MC-TAMR03 51309218-175

LLMux RTD field termination assembly
In Stock
Ships by Monday, September 21
Fast Shipping Available

Product Describe:

Honeywell MC-TAMR03 is a conformally coated 16-channel LLMux RTD field termination assembly with compression terminals. Its part number is 51309218-175.

Ask our team:

Get a quick price for: MC-TAMR03 51309218-175
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for MC-TAMR03 51309218-175

Technical specifications for MC-TAMR03 51309218-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS System
  • Spare Part Number:
    51309218-175
  • Estimated shipping dimensions:
    30.7x12x6.8cm
  • Weight:
    0.98 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • FTA type:
    LLMux RTD
  • Input channels:
    16
  • Terminal type:
    Compression
  • Coating:
    Conformal coated
  • Compliance version:
    CE-compliant
  • LLMux IOP:
    MU-PLAM02 or MC-PLAM02

Information

Information

Overview Manuals Common Applications Product Precautions
Honeywell MC-TAMR03 51309218-175 is a field termination assembly for LLMux RTD signal wiring.
  • LLMux RTD termination
  • Temperature-signal marshalling
  • Cabinet-side field routing
  • System-specific terminal integration

MC-TAMR03 provides the termination path for the installed LLMux RTD measurement channels. Preserve the sensor lead arrangement, channel-to-terminal mapping and shield treatment shown on the project drawing; validate each channel with an approved simulated or known temperature input after service.

Important Notice: Confirm whether the matching I/O module, terminal assembly, cable set, field wiring and cabinet accessories required for MC-TAMR03 51309218-175 are included in the quotation or stock description.

Apter Power MC-TAMR03 Manuals and Guides

Important Notice: These are two separate Apter Power documents prepared from product-specific Honeywell technical information. Confirm the physical nameplate, current Honeywell documents and installed-system requirements before configuration or installation. They do not replace Honeywell manuals.

MC-TAMR03 installed-base replacement
Supports like-for-like maintenance of the documented LLMux RTD field termination assembly.
MC-TAMR03 compatibility review
Checks the host hardware, slot or mounting position, companion assembly, cable and revision before replacement.
MC-TAMR03 installation planning
Defines the required isolation, ESD, terminal, wiring and configuration checks before field work.
MC-TAMR03 commissioning
Supports controlled power, channel, communication, diagnostic and process-response checks after installation.
Read the applicable Honeywell instructions before work. Verify model MC-TAMR03, part number 51309218-175 and the installed-system configuration.
1
Verify model MC-TAMR03 and part number 51309218-175 on the physical label before use.
2
Use MC-TAMR03 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.
3
Match every MC-TAMR03 connector, terminal, cable and companion assembly before moving field wiring.
4
Back up the applicable controller, node, I/O or communication configuration before replacing MC-TAMR03.
5
Isolate energy before handling MC-TAMR03 unless the applicable hardware procedure explicitly permits energized service.
6
Follow ESD controls and protect MC-TAMR03 connectors and printed-circuit assemblies during handling.
7
Do not transfer channel, voltage, current, terminal or firmware values from a similar model to MC-TAMR03.
8
After installing MC-TAMR03, complete the relevant power, channel, link, diagnostic, alarm and fail-state checks.

Alternative Names

Alternative Names

MC-TAMR03 51309218-175

Technical notes

Technical notes

Use MC-TAMR03 with the exact Honeywell host, companion hardware, terminal assembly and field wiring specified for the installed system.

FAQS

  • Which sensor family is connected through MC-TAMR03?
    MC-TAMR03 is used with the llmux rtd field termination assembly input family shown on this page.
  • Which LLMux hardware must be matched to MC-TAMR03?
    Match MC-TAMR03 to the documented LLMux IOP, power adapter, cable and other LLMux FTAs; do not mix it with RHMUX assemblies.
  • How should temperature channels be checked after installing MC-TAMR03?
    Verify sensor type, lead configuration, channel assignment, cold-junction arrangement where applicable, scaling and open-sensor diagnostics.
  • What fta type value applies to MC-TAMR03?
    For MC-TAMR03, the listed fta type value is LLMux RTD. Confirm the same marking and configuration on the installed unit before work.
  • What input channels value applies to MC-TAMR03?
    For MC-TAMR03, the listed input channels value is 16. Confirm the same marking and configuration on the installed unit before work.
  • What terminal type value applies to MC-TAMR03?
    For MC-TAMR03, the listed terminal type value is Compression. Confirm the same marking and configuration on the installed unit before work.
  • What coating value applies to MC-TAMR03?
    For MC-TAMR03, the listed coating value is Conformal coated. Confirm the same marking and configuration on the installed unit before work.
  • What compliance version value applies to MC-TAMR03?
    For MC-TAMR03, the listed compliance version value is CE-compliant. Confirm the same marking and configuration on the installed unit before work.
  • Is MC-TAMR03 compatible with every Honeywell rack or chassis?
    No. Match MC-TAMR03 to the exact Honeywell host, rack or chassis, slot, companion hardware and project revision used by the installed system.
  • What installation checks are required for MC-TAMR03?
    Confirm isolation, ESD controls, slot or mounting position, connector orientation, terminal hardware, cable code and field wiring before installation.
  • Which fault information helps troubleshoot MC-TAMR03?
    Record MC-TAMR03 indicators, diagnostics, affected channels, field measurements, wiring checks, companion hardware and the sequence that produced the fault.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.