiver/cable resistance. The 1,000-ohm maximum is associated with 35 V DC and must not be applied at a lower voltage without calculation.

Allow the startup inhibit

Observe the initial Not OK output for the expected 2–3 seconds. Investigate a persistent low-current state rather than masking it in the controller logic.

Isolate dynamic test equipment

Use the applicable test adapter when connecting grounded AC-powered instruments to PROX OUT. Preserve the isolation of the machinery loop during diagnostic work.

Retain the amplitude-channel record

Save the 7 m chain identity, loop supply and burden, scaling, startup behavior and diagnostic connection method. Release only after normal and fault indications are both understood.

Verify fault and recovery behavior

Under an approved maintenance condition, check the expected Not OK indication and recovery. Confirm that the controller distinguishes a fault current from a valid low-vibration reading.

Alternative Names

Bently Nevada 990-05-70-01-05 990 05 70 01 05

Technical notes

Operating boundary: Overall loop amplitude and PROX OUT serve different measurement purposes. The loop cannot replace a phase-capable dynamic monitoring channel.

Integration details: Preserve the full-scale range, 7 m chain, loop burden, DIN mounting and test-equipment isolation during replacement.

Technical basis: Bently Nevada 990 Vibration Transmitter, 141612 Rev. Y. 990-05-70-01-05 selects 0–5 mil pp, a 7 m NSv system and DIN-rail mounting. Electrical accuracy conditions apply to the matched probe chain and stated loop test arrangement.

FAQ View All FAQ

  • What vibration quantity does the 4–20 mA signal from 990-05-70-01-05 represent?
    It represents overall peak-to-peak vibration amplitude over the selected 0–5 mil range, not the instantaneous dynamic waveform.
  • Can 990-05-70-01-05 use an arbitrary 5 m probe chain?
    No. The 70 selection requires the matched 7 m NSv system arrangement.
  • Does 990-05-70-01-05 require an external Proximitor conditioner?
    No. Its Proximitor function is integrated; use the compatible probe and extension arrangement specified for the transmitter.
  • Why can 990-05-70-01-05 show less than 3.6 mA just after power-up?
    The startup inhibit holds the output in the Not OK region for approximately 2–3 seconds while the transmitter becomes ready.
  • How should an AC-powered analyzer be connected to 990-05-70-01-05?
    PROX OUT is not isolated from the loop. Use the applicable 990/991 test adapter for isolation rather than connecting grounded test equipment directly.
  • Is the 1,000-ohm loop limit of 990-05-70-01-05 valid at every supply voltage?
    No. That maximum is specified at 35 V DC. The available voltage and the complete loop burden must be assessed together.
  • Does ±1.5% loop accuracy describe the total probe-to-controller accuracy of 990-05-70-01-05?
    No. It is the TEST-input-to-loop accuracy under the specified test conditions and is additional to the probe output scale-factor error.
  • Can the 4–20 mA output of 990-05-70-01-05 provide vibration phase information?
    No. The overall amplitude signal does not preserve phase or the dynamic waveform. Use the suitable diagnostic output and equipment for that purpose.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.