Speak to a sourcing specialist
sales13@apterpower.com

3300/15 02-02-01-00-00-00

Dual Radial Vibration Monitor
In Stock
Ships by Saturday, November 7
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Bently Nevada 3300/15 02-02-01-00-00-00 is a 0–5 mils pp 3300/15 Dual Radial Vibration Monitor configured for a 3000 Proximitor, 200 mV/mil input and epoxy-sealed relay selection. The 3000 Proximitor circuit requires the rack transducer supply to be set for -18 V operation.
Get a quick price for 3300/15 02-02-01-00-00-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 3300/15 02-02-01-00-00-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300/15 02-02-01-00-00-00
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Measurement function:
    dual-channel radial vibration
  • Selected range:
    0–5 mils pp
  • Input system:
    3000 Proximitor, 200 mV/mil
  • Signal sensitivity:
    200 mV/mil where specified by the selected input
  • Alarm relay option:
    Epoxy-sealed
  • Range multiplier:
    None
  • Channel test method:
    Controlled input change, one channel at a time
  • Configuration identity:
    Complete order code required

Information

Overview Manuals Common Applications Product Precautions
Bently Nevada 3300/15 02-02-01-00-00-00 conditions two radial-vibration signals for continuous shaft-motion indication while retaining the selected 3000 Proximitor power and scaling requirements.
  • Uses the selected 0–5 mils pp measurement range.
  • Accepts 3000 Proximitor, 200 mV/mil.
  • Uses epoxy-sealed alarm relay hardware.
  • Uses the base range without a multiplication option.

The complete channel must preserve the transducer source, displayed range, relay interface and barrier selection together. A monitor from the same family can produce a plausible indication while applying a different scale or output arrangement.

Important Notice: Match the complete 3300/15 02-02-01-00-00-00 order code, input source and rear connection assembly before installation; then verify each channel through a controlled response test.

Bently Nevada 3300/15 02-02-01-00-00-00 Manuals & Downloads
Bently Nevada 3300/15 02-02-01-00-00-00 Technical Reference (PDF)Bently Nevada 3300/15 02-02-01-00-00-00 Installation & Commissioning Guide (PDF)

The technical reference, installation guide and complete product information PDF are separate documents with different scopes. All three apply only to the exact model shown.

Radial Shaft Vibration On Fluid-Film Bearing Machinery
Apply the selected 0–5 mils pp span to the intended machine measurement.
Two-channel condition monitoring
Keep channel identity from the field transducer through indication and alarms.
Controlled maintenance testing
Inject or apply a known change and compare each response stage.
Protection-system integration
Verify the selected relay and barrier interface with the receiving circuit.
Apply these checks to the exact Bently Nevada 3300/15 02-02-01-00-00-00 configuration before isolation, replacement or return to service.
1
Confirm the full 3300/15 02-02-01-00-00-00 marking before removing the installed monitor.
2
Record both channel readings and the selected 0–5 mils pp scale before isolation.
3
Preserve the 3000 Proximitor, 200 mV/mil transducer and sensitivity selection.
4
Retain the epoxy-sealed relay arrangement and its contact logic.
5
Do not introduce a safety barrier without reviewing the complete input loop.
6
Do not infer an agency approval from another order-code variant.
7
Verify the base range is used without multiplication.
8
Test each channel, alarm state and downstream response before returning protection to service.

Technical notes

Use a controlled input condition to verify the 0–5 mils pp scale, 3000 Proximitor, 200 mV/mil conversion, channel identity and selected output behavior. Restore the recorded alarm, delay, reset, multiplier and bypass states only after the complete path responds correctly.

FAQ View All FAQ

  • What does the selected 0–5 mils pp span control in 3300/15 02-02-01-00-00-00?
    The selected measurement span is 0–5 mils pp. Alarm and recorder scaling must be checked against that span rather than copied from a different range option.
  • What input-chain details must be retained for 3300/15 02-02-01-00-00-00?
    This configuration uses 3000 Proximitor, 200 mV/mil. Preserve the transducer family, sensitivity and signal polarity as one measurement chain.
  • Which test separates 3300/15 02-02-01-00-00-00 measurement scaling from relay operation?
    The selected alarm output uses epoxy-sealed relay hardware. Contact logic, energization and downstream wiring still require a functional test.
  • How should field wiring be traced for the standard input interface of 3300/15 02-02-01-00-00-00?
    No safety-barrier option is selected. Do not move field conductors from a barrier-equipped circuit without an engineering review.
  • Should 3300/15 02-02-01-00-00-00 be treated as an agency-approved order-code variant?
    No agency-approval option is selected in this order code. Do not infer an approval from another unit in the same monitor family.
  • Can a multiplied setpoint be transferred directly to 3300/15 02-02-01-00-00-00?
    No range multiplier is selected, so the stated scale is the active base range. A multiplied setting from another monitor must not be transferred.
  • What sequence verifies the indication and output path of 3300/15 02-02-01-00-00-00?
    Apply a controlled input change to one identified channel at a time, then compare the local indication, buffered or recorder signal, alarm state and return to normal.
  • What information prevents a wrong-variant replacement of 3300/15 02-02-01-00-00-00?
    Record the complete model, 0–5 mils pp scale, 3000 Proximitor, 200 mV/mil input, relay and barrier choices, channel assignments, setpoints, delays and the observed acceptance results.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.