Match the complete marking
Compare the full Bently Nevada 330851-02-000-070-90-00-CN marking and selected configuration with the installed component before accepting a replacement.
-
Check the offered item before ordering
Request clear label and connector photographs of Bently Nevada 330851-02-000-070-90-00-CN. Ask your maintenance team to compare the offered unit with the installed equipment and the applicable Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M before ordering.
Technical specifications for 330851-02-000-070-90-00-CN
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330851-02-000-070-90-00-CN
-
Weight:0.54 kg
-
Tariff Code:8537101190
-
Transducer family:3300 XL 25 mm
-
Mounting thread:M30×2
-
Overall case length:70 mm
-
Unthreaded-length selection:0 mm
-
Total probe lead:9.0 m
-
Lead armor:None
-
Probe resistance, center to outer:8.8 ± 1.1 Ω
-
Probe tip / case material:PEEK / AISI 304 stainless steel
-
Cable construction:75 Ω triaxial, PFA-insulated FluidLoc
-
Nominal scale factor:0.787 V/mm nominal
-
Nominal linear range:12.7 mm under specified calibration conditions
-
Probe continuous temperature:-35 to +200 °C
Information
- Bently Nevada 330851-02-000-070-90-00-CN carries a collar-displacement signal along its nine-metre integral lead to a remote conditioner. Its 70 mm threaded body provides mechanical reach without changing the required nine-metre electrical match.
Integral lead: 9.0 m unarmored FluidLoc cable
Matched-system output: 0.787 V/mm nominal
The 9 m probe lead must be treated as part of the corresponding 9 m calibrated system, not extended as though it were the 1 m version. Its disconnected center-to-outer-conductor resistance is 8.8 ± 1.1 Ω. The Proximitor Sensor provides the electrical excitation and conditioned output; the probe is not a stand-alone voltage transmitter.
For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
330851-02-000-070-90-00-CN Original Technical Excerpt
Original Bently Nevada pages explain the 25 mm sensing system, calibrated response, materials and applicable cable options. PDF · 6 pages.330851-02-000-070-90-00-CN Installation & Verification Guide
Apter Power field guide covering long-lead integrity, connector protection and displacement verification. PDF · 5 pages.
Application scope: Differential-expansion performance depends on the collar or ramp geometry, target material and configured channel arrangement. Mechanical fit alone does not establish electrical or calibration compatibility.
Long-lead integrity
Keep the 9 m probe lead intact, route the excess without sharp bends and use the matching 9 m conditioner arrangement.Turbine collar observation
Measure differential rotor-to-casing growth with a correctly aligned and gapped matched transducer chain.Complementary DE channels
Use opposing collar faces only with the intended two-channel arrangement and corresponding monitor configuration.Controlled displacement verification
Move the probe mounting relative to the target and compare the electrical indication with a mechanical movement reference.
The 9 m probe lead must be treated as part of the corresponding 9 m calibrated system, not extended as though it were the 1 m version.
Keep the high-temperature ClickLoc connector clean, finger tight and inside its connector protector.
Use the intended collar or ramp surface and verify the target material against the calibration.
Do not apply probe-body tightening torque to the electrical connector; connector maximum is 0.565 N·m.
Apply probe, cable and Proximitor Sensor temperature limits separately; avoid treating short-term exposure as continuous service.
Test the complete channel through controlled relative movement before restoring the machine protection function.
Alternative Names
Technical notes
Electrical relationship: The 9 m probe lead must be treated as part of the corresponding 9 m calibrated system, not extended as though it were the 1 m version. Its disconnected center-to-outer-conductor resistance is 8.8 ± 1.1 Ω. The Proximitor Sensor provides the electrical excitation and conditioned output; the probe is not a stand-alone voltage transmitter.
Measurement boundary: For the complete matched system, nominal sensitivity is 0.787 V/mm and the linear range is 12.7 mm. The reference conditions include a -24 Vdc supply, a 10 kΩ load, a Bently Nevada AISI 4140 steel target at least 61 mm in diameter, a 7 mm gap and component temperatures from 0 to +45 °C. Probe survivability to +200 °C does not make these reference accuracy conditions universal.
Technical reference: Bently Nevada 3300 XL 25 mm Proximity Transducer System, 163236 Rev. M.
FAQ View All FAQ
-
Why does the nine-metre version of 330851-02-000-070-90-00-CN need its own matching conditioner?Its integral 9.0 m lead defines the electrical-length selection. Use the corresponding 9 m 3300 XL 25 mm Proximitor Sensor; a conditioner chosen for a different total length does not preserve calibration.
-
How is the 70 mm case length of 330851-02-000-070-90-00-CN separated from measurement travel?The 70 mm dimension is mechanical reach of the M30×2 body. The matched system has a nominal 12.7 mm linear range under the specified calibration conditions, independent of that case length.
-
Can spare lead on 330851-02-000-070-90-00-CN be cut away after routing?No. Retain the calibrated lead and arrange excess cable without sharp bends or abrasion. The minimum bend radius is 25.4 mm, and the connector should remain protected and accessible.
-
What resistance indicates an intact long lead on 330851-02-000-070-90-00-CN?The isolated 9.0 m probe path is 8.8 ± 1.1 Ω from centre to outer conductor. Do not apply the lower 1 m probe resistance or include other connected components in that measurement.
-
Where should supply voltage be checked when the range of 330851-02-000-070-90-00-CN seems limited?Check the Proximitor Sensor terminals under load. Operation more positive than -23.5 Vdc can reduce the system linear range; the passive probe itself does not receive a separate DC transmitter supply.
-
Which nominal output interval corresponds to the calibrated gap of 330851-02-000-070-90-00-CN?For the matched system under reference conditions, approximately 0.63–13.33 mm corresponds to about -1.5 to -11.5 Vdc. These are conditioned-system values, not voltage generated directly by the bare probe.
-
How does receiving-channel loading affect verification of 330851-02-000-070-90-00-CN?Reference performance uses a 10 kΩ load and the Proximitor Sensor has 50 Ω output resistance. Evaluate the receiving input and field wiring together before comparing measured output with the nominal scale factor.
-
Can 330851-02-000-070-90-00-CN extend an existing 7200 measurement chain by changing only the probe?No. Conversion from 7200 or 25 mm DE Integral equipment requires the probe, extension cable where used, and Proximitor Sensor to be selected as a matched 3300 XL 25 mm system.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.