Speak to a sourcing specialist
sales13@apterpower.com

330103-00-13-05-02-00

3300 XL 8 mm proximity probe
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 330103-00-13-05-02-00 is a M10 x 1 forward mount sensing element with a 0.5 m lead for a matched 3300 XL 8 mm eddy-current measurement chain.
  • Manufacturer part number
    330103-00-13-05-02-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    1.8cm x 1.5cm x 67cm
  • Country of Origin
    USA
Get a quick price for 330103-00-13-05-02-00
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full marking, quantity and label photos. We review the item and any version details that need clarification.
  • 1

    Confirm the offer

    Check the quoted reference, condition, included items and expected dispatch date before approving your order.
  • 2

    Arrange dispatch

    Confirm delivery details and receive the tracking number when it becomes available.
  • Match the complete marking

    Include 330103-00-13-05-02-00 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
  • Check the offered item before ordering

    Request available label and interface photos. Have your maintenance team compare the offered 330103-00-13-05-02-00 reference with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 330103-00-13-05-02-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    330103-00-13-05-02-00
  • Weight:
    0.1 kg
  • Tariff Code:
    8537101190
  • Probe family:
    3300 XL 8 mm
  • Mounting thread:
    M10 x 1
  • Mounting form:
    forward mount
  • Cable armor:
    No armor
  • Unthreaded length:
    0 mm
  • Overall case length:
    130 mm
  • Total probe length:
    0.5 m
  • Connector and cable:
    Miniature coaxial ClickLoc, standard cable
  • Approval selection:
    Not required
  • Nominal probe resistance:
    7.45 +/-0.50 ohm
  • Matched-system linear range:
    2.0 mm (80 mil)
  • Matched-system scale factor:
    7.87 V/mm (200 mV/mil)
  • Recommended radial gap:
    Approximately 1.27 mm at -9 V DC
  • Matched-system frequency response:
    0 to 10 kHz, +0/-3 dB
  • Minimum flat target diameter:
    15.2 mm
  • Probe cable impedance:
    75 ohm triaxial
  • Probe tip material:
    PPS
  • Probe case material:
    AISI 303 or 304 stainless steel
  • Minimum cable bend radius:
    25.4 mm
  • Standard probe temperature:
    -52 to +177 deg C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 330103-00-13-05-02-00 is a M10 x 1 forward mount sensing element with a 0.5 m lead for a matched 3300 XL 8 mm eddy-current measurement chain.
Selected mechanics: M10 x 1; 0 mm unthreaded reach; 130 mm case; forward mount.
Lead interface: 0.5 m; Miniature coaxial ClickLoc, standard cable.
Matched response: 2.0 mm range, 7.87 V/mm scale and 0 to 10 kHz response for the complete approved chain.
The M10 x 1 forward mount body, 0 mm reach and 130 mm case set the sensing face relative to the target. These dimensions must agree with the installed port and recorded mechanical datum.

The 0.5 m lead uses miniature coaxial clickloc, standard cable. Its electrical length, connector condition and cable support are part of the calibrated probe-extension-Proximitor relationship.

The published 2.0 mm range and 7.87 V/mm scale are system values on the stated AISI 4140 reference target. Acceptance therefore includes the installed target, restored gap or bias and controlled monitor response.
Controller platform reference: 3300 XL 8 mm system. Verify the 130 mm port datum.
Technical downloads for Bently Nevada 330103-00-13-05-02-00: model-specific technical reference and installation review.
Use the exact order code and installed configuration when applying either document.
Prepare Bently Nevada 330103-00-13-05-02-00 using the approved machine documentation and site procedure.
Protect the probe face

Keep the PPS tip free of impact, metal chips and process contamination during handling and installation.

Control thread engagement

Seat the M10 x 1 body only to the documented datum; excessive engagement can bind the case or move the sensing face.

Preserve the lead

Maintain at least 25.4 mm bend radius, support the 0.5 m lead independently and never use the ClickLoc joint as a pulling point.

Inspect the connector

Keep the gold-plated interface clean and dry, align it fully and use the documented finger-tight connection method.

Restore the gap

Use the approved stopped-machine procedure to restore the recorded gap or bias before commissioning.

Prove the complete chain

Compare the Proximitor output and monitor indication with the accepted machine baseline before return to service.

Alternative Names

Bently Nevada 330103-00-13-05-02-00 3300 XL 8 mm proximity probe 330103-00-13-05-02-00

Technical notes

Mechanical fit: Use the M10 x 1 forward mount geometry with 0 mm reach and 130 mm case; do not substitute a different reach or case length.

Electrical chain: Place the 0.5 m probe lead only in the matching 3300 XL 8 mm total-length configuration and preserve the selected connector style.

Acceptance datum: Record the as-found gap or bias, restore the approved operating point and compare the returned channel response with the machine baseline.

FAQ View All FAQ

  • How is port depth checked for the 130 mm case of 330103-00-13-05-02-00?
    Measure usable threaded depth and internal clearance, then confirm that the long case reaches the target datum without bottoming or obstructing travel.
  • Why must the 0.5 m lead of 330103-00-13-05-02-00 be recorded?
    It determines the remaining extension-cable length required by the installed Proximitor option and cannot be changed independently.
  • How should the M10 mounting of 330103-00-13-05-02-00 be secured?
    Use the approved lock arrangement and torque method while monitoring the gap so tightening does not shift the sensing face.
  • What can create an incorrect gap with 330103-00-13-05-02-00?
    Wrong port datum, case bottoming, target runout, thread debris or cable load can move the probe from the recorded operating point.
  • How is the standard ClickLoc joint of 330103-00-13-05-02-00 checked?
    Inspect clean dry contacts, mate finger-tight, support the lead and confirm stable bias during a gentle connector and cable movement check.
  • How should the no-approval suffix of 330103-00-13-05-02-00 be reviewed?
    Verify the installation does not require an approval option from another suffix and retain the delivered label in the release record.
  • What proves the channel after fitting 330103-00-13-05-02-00?
    Restore the recorded bias and compare controlled target movement, Proximitor output and monitor indication with the baseline.
  • What evidence should be retained for 330103-00-13-05-02-00?
    Keep marking photos, port depth, thread datum, companion identities, as-left bias and controlled response results.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.