Technical specifications for 6SE3122-4DG40

  • Manufacturer:
    Siemens
  • Product Category:
    General Automation
  • Spare Part Number:
    6SE3122-4DG40
  • Estimated shipping dimensions:
    13x34x39.3cm
  • Weight:
    8.54 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Drive model:
    MD1100/3
  • Product family:
    MIDI MASTER
  • Hardware type:
    Inverter
  • Input supply:
    400–500 V three-phase AC
  • Power rating:
    11.0 kW
  • Input frequency:
    47–63 Hz family specification
  • Operating document:
    G85139-E1720-U325-A
  • Manual edition:
    03.95
  • Acceptance:
    Direction, speed command, current and fault-free run

Information

Overview Manuals Common Applications Product Precautions
Siemens 6SE3122-4DG40 controls a three-phase motor from the MD1100/3 position while retaining the machine's approved power wiring, command path and parameter set.
  • 6SE3122-4DG40
  • MD1100/3
  • MIDI MASTER
  • Inverter

Mains isolation, DC-link discharge, motor direction, speed response and running current are checked in sequence before process load is restored.

Important Notice: Save the parameter set and complete the DC-link discharge procedure before touching the drive terminals.

Siemens 6SE3122-4DG40 Manuals & Downloads
Siemens 6SE3122-4DG40 Technical Reference (PDF)Siemens 6SE3122-4DG40 Official Operating Instructions (PDF)

The technical reference summarizes the MD1100/3 operating envelope; the official ten-page excerpt covers safety, installation, operation, faults and specifications.

Legacy motor-drive renewal
Restores an MD1100/3 position while keeping the recorded motor and mains arrangement.
Controlled-speed machinery
Applies the retained acceleration, deceleration and speed-reference configuration.
Panel refurbishment
Supports like-for-like replacement after terminal, control and cooling details are recorded.
Fault-led maintenance
Uses the drive display and specified fault codes to verify recovery before handover.
Complete these MD1100/3 checks before returning 6SE3122-4DG40 to motor-control service.
1
Confirm both 6SE3122-4DG40 and MD1100/3 on the installed drive.
2
Compare the 400–500 V three-phase supply with the drive and motor records.
3
Save all parameter values and photograph power and control terminals before removal.
4
Isolate the mains and wait for the DC-link discharge procedure to complete.
5
Keep motor, control and power conductors separated as specified.
6
Restore protective earth, terminal torque and enclosure ventilation.
7
Perform a low-risk direction and speed-reference check before loading the machine.
8
Record running current and confirm that no drive fault remains active at release.

Technical notes

Match 6SE3122-4DG40 to the complete installed identity and MICRO MASTER / MIDI MASTER position. Preserve every connection and setting; release only after controlled verification of variable-frequency motor control in the specified MIDI MASTER installation.

FAQ View All FAQ

  • Which MIDI MASTER execution is Siemens 6SE3122-4DG40?
    The operating instructions list it as MD1100/3.
  • What motor-power class is specified for Siemens 6SE3122-4DG40?
    The exact order number is listed at 11.0 kW.
  • Which incoming voltage range applies to Siemens 6SE3122-4DG40?
    The MD1100/3 variant is shown for 400–500 V three-phase AC.
  • Why must the parameter set of Siemens 6SE3122-4DG40 be captured?
    The replacement hardware will not reproduce the installed machine behavior unless the approved settings are retained.
  • When may the power terminals of Siemens 6SE3122-4DG40 be touched?
    Only after the mains is isolated and the specified DC-link discharge interval has elapsed.
  • How should power and control cables be routed for Siemens 6SE3122-4DG40?
    The family instructions require control, supply and motor leads to be laid separately.
  • What is the first functional motor check for Siemens 6SE3122-4DG40?
    Verify rotation direction and speed response under a controlled, low-risk command.
  • What completes Siemens 6SE3122-4DG40 MD1100/3 commissioning?
    Stable operation at the expected current with the intended command path and no active fault completes acceptance.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

You May Also Like

Explore related automation components available through Apter Power.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.