Speak to a sourcing specialist
sales13@apterpower.com
Get a quick price for 39VIMNBN
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 39VIMNBN

  • Manufacturer:
    Siemens
  • Product Category:
    DCS Systems
  • Spare Part Number:
    39VIMNBN
  • Estimated shipping dimensions:
    4x26x30.7cm
  • Weight:
    1.92 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • System family:
    APACS+
  • Signal direction:
    Field to controller
  • Input class:
    Voltage input
  • Associated assembly:
    16171-21/03
  • Mounting context:
    Existing system position
  • Connection control:
    Match installed terminals
  • Configuration basis:
    Preserve assigned settings
  • Acceptance focus:
    Confirm end-to-end response

Information

Overview Manuals Common Applications Product Precautions
Siemens 39VIMNBN performs the process voltage input module function within the APACS+ platform while retaining the interfaces assigned to its installed position.
  • Provides the process voltage input module function.
  • Integrates with the APACS+ platform.
  • Retains the assigned signal or communication path.
  • Uses the complete 39VIMNBN identity for replacement control.

The process voltage input module should remain matched to its installed terminals, configuration and receiving system. Verify the complete path after replacement.

Important Notice: Match Siemens 39VIMNBN to the installed position, terminals and controlled configuration. Verify the complete signal or communication path before release.

Siemens 39VIMNBN Manuals & Downloads
Siemens 39VIMNBN Technical Reference (PDF)Siemens 39VIMNBN Installation & Commissioning Guide (PDF)

The first PDF covers the product function and technical data. The second covers connection checks, commissioning and release steps.

Installed-base maintenance
Restore the assigned process voltage input module position without changing the surrounding system design.
Loop and channel service
Retain terminal assignments, scaling and channel ownership during controlled replacement.
Fault isolation
Separate module, field wiring and configuration causes during troubleshooting.
Commissioning
Prove the complete signal path before returning the process to service.
Apply these checks to the exact Siemens 39VIMNBN position before isolation, replacement or release.
1
Confirm the complete Siemens 39VIMNBN marking before removal.
2
Place the affected APACS+ function in its approved maintenance state.
3
Record terminals, connectors and installed orientation before disconnection.
4
Retain channel assignments, scaling and communication settings.
5
Inspect mating contacts and terminal hardware for damage or contamination.
6
Restore shields, commons and protective grounding exactly as assigned.
7
Energize under controlled conditions and review module status.
8
Verify the end-to-end process response before release.

Technical notes

Match Siemens 39VIMNBN to the installed position, terminals and controlled configuration. Verify the complete signal or communication path before release.

FAQ View All FAQ

  • Which control family uses Siemens 39VIMNBN?
    Siemens 39VIMNBN belongs to the APACS+ platform.
  • What function does Siemens 39VIMNBN perform?
    It performs the process voltage input module function.
  • Which input class applies to Siemens 39VIMNBN?
    Input class: Voltage input.
  • How does Siemens 39VIMNBN use its associated assembly?
    Associated assembly: 16171-21/03.
  • Why must the mounting context be checked on Siemens 39VIMNBN?
    The applicable value is Existing system position and it must match the installed position.
  • Which connection control should be retained for Siemens 39VIMNBN?
    Retain Match installed terminals.
  • What commissioning result is required for Siemens 39VIMNBN?
    Confirm the complete process voltage input module path from its field interface through the assigned system function.
  • How should Siemens 39VIMNBN be identified before replacement?
    Match the full 39VIMNBN marking and all installed interfaces before removal.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.