Match the complete marking
Match IRDH275-435, revision and visible labels.
-
Check the offered item before ordering
Confirm Bender IRDH275 unearthed AC and DC power systems, companion hardware and wiring.
Technical specifications for IRDH275-435
-
Manufacturer:BENDER
-
Spare Part Number:IRDH275-435
-
Weight:0.55 kg
-
Tariff Code:8537101190
-
Nominal system voltage, AC:0 to 793 V
-
Nominal system voltage, DC:0 to 650 V
-
Supply voltage, AC:88 to 264 V
-
Supply voltage, DC:77 to 286 V
-
Power consumption:14 VA maximum
-
Response-value range:1 kohm to 10 Mohm
-
Measuring voltage:50 V maximum
-
Measuring current:280 uA maximum
-
System leakage capacitance:500 uF maximum
-
Alarm relays:2 changeover contacts
-
Interface:RS-485
-
Device protection:IP30
-
Terminal protection:IP20
-
Operating temperature:-10 to +55 deg C
Information
- IRDH275-435 continuously measures insulation resistance in an unearthed network and reports two configurable alarm stages locally, by relay and over RS-485.
Wide coupling range: AC, DC and mixed systems are monitored within the documented nominal-voltage limits.
Two-stage alarm handling: Independently configured response values drive two relay outputs and the serial interface.
The device uses an active measuring signal and evaluates the complete network including leakage capacitance. Alarm thresholds, time delay, relay operating mode and RS-485 settings must be copied from the installed configuration.
After replacement, run the built-in test, verify the measuring circuit and protective conductor, simulate an approved insulation fault and confirm both local indication and remote alarm transmission.
IRDH275-435 Technical Data Reference
Bender IRDH275 operating manual D00122; selected exact-model and documented family data for IRDH275-435.IRDH275-435 Installation & Verification Guide
Model-specific installation, wiring, inspection and commissioning checks for IRDH275-435.
Application scope: Alarm-integration boundary: Response values, delay, relay mode, memory behavior and RS-485 settings must reproduce the approved electrical-protection design.
Unearthed industrial networks
Detect developing earth faults without immediate process shutdown.Converter-fed systems
Supervise mixed AC/DC networks within the documented coupling boundary.Critical-power systems
Provide staged insulation alarms where continuity of supply is required.Predictive electrical maintenance
Trend insulation resistance and leakage-capacitance behavior.
Record voltage, frequency, DC components and converter topology.
Label measuring, earth, supply and relay terminals.
Capture alarm values, delays, relay modes and address.
Avoid parallel active insulation monitors unless explicitly approved.
Verify display, relay outputs and communication.
Confirm response value and alarm routing before handover.
Alternative Names
Technical notes
Connected-network boundary: Identify every galvanically connected feeder, converter, filter and DC link included in the insulation measurement.
Measuring-circuit integrity: Verify the network coupling and protective-earth connection before running internal or external fault tests.
Two-stage alarm proof: Simulate an approved insulation fault and confirm display, both relays and serial alarm transmission.
FAQ View All FAQ
-
Which system-voltage limits apply to IRDH275-435?Use it only within the documented 0-793 V AC or 0-650 V DC nominal system limits and the approved coupling arrangement.
-
Why must parallel insulation monitors be considered before fitting IRDH275-435?Two active measuring devices on the same connected network can influence each other and invalidate the insulation reading.
-
How does system leakage capacitance affect IRDH275-435?Higher capacitance can extend measuring and response time; the documented upper boundary is 500 uF.
-
Which alarm settings should be retained for IRDH275-435?Record both response values, time delay, relay energization mode, fault memory and any start-up behavior.
-
What should the RS-485 check for IRDH275-435 include?Verify address, protocol mode, termination, polarity and receipt of the correct measured value and alarm states.
-
How is the measuring connection of IRDH275-435 proven?Inspect the network coupling and protective-earth path, then run the internal test and an approved external fault simulation.
-
What network changes require reassessment of IRDH275-435?Adding converters, filters, DC links, large cable capacitance or galvanically connected sections can change the measuring boundary.
-
Which alarm and insulation checks complete commissioning of IRDH275-435?Retain the saved configuration, internal-test result, approved simulated-fault response, relay operation and remote-system confirmation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.