ABB SCC-F 23212-0-110310 is a sample-gas feed unit for continuous, dosed sample delivery. ABB documents two independent gas paths, corrosion-resistant metal-free gas lines and operation with the SCC-C sample-gas cooler.
ABB SCC-F 23212-0-110310 is a sample-gas feed unit for continuous, dosed sample delivery. ABB documents two independent gas paths, corrosion-resistant metal-free gas lines and operation with the SCC-C sample-gas cooler.
Dual gas paths: Feeds two independent sample-gas streams through separate conditioning paths.
Dosed sample delivery: Uses the documented rotameter and needle-valve arrangement for controlled flow.
Corrosion-resistant path: Keeps the sample path metal-free for the documented gas-conditioning duty.
Cooler integration: Works with the SCC-C cooler when the inlet dew-point condition requires conditioning.
Use SCC-F only within the documented sample-gas limits. It is not approved for ignitable gas-air or gas-oxygen mixtures, flammable sample gas or hazardous-area installation.
Important Notice: Confirm the complete ABB SCC-F 23212-0-110310 identity and controlled configuration before commissioning.
The first document presents model-specific technical and system data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Continuous gas analysis
Feeds a controlled sample stream to an approved analyzer system.
Dual-stream conditioning
Maintains two independent sample-gas paths.
SCC-C integration
Operates with the ABB sample-gas cooler where dew-point control is required.
Flow-supervised sampling
Uses the documented flow and status-switch arrangement for monitored delivery.
Read the applicable ABB instructions before work. Verify ABB SCC-F 23212-0-110310 and the installed system configuration before commissioning.
1
Verify ABB SCC-F 23212-0-110310 before installation.
2
Confirm sample-gas pressure and inlet temperature are within ABB limits.
3
Maintain the required inlet dew-point margin or use approved conditioning.
4
Do not use SCC-F with ignitable gas-air or gas-oxygen mixtures.
5
Do not use SCC-F for flammable sample gas or in hazardous areas.
6
Set each gas path within the documented flow range.
7
Complete the required warm-up before evaluating sample stability.
8
Verify flow, tightness and status-switch operation before release.
Technical notes
Use SCC-F only within the documented sample-gas limits. It is not approved for ignitable gas-air or gas-oxygen mixtures, flammable sample gas or hazardous-area installation.