Bently
View products
Sensor mounting stiffness, cable shielding and monitor input configuration affect the measured vibration signal. The -00 suffix remains part of the requested identity without assigning an unsupported option meaning.
Important Notice: Prepare a clean, rigid mounting surface for the 1/4-28 sensor interface. Compare the installed vibration response with a controlled reference before release.
The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.