Match the complete marking
Include SPS5785 51198651-100 and every revision or approval marking visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and interface photos. Have your maintenance team compare the offered SPS5785 51198651-100 with the installed equipment and applicable Honeywell documentation.
Technical specifications for SPS5785 51198651-100
-
Manufacturer:Honeywell
-
Product Category:DCS Systems
-
Spare Part Number:SPS5785 51198651-100
-
Weight:5.2 kg
-
Tariff Code:8537101190
-
Rated AC input:100-240 V AC
-
Rated input frequency:47-63 Hz
-
Rated input current:10 A
-
Main DC output voltage:24-26 V DC
-
Main DC output current:20 A
-
Battery-charger output voltage:54 V DC
-
Battery-charger output current:1 A
-
Synchronization output voltage:6 V AC
-
Synchronization output current:35 mA
-
Maximum ambient temperature:55 °C
-
Status indicators:5
-
Power-supply service benchmark:10 years, manufacturer maintenance guidance
Information
- The exact supply part identifies silver version 3; older silver and black supply numbers follow different maintenance priorities.
Redundancy-aware maintenance: Dedicated feeds and the working supply condition govern the service plan.
Contamination-sensitive exchange: Airflow around the remaining supply is protected during replacement work.
The xPM power-maintenance guidance recommends redundancy with each supply fed by its own dedicated source. During a failed-supply change, disturbance and particle contamination around the working supply can jeopardize the remaining powered path.
Plan replacement of supplies nearing the ten-year service benchmark during scheduled downtime where possible. Follow the xPM service procedure, preserve alarm-contact wiring, and control conductive debris and enclosure access throughout the work.
Apter Power SPS5785 51198651-100 Power-System Technical Reference
Power-supply generation and maintenance reference based on Honeywell xPM service guidance.SPS5785 51198651-100 Engineering Field Guide
Read the exact supply number, Review both redundant feeds, Choose the approved outage.
Application scope: The maintenance guidance recommends a dedicated source for each redundant supply.
xPM power-system support
Review the installed Process Manager power system and exact supply part identity.Planned life-cycle maintenance
Schedule supply exchange around the manufacturer service benchmark.Failed-supply intervention
Protect the remaining operating supply from disturbance and particles.Alarm and enclosure restoration
Verify alarm wiring, grounding, covers and doors after authorized service.
Distinguish version 3 from earlier silver and black part identities.
Identify the dedicated source serving each supply.
Use scheduled downtime for planned working-supply replacement where possible.
Avoid introducing particles near the remaining working power supply.
Capture the existing power-alarm wiring before intervention.
Check grounding, covers, doors and conductive-debris control before release.
Alternative Names
Technical notes
Version identification: 51198651-100 is silver version 3. The earlier silver and black supply numbers are separate service identities.
Replacement timing: Plan exchange near the service benchmark during scheduled downtime and use the applicable xPM procedure.
Redundant feeds: The maintenance guidance recommends a dedicated source for each redundant supply.
FAQ View All FAQ
-
Which silver supply generation corresponds to SPS5785 51198651-100?Honeywell identifies part 51198651-100 as silver version 3. Compare the complete supply part number with the installed maintenance record.
-
How do older silver supply numbers differ from SPS5785 51198651-100?51109684-100/300 identifies version 1 and 51198947-100 identifies version 2. The maintenance guidance recommends priority replacement of those earlier generations.
-
What redundant-feed arrangement should be reviewed for SPS5785 51198651-100?The manufacturer recommends a dedicated source for each supply. Confirm the actual feed arrangement and isolation boundaries before planning the work.
-
Why must airflow disturbance be controlled when changing SPS5785 51198651-100?Particles introduced during work can enter the working supply and cause a second failure. Keep the service area and remaining airflow protected.
-
When should a working SPS5785 51198651-100 be considered for planned exchange?Review supplies nearing the ten-year maintenance benchmark and schedule replacement during approved downtime where possible. Apply the xPM service procedure.
-
Which older black supply is distinguished from SPS5785 51198651-100 in the maintenance guidance?The black 51109456-200 supply is covered by priority replacement guidance concerning possible overvoltage. Verify the installed label before applying the corresponding procedure.
-
What wiring evidence should accompany service on SPS5785 51198651-100?Retain the feed identity, grounding and alarm-contact wiring, together with the supply part number and revision, so the power system can be restored and checked.
-
What should be checked after completing authorized work on SPS5785 51198651-100?Verify the power-system indications, alarm wiring, grounding, covers and closed doors. Confirm that conductive debris has been removed through the approved site process.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.