Speak to a sourcing specialist
sales13@apterpower.com

AD916AG FBM204

Integrated Terminal
In Stock
Ships by Saturday, November 7
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Foxboro AD916AG FBM204 serves as an integrated analog i/o termination in the Foxboro FBM module-fieldbus path. It interfaces 0-20 mA input and output loops with FBM204 mixed analog I/O path and the installed termination assembly.
Get a quick price for AD916AG FBM204
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for AD916AG FBM204

  • Manufacturer:
    Invensys
  • Product Category:
    DCS Systems
  • Spare Part Number:
    AD916AG FBM204
  • Estimated shipping dimensions:
    10.2×4.5×10.4 cm
  • Weight:
    0.28 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Analog inputs:
    4 isolated 0-20 mA dc channels
  • Analog outputs:
    4 isolated 0-20 mA dc channels
  • Input devices:
    4-20 mA transmitters or self-powered 20 mA sources
  • Output function:
    Each output drives an external current-loop load
  • Fieldbus:
    Redundant 2 Mbps module fieldbus

Information

Overview Manuals Common Applications Product Precautions
Foxboro AD916AG FBM204 provides the integrated field-termination path for the FBM204 mixed analog input/output subsystem used in current-loop measurement and control.
  • Provides four inputs and four outputs for the documented integrated analog i/o termination function.
  • Handles 0-20 mA input and output loops through the specified Foxboro FBM module-fieldbus path.
  • Works with FBM204 mixed analog I/O path and the installed termination assembly.
  • Input and output channels are galvanically isolated for field-loop separation.

The integrated analog i/o termination belongs in the controlled Foxboro FBM module-fieldbus path and works with FBM204 mixed analog I/O path and the installed termination assembly. Its field connection, companion hardware and project configuration must be reviewed together before the channel is returned to service.

Important Notice: Use AD916AG FBM204 only with FBM204 mixed analog I/O path and the installed termination assembly; verify the field interface and controlled configuration before energizing the subsystem.

Foxboro AD916AG FBM204 Manuals & Downloads
Foxboro AD916AG FBM204 Official Technical Reference Excerpt (PDF)Foxboro AD916AG FBM204 Installation & Commissioning Guide (PDF)

The first document covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

Installed-base maintenance
Restores the documented integrated analog i/o termination position without changing the approved system architecture.
Loop or channel service
Supports verification of 0-20 mA input and output loops at the assigned control-system channel.
Planned replacement
Provides an exact-identity replacement path when FBM204 mixed analog I/O path and the installed termination assembly and the field interface have been confirmed.
Commissioning support
Allows the responsible engineer to prove wiring, configuration, status and response for four inputs and four outputs.
Before installing Foxboro AD916AG FBM204, confirm the documented system, interfaces and controlled configuration.
1
Match the complete AD916AG FBM204 marking to the work order and installed position before removal.
2
Confirm FBM204 mixed analog I/O path and the installed termination assembly before making or breaking any field connection.
3
Keep the assigned 0-20 mA input and output loops within the documented subsystem and range.
4
Record terminal designations, polarity, common and shield treatment before disconnecting conductors.
5
Inspect module seating, connector keying, terminal condition and strain relief before power is restored.
6
Restore the controlled channel configuration, range selection and alarm or timeout behavior after installation.
7
Check local indicators and controller diagnostics for internal, communication or channel faults during commissioning.
8
Prove the intended response across four inputs and four outputs and record the acceptance result before release.

Technical notes

Use AD916AG FBM204 only with FBM204 mixed analog I/O path and the installed termination assembly; verify the field interface and controlled configuration before energizing the subsystem.

FAQ View All FAQ

  • How are inputs and outputs divided on Foxboro AD916AG FBM204?
    The mixed analog subsystem provides four isolated 0–20 mA dc inputs and four isolated 0–20 mA dc outputs.
  • Which field devices can feed the input side of Foxboro AD916AG FBM204?
    The inputs accept 4–20 mA transmitters or self-powered sources delivering up to 20 mA.
  • What load does each Foxboro AD916AG FBM204 output drive?
    Each output is designed to drive an external current-loop load within the documented 0–20 mA output function.
  • Are the analog channels on Foxboro AD916AG FBM204 galvanically isolated?
    Yes. The four input and four output channels are galvanically isolated to separate their field loops.
  • How does Foxboro AD916AG FBM204 exchange mixed I/O data with the system?
    Input values, output commands and status travel through the redundant 2 Mbps module fieldbus.
  • Why must input and output terminals be distinguished on Foxboro AD916AG FBM204?
    The module combines measurement and control paths, so placing a transmitter on an output or a driven load on an input would connect the wrong circuit function.
  • What loop test is appropriate for the four outputs of Foxboro AD916AG FBM204?
    Command each output across the required current range and confirm the external load receives the corresponding 0–20 mA signal without affecting the isolated neighboring channels.
  • What acceptance check covers the input half of Foxboro AD916AG FBM204?
    Apply a known current to each configured input, compare the reported value and confirm the transmitter or self-powered source wiring matches that channel.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.