Product Describe:

ABB CI867K01 3BSE043660R1 combines a CI867 Modbus TCP communication interface with its TP867 baseplate for AC 800M systems. The two Ethernet channels connect the controller to external Modbus TCP devices through the CEX-Bus architecture.
Get a quick price for CI867K01 3BSE043660R1
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for CI867K01 3BSE043660R1

  • Manufacturer:
    ABB
  • Product Category:
    DCS Systems
  • Spare Part Number:
    CI867K01 3BSE043660R1
  • Estimated shipping dimensions:
    18.5×6.5×12.6cm
  • Weight:
    0.5 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Sweden
  • Product family:
    AC 800M communication interfaces
  • Package designation:
    CI867K01
  • ABB article number:
    3BSE043660R1
  • Package contents:
    CI867 communication interface and TP867 baseplate
  • Interface channels:
    2
  • Protocol:
    Modbus TCP
  • Channel 1:
    10/100Base-TX over RJ45
  • Channel 2:
    10Base-T over RJ45
  • Controller connection:
    CEX-Bus
  • Current consumption:
    160 mA typical; 250 mA maximum from CEX-Bus 24 V DC
  • Power dissipation:
    3.8 W typical
  • Protection rating:
    IP20
  • Redundant configuration:
    Supported
  • Hot swap:
    Supported
  • Recommended process cable:
    Category 5 shielded twisted-pair cable or better
  • Published cable distance:
    30 m maximum from CI867 to the next Ethernet device

Information

Overview Manuals Common Applications Product Precautions
Within an AC 800M station, ABB CI867K01 3BSE043660R1 adds a dedicated CEX-Bus communication path for exchanging Modbus TCP data with approved Ethernet equipment.
  • Two Ethernet channels on the CI867 interface
  • Channel 1 supports 10/100Base-TX operation
  • Channel 2 supports 10Base-T operation
  • Redundant configuration and hot-swap support

The package combines the CI867 communication unit with the keyed TP867 baseplate and its two RJ45 connections. Power is supplied from the controller through the CEX-Bus, while status and traffic indicators support commissioning and diagnostics. Before exchange, record both channel assignments, switch connections, IP settings, redundancy role and the controller hardware configuration; after installation, verify Modbus TCP traffic and every affected data path.

Important Notice: Confirm the complete CI867K01 3BSE043660R1 identity, TP867 baseplate, controller version and recorded network configuration before replacement or commissioning.

ABB CI867K01 3BSE043660R1 Manuals & Downloads
ABB CI867K01 3BSE043660R1 Official Manufacturer Reference Excerpt (PDF)ABB CI867K01 3BSE043660R1 Installation & Commissioning Guide (PDF)

The first document contains the applicable official manufacturer reference pages; the second organizes a separate installation, configuration, testing and handover workflow.

Modbus TCP device integration
Connects an AC 800M controller with approved Ethernet devices that exchange Modbus TCP data.
Dual-channel network architecture
Provides separate documented Channel 1 and Channel 2 Ethernet connections through the TP867 baseplate.
Redundant controller communications
Supports an engineered redundant CI867 arrangement after roles and configuration are restored.
Installed-base interface replacement
Reinstates the recorded CEX-Bus module position and network assignments during controlled maintenance.
Read the applicable ABB instructions before work. Verify CI867K01 3BSE043660R1 and the installed system configuration before isolation or replacement.
1
Record the complete ABB CI867K01 3BSE043660R1 identity and CEX-Bus position.
2
Place the controller, process and connected Ethernet equipment in the approved maintenance state.
3
Back up the AC 800M hardware configuration, IP settings and Modbus TCP assignments.
4
Label both RJ45 links and record their switch ports, channel roles and redundancy state.
5
Verify that the keyed TP867 baseplate and CI867 interface match the documented installation.
6
Inspect CEX-Bus contacts, cable shielding and connector latches before seating the package.
7
Review status, traffic and redundancy indicators after the controller recognizes the interface.
8
Prove every configured Modbus TCP exchange and record the acceptance results before release.

Technical notes

Retain the validated AC 800M hardware tree, CEX-Bus position and both Ethernet-channel records. Acceptance must confirm normal indicators, channel links, redundancy state and each configured Modbus TCP exchange.

FAQ View All FAQ

  • What does ABB CI867K01 3BSE043660R1 contain?
    ABB CI867K01 3BSE043660R1 contains the two-channel CI867 Modbus TCP communication interface and the TP867 baseplate.
  • How does CI867K01 3BSE043660R1 connect to the AC 800M controller?
    The CI867 interface receives power and controller communication through the AC 800M CEX-Bus.
  • Which Ethernet speeds are available on ABB CI867K01 3BSE043660R1?
    Channel 1 supports 10 or 100 Mbit/s operation, while Channel 2 supports 10 Mbit/s operation.
  • Can ABB CI867K01 3BSE043660R1 operate in a redundant configuration?
    ABB documents redundant configuration support for the CI867 interface when the approved controller architecture is used.
  • Does CI867K01 3BSE043660R1 support hot swapping?
    The published CI867 technical specification identifies hot swapping as supported.
  • Which current and power values apply to ABB CI867K01 3BSE043660R1?
    The interface typically consumes 160 mA from the 24 V CEX-Bus supply, with a stated maximum of 250 mA and typical dissipation of 3.8 W.
  • What cable condition should be checked for CI867K01 3BSE043660R1?
    Technicians should verify Category 5 shielded twisted-pair cabling or better and keep the documented link to the next Ethernet device within 30 m.
  • Which tests complete commissioning of ABB CI867K01 3BSE043660R1?
    Commissioning is complete after both channel links, status indicators, redundancy role and every configured Modbus TCP data exchange pass the approved checks.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.