Match the complete marking
Include 3300/48-03-02-02-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 3300/48-03-02-02-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 3300/48-03-02-02-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300/48-03-02-02-00
-
Weight:1.08 kg
-
Tariff Code:8537101190
-
Monitor function:Two-channel casing expansion
-
Full-scale range:0–2 in.
-
Transducer input:2 in. DC LVDT; 10 mV/mil
-
Alarm relay option:Hermetically sealed
-
Agency approval option:00 — Not required
-
Signal input impedance:1.0 megohm
-
Nominal power consumption:1.5 W
-
Signal-conditioning accuracy:±0.33% FS typical; ±1% FS maximum at +25°C
-
Recorder formats:4–20 mA; 1–5 Vdc; 0 to -10 Vdc
-
Alarm measurement:Differential mode only
-
Operating temperature:0 to +65°C
-
Relative humidity:Up to 95%, noncondensing
Information
- Bently Nevada 3300/48-03-02-02-00 serves existing 3300 rack installations. Hermetically sealed relay contacts connect differential casing-expansion alarm decisions to the configured rack alarm circuits.
Transducer match: 2 in. DC LVDT; 10 mV/mil
Relay configuration: Hermetically sealed
Alarm basis: Differential casing movement
Alert and Danger levels are adjustable over 0–100% of full-scale in Differential mode. Display and setting resolution is within ±1.6% of full-scale; alarm repeatability after adjustment is within ±0.4% of full-scale. Hermetically sealed is the ordered relay configuration. Delay, reset and energized-state settings remain separate commissioning choices that must match the rack alarm arrangement.
Recorder outputs can be configured for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc, with two direct channels or one differential measurement. A current output supports 0–600 ohms; a voltage output requires at least 10 kilohms. Buffered transducer connections support signal inspection, while the LCD and OK indicators provide adjustment and diagnostic information.
-
Bently Nevada 3300/48-03-02-02-00 technical reference
Original manufacturer excerpt - PDF, 4 pages. Monitor option identification, reading setpoints, self-tests and diagnostic indications. -
Bently Nevada 3300/48-03-02-02-00 installation guide
Prepared by Apter Power - PDF, 5 pages. Configuration review, signal connections, alarm settings, commissioning and handover.
Integration boundary: Coordinate the machine mounting arrangement, recorder scaling and rack alarm logic. A matching family name alone does not establish an interchangeable range, input sensitivity or relay module.
-
Casing growth
Track movement of the casing relative to the machine foundation using two DC LVDTs. -
Unequal movement
Use the differential measurement to compare displacement at the two monitored locations. -
Rack alarm circuits
Integrate the hermetically sealed relay option with the intended Alert and Danger circuits. -
Trend recording
Scale the selected current or voltage recorder signal to the 0–2 in. monitor range.
Use 2 in. dc lvdt; 10 mv/mil inputs with the 0–2 in. scale.
Alert and Danger comparisons are available only in Differential mode.
The order specifies hermetically sealed; verify the actual rear module and downstream contact circuit.
Use 0–600 ohms for 4–20 mA or at least 10 kilohms for a voltage output.
Record delay, reset, energized state, recorder mode and upscale direction before replacement.
Resolve active error indications and verify both channels before returning the measurement to service.
Alternative Names
Technical notes
Measurement relationship: The LVDTs measure casing displacement relative to the foundation. This is not a rotor differential-expansion probe measurement.
Alarm configuration: Hermetically sealed is the ordered relay option. Alert and Danger comparisons operate only in Differential mode; verify relay wiring, reset behavior and delay before service.
Technical reference: Bently Nevada 3300/48 Specifications and Ordering Information, 141510-01 Rev. F; Case Expansion Monitor Operation, 84417-01 Rev. NC. The original operation excerpt covers option identification, setpoint reading and self-test indications.
FAQ View All FAQ
-
Which relay configuration is encoded by 3300/48-03-02-02-00?The third option 02 specifies hermetically sealed alarm relays. Confirm the rear relay module and its contact connections against the installed alarm circuit; sealing type does not establish a hazardous-area approval.
-
What expansion span is displayed by 3300/48-03-02-02-00?The 03 range option selects 0–2 in. The 02 input option matches a 2 in. DC LVDT at 10 mV/mil, so the input sensitivity and inch scale must be retained together.
-
What can be checked at the buffered outputs of 3300/48-03-02-02-00?Each transducer has a buffered coaxial output at the front and a corresponding rear terminal connection. The outputs are short-circuit protected and have a specified 100-ohm output impedance.
-
Can 3300/48-03-02-02-00 alarms be latched separately?Alert and Danger reset modes are independently selectable for latching or nonlatching operation. Verify the installed reset configuration and the system reset function when commissioning the relay outputs.
-
How does 3300/48-03-02-02-00 indicate the first alarm event?First Out can be enabled or disabled. A flashing alarm LED indicates First Out, with independent indication for Alert and Danger; this differs from the green OK diagnostic flashing patterns.
-
How are the relay energized states selected on 3300/48-03-02-02-00?Alert and Danger relay modes can each be configured as normally energized or normally de-energized. Verify actual contact behavior and the downstream circuit response under the approved commissioning procedure.
-
What does a 63-segment display mean for 3300/48-03-02-02-00 readings?Each channel uses a 63-segment vertical LCD bargraph, with display resolution within ±1.6% of monitor full-scale. The LCD also indicates error codes and adjustment mode.
-
Does 3300/48-03-02-02-00 include an agency approval option?The final 00 means no agency approval is requested. Do not interpret the hermetically sealed relay option as an approval for a hazardous location; use the complete installed-system certification requirements.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.