-
Match the complete marking
Include 3300/48-01-01-00-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 3300/48-01-01-00-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 3300/48-01-01-00-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300/48-01-01-00-00
-
Weight:1.08 kg
-
Tariff Code:8537101190
-
Monitor function:Two-channel casing expansion
-
Full-scale range:0–1 in.
-
Transducer input:1 in. DC LVDT; 9 mV/mil
-
Alarm relay option:No relays
-
Agency approval option:00 — Not required
-
Signal input impedance:1.0 megohm
-
Nominal power consumption:1.5 W
-
Signal-conditioning accuracy:±0.33% FS typical; ±1% FS maximum at +25°C
-
Recorder formats:4–20 mA; 1–5 Vdc; 0 to -10 Vdc
-
Alarm measurement:Differential mode only
-
Operating temperature:0 to +65°C
-
Relative humidity:Up to 95%, noncondensing
Information
- Bently Nevada 3300/48-01-01-00-00 serves existing 3300 rack installations. A single-inch casing-growth channel requires the display range and DC LVDT sensitivity to remain matched throughout the signal path.
Transducer match: 1 in. DC LVDT; 9 mV/mil
Relay configuration: No relays
Alarm basis: Differential casing movement
Alert and Danger levels are adjustable over 0–100% of full-scale in Differential mode. Display and setting resolution is within ±1.6% of full-scale; alarm repeatability after adjustment is within ±0.4% of full-scale. No relays is the ordered relay configuration. Delay, reset and energized-state settings remain separate commissioning choices that must match the rack alarm arrangement.
Recorder outputs can be configured for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc, with two direct channels or one differential measurement. A current output supports 0–600 ohms; a voltage output requires at least 10 kilohms. Buffered transducer connections support signal inspection, while the LCD and OK indicators provide adjustment and diagnostic information.
-
Bently Nevada 3300/48-01-01-00-00 technical reference
Original manufacturer excerpt - PDF, 4 pages. Monitor option identification, reading setpoints, self-tests and diagnostic indications. -
Bently Nevada 3300/48-01-01-00-00 installation guide
Prepared by Apter Power - PDF, 5 pages. Configuration review, signal connections, alarm settings, commissioning and handover.
Integration boundary: Coordinate the machine mounting arrangement, recorder scaling and rack alarm logic. A matching family name alone does not establish an interchangeable range, input sensitivity or relay module.
-
Casing growth
Track movement of the casing relative to the machine foundation using two DC LVDTs. -
Unequal movement
Use the differential measurement to compare displacement at the two monitored locations. -
Rack alarm circuits
Provide the required system relay arrangement for this no-relay option. -
Trend recording
Scale the selected current or voltage recorder signal to the 0–1 in. monitor range.
Use 1 in. dc lvdt; 9 mv/mil inputs with the 0–1 in. scale.
Alert and Danger comparisons are available only in Differential mode.
The order specifies no relays; verify the actual rear module and downstream contact circuit.
Use 0–600 ohms for 4–20 mA or at least 10 kilohms for a voltage output.
Record delay, reset, energized state, recorder mode and upscale direction before replacement.
Resolve active error indications and verify both channels before returning the measurement to service.
Alternative Names
Technical notes
Measurement relationship: The LVDTs measure casing displacement relative to the foundation. This is not a rotor differential-expansion probe measurement.
Alarm configuration: No relays is the ordered relay option. Alert and Danger comparisons operate only in Differential mode; verify relay wiring, reset behavior and delay before service.
Technical reference: Bently Nevada 3300/48 Specifications and Ordering Information, 141510-01 Rev. F; Case Expansion Monitor Operation, 84417-01 Rev. NC. The original operation excerpt covers option identification, setpoint reading and self-test indications.
FAQ View All FAQ
-
Which LVDT range matches 3300/48-01-01-00-00?The 01 full-scale option selects 0–1 in., and input option 01 selects a 1 in. DC LVDT with a 9 mV/mil scale factor. Match both channels to this configuration; a 2 in. LVDT requires a different input setting.
-
What does 3300/48-01-01-00-00 measure relative to the machine foundation?Two DC LVDTs measure casing movement relative to the foundation. Direct mode displays each channel separately; differential mode displays the difference between their measurements.
-
Can 3300/48-01-01-00-00 generate Alert and Danger alarms in Direct mode?No. Alert and Danger setpoints apply only to the differential measurement. Direct readings are available for the individual casing-expansion channels.
-
How does the no-relay option affect 3300/48-01-01-00-00 integration?The third 00 option specifies no local alarm relays. The rack alarm architecture must provide the appropriate relay arrangement; the no-relay monitor does not supply local relay contacts by itself.
-
Which recorder signals can be selected on 3300/48-01-01-00-00?The recorder circuit can be configured for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc. Its measurement mode can be two direct channels or one differential channel, proportional to the selected full-scale range.
-
What load can the 4–20 mA output of 3300/48-01-01-00-00 drive?The specified current-output load range is 0–600 ohms, with 0 to +12 Vdc compliance across the load. Voltage-output configurations instead require at least 10 kilohms.
-
How should a flashing green OK indicator on 3300/48-01-01-00-00 be interpreted?A 1 Hz flash indicates a transducer that was previously not OK but has recovered. A 5 Hz flash indicates stored error codes. Diagnose the corresponding status before clearing the indication.
-
Where can 3300/48-01-01-00-00 be installed in a 3300 rack?It occupies one monitor position. Positions 1 and 2 are reserved for the power supply and system monitor, respectively; confirm the signal-input and relay arrangement at the selected monitor position.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.


