Product Describe:

Bently Nevada 3300/55-01-04-18-18-00-00-05-00 is a two-channel velocity monitor configured for 100 mV/in/s Velomitor inputs and 0–20 mm/s RMS ranges on both channels. It uses epoxy-sealed alarm relays without a safety barrier, agency-approval option or trip multiplier.
Get a quick price for 3300/55-01-04-18-18-00-00-05-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3300/55-01-04-18-18-00-00-05-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/55-01-04-18-18-00-00-05-00
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Measurement function:
    dual-channel machinery casing vibration
  • Channel count:
    2 independent online channels
  • Selected channel ranges:
    Channel A 0–20 mm/s RMS; Channel B 0–20 mm/s RMS
  • Selected transducer sensitivity:
    Velomitor, 100 mV/in/s
  • Unfiltered Velomitor frequency response:
    3–3000 Hz, -3 dB nominal
  • High-pass corner selection:
    3–400 Hz
  • Low-pass corner selection:
    24–3000 Hz
  • Recorder output selections:
    4–20 mA; 1–5 Vdc; 0 to -10 Vdc
  • Current-output load:
    0–600 Ω
  • Alarm setpoint range:
    0–100% of full scale
  • Alarm relay option:
    epoxy-sealed

Information

Overview Manuals Common Applications Product Precautions
Within a 3300 rack, Bently Nevada 3300/55-01-04-18-18-00-00-05-00 conditions two casing-vibration inputs through field-selectable filtering and presents each channel on its own 0–20 mm/s RMS scale.
  • Provides two independent online machinery-vibration channels.
  • Uses 100 mV/in/s Velomitor input sensitivity.
  • Selects 0–20 mm/s RMS for Channel A and Channel B.
  • Uses epoxy-sealed alarm relays with the base range and no safety barrier.

The transducer sensitivity, filter corners, RMS range, recorder scaling and alarm settings form one measurement chain. A stable display is not sufficient evidence of correct scaling; each channel should be checked with a controlled vibration or electrical test condition.

Important Notice: Match the complete 3300/55-01-04-18-18-00-00-05-00 marking, rear interface and both channel assignments before installation, then prove indication, recorder output and alarm response independently.

Bently Nevada 3300/55-01-04-18-18-00-00-05-00 Manuals & Downloads
Bently Nevada 3300/55-01-04-18-18-00-00-05-00 Technical Reference (PDF)Bently Nevada 3300/55-01-04-18-18-00-00-05-00 Installation & Commissioning Guide (PDF)

The technical reference, installation guide and complete product-information PDF have different scopes and apply only to the exact model shown.

Bearing-housing vibration
Monitor RMS casing velocity where rotor vibration is transmitted to the measurement point.
Two-channel machine protection
Apply identical RMS ranges to two identified locations while keeping the channels independent.
Filtered velocity monitoring
Select high-pass and low-pass corners for the useful machine response band.
Remote vibration recording
Send each proportional channel output to a compatible current or voltage receiver.
Apply these checks to the exact Bently Nevada 3300/55-01-04-18-18-00-00-05-00 measurement path before isolation, replacement or release.
1
Confirm the full Bently Nevada 3300/55-01-04-18-18-00-00-05-00 marking before removal.
2
Record both 0–20 mm/s RMS readings and the selected filter corners before isolation.
3
Retain the 100 mV/in/s Velomitor input sensitivity and channel polarity.
4
Verify that the transducer mounting point faithfully transmits machine vibration.
5
Restore the unbarriered rear interface selected by the order code.
6
Test the epoxy-sealed Alert and Danger relay contacts with the downstream circuit.
7
Confirm the recorder mode and receiving load for each channel.
8
Remove temporary bypasses only after both measurement and alarm paths pass the acceptance test.

Technical notes

Verify the 100 mV/in/s input sensitivity, 0–20 mm/s RMS spans, selected high-pass and low-pass corners, recorder mode, alarm setpoints, delays, reset behavior and epoxy-sealed relay contacts before returning both channels to service.

FAQ View All FAQ

  • Which measurement span is selected for both channels of Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    Channel A and Channel B each use a 0–20 mm/s RMS range. Recorder scaling and alarm thresholds should be checked against that RMS span.
  • Why must the 100 mV/in/s sensitivity be retained on Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    The selected input is intended for a 100 mV/in/s Velomitor signal. A different sensitivity can produce a plausible indication with an incorrect vibration value.
  • How are filter corners applied in Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    High-pass and low-pass corners are selected with plug-in jumpers. The chosen band must suit the machine response and remain consistent on both the local and recorder paths.
  • What does the RMS range change in Bently Nevada 3300/55-01-04-18-18-00-00-05-00 commissioning?
    The applied test and receiving recorder must be compared with RMS velocity units rather than peak velocity or peak-to-peak displacement units.
  • Which alarm relay hardware is fitted to Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    The selected relay option is epoxy-sealed. Its contact energization, Alert and Danger assignments and downstream wiring still require a functional test.
  • Does Bently Nevada 3300/55-01-04-18-18-00-00-05-00 include a safety barrier or range multiplier?
    No. The order code selects an unbarriered input interface and the base displayed range without 2X or 3X multiplication.
  • Which recorder interfaces can be checked on Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    The monitor supports individually scaled recorder outputs for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc. The connected receiver must match the selected mode and load condition.
  • What acceptance test should complete installation of Bently Nevada 3300/55-01-04-18-18-00-00-05-00?
    Apply a known condition to one channel at a time and compare the RMS display, buffered or recorder signal, Alert and Danger response, relay contacts and return to the normal state.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.