Product Describe:

ABB DSDX452L 5716075-U is listed here as an S400 low-signal digital basic I/O unit. The DSDX 452L technical configuration has twenty 24 V DC digital inputs and twelve low-level relay outputs.
  • Manufacturer part number
    DSDX452L 5716075-U
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    22.9cm x 10.2cm x 25.4cm
  • Country of Origin
    USA
Get a quick price for DSDX452L 5716075-U
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full DSDX452L 5716075-U identification and photographs of the connector bank, address setting and expansion connection.

  • 1

    Confirm the offer

    Check the low-level relay-output role, SDB connection and expansion pairing against the installed station before approving the offered item.

  • 2

    Arrange dispatch

    Confirm quantity, destination and agreed dispatch date in the quotation.

  • Match the complete marking

    Send photographs of the complete DSDX452L 5716075-U marking, station address switches, field connectors and any connected expansion unit.

  • Check the offered item before ordering

    Compare the offered basic-unit label and low-level output configuration with the installed S400 station. Confirm the required expansion-unit pairing and included hardware in the quotation.

Technical specifications for DSDX452L 5716075-U

  • Manufacturer:
    ABB
  • Product Category:
    DCS Systems
  • Spare Part Number:
    5716075-U
  • Weight:
    2.85 kg
  • Tariff Code:
    8537101190
  • S400 unit class:
    Digital basic unit, low signal level outputs
  • Digital inputs:
    20
  • Input signal:
    24 V DC digital
  • Digital outputs:
    12
  • Output type:
    Relay, low-level signal type
  • Station communication:
    MasterFieldbus SDB
  • Monitoring:
    Power loss; startup self-test; communication
  • Expansion: digital I/O:
    DSDX 451 or DSDX 451L
  • Expansion: digital input:
    DSDI 451
  • Field connection:
    Two-wire connectors; no extra terminal unit
  • Address access:
    Switches beneath removable top lid
  • Housing:
    Cast aluminium chassis with plastic cover

Information

Overview Downloads Applications / Compatibility Product Precautions
  • ABB DSDX452L 5716075-U serves an Advant Master S400 remote I/O station where digital sensing and low-level relay switching share one basic-unit position. The station communicates with its process station on MasterFieldbus SDB.
Input bank: Twenty 24 V DC digital inputs in the DSDX 452L basic unit.
Output bank: Twelve low-level signal relay outputs.
Expansion path: DSDX 451, DSDX 451L or DSDI 451 can extend the basic unit.
The DSDX 452L basic unit collects twenty digital inputs and drives twelve low-level relay outputs. The low-signal designation matters when matching the existing output loads; a standard relay-output variant should not be assumed to have the same circuit role.

MasterFieldbus SDB connects the S400 basic unit with its process station. ABB specifies power-loss, startup self-test and communication monitoring for this unit. Record the existing station address, bus connection and diagnostic indication before replacing hardware.

ABB lists DSDX 451, DSDX 451L and DSDI 451 as expansion options for DSDX 452L. Match the connected expansion unit, field connectors and grouped I/O assignment. An S800 migration can reuse selected S400 wiring through a separately designed TU40x termination arrangement; it is not a direct basic-unit substitution.
Controller platform reference: ABB Advant Master S400 Remote I/O. Confirm the installed SDB station, expansion pairing and low-level output loads.
The technical reference summarizes the DSDX 452L signal, bus and expansion functions. The separate field guide covers connector records, address checks and return-to-service testing.
The technical reference and field guide are separate Apter Power resources. Check the installed network design and applicable manufacturer instructions before a change.
System and supply context: The DSDX 452L is a basic unit in ABB Advant Master S400 Remote I/O. Its outputs are the low-level signal relay version, and the complete installed station may include a separate expansion unit.

Application scope: Use it where the approved S400 design calls for the same 24 V input bank, low-level output circuits and MasterFieldbus SDB connection. Check wiring and controller configuration before considering a different S400 unit or an S800 migration.
Prepare ABB DSDX452L 5716075-U for its configured installation using these checks.
Confirm the low-signal version

Check that the installed output loads use the DSDX 452L low-level relay configuration.

Record station address

Capture switch positions and the assigned SDB station before removing the unit.

Map each I/O group

Label twenty inputs, twelve output circuits and the expansion connection separately.

Control the bus state

Put the affected process I/O in the approved maintenance condition before disconnecting SDB.

Check connector identity

Preserve the two-wire field connector grouping and chassis orientation.

Prove operation after return

Review power-loss, self-test and communication diagnostics, then exercise affected I/O points.

Alternative Names

ABB DSDX 452L S400 Low-Signal Basic Unit ABB Advant Master DSDX452L Digital I/O Unit

Technical notes

Output compatibility: DSDX 452L is the low-level signal relay version; match the connected output circuits.

Expansion boundary: ABB lists DSDX 451, DSDX 451L and DSDI 451 for this basic unit.

Bus monitoring: The basic unit monitors power loss, startup self-test and SDB communication.

FAQ View All FAQ

  • Why does the low-level output designation matter on DSDX452L 5716075-U?
    It identifies the DSDX 452L relay-output variant. Compare the existing twelve output circuits and loads before replacing it with a standard DSDX 452 or another S400 unit.
  • Which expansion units can extend DSDX452L 5716075-U?
    ABB lists DSDX 451, DSDX 451L and DSDI 451. Confirm which unit is actually installed and preserve its channel assignments.
  • How should an SDB communication fault be isolated on DSDX452L 5716075-U?
    Check the station address, MasterFieldbus SDB connection and process-station diagnostics alongside the unit’s communication indication; do not treat it as an output-channel fault alone.
  • What does a startup self-test result tell the team about DSDX452L 5716075-U?
    It is one of the unit’s monitored conditions. A successful self-test does not replace checks of field wiring, output loads and SDB communication after installation.
  • Why should the address switches be recorded before changing DSDX452L 5716075-U?
    The switches sit under the accessible lid and determine station identity. Restore the approved address so the process station reaches the intended I/O position.
  • How should the two-wire field connectors be handled on DSDX452L 5716075-U?
    Label each connector and preserve channel grouping. ABB says S400 I/O uses two-wire connectors without an additional terminal unit.
  • Can DSDX452L 5716075-U be directly replaced by an S800 module?
    No direct substitution is established. ABB describes TU40x termination arrangements for staged S400-to-S800 migration; the specific wiring and I/O design must be engineered.
  • Which functional checks should close a DSDX452L 5716075-U replacement?
    Verify station communication and diagnostics, then test the affected 24 V input states and low-level relay output circuits against the approved process response.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.