Speak to a sourcing specialist
sales13@apterpower.com

8C-TAOXB1 51307137-175

Series 8 Redundant Analog Output IOTA
In Stock
Ships by Saturday, November 7
Fast Shipping Available
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

Honeywell 8C-TAOXB1 51307137-175 is a conformally coated redundant Analog Output IOTA for the Series 8 platform. It provides the termination assembly used with the matched Series 8 analog output I/O module pair.
Get a quick price for 8C-TAOXB1 51307137-175
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 8C-TAOXB1 51307137-175

  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Spare Part Number:
    51307137-175
  • Estimated shipping dimensions:
    29.3x12x6.5cm
  • Weight:
    0.34 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Platform:
    Series 8
  • IOTA function:
    Analog output
  • Redundancy:
    Redundant
  • Coating:
    Conformally coated
  • Nominal IOTA size:
    12 in
  • Associated IOMs:
    8C-PAOHA1 / 8C-PAONA1
  • Output signal context:
    4-20 mA

Information

Overview Manuals Common Applications Product Precautions
Designed for the documented Series 8 redundant output architecture, this IOTA keeps field termination and paired-module service organized within the controller assembly.
  • Provides the redundant IOTA base for Series 8 analog-output assemblies
  • Keeps field wiring on a removable modular termination structure
  • Supports coated hardware selection for the documented Series 8 build
  • Accommodates either HART-capable or non-HART analog-output IOM pairing

Mount 8C-TAOXB1 51307137-175 in the approved Series 8 redundant analog-output assembly and verify the paired IOM type before landing field conductors. Confirm field supply, channel assignments, redundancy status and configured safe-state behavior before placing outputs in service.

Important Notice: Verify the complete model and item number, the Series 8 carrier arrangement, both IOM hardware types, field terminal assignments, 24 Vdc supply, shield treatment, FAILOPT configuration, redundancy health and a controlled loop test before commissioning.

Apter Power 8C-TAOXB1 51307137-175 Manuals and Guides

The first document is a model-specific engineering data reference. The second is a distinct installation and commissioning workbook with field checks and acceptance records.

Redundant process-control outputs
Terminates paired analog-output channels used to command final control elements in a Series 8 controller installation.
HART device output architecture
Works with the documented HART analog-output IOM when the project requires digital device communication over the current loop.
Non-HART current-loop service
Provides the redundant IOTA foundation for conventional Series 8 analog current outputs.
Controller migration panel work
Supports controlled replacement of the IOTA while preserving the approved Series 8 wiring and redundancy design.
Read the applicable Honeywell installation information before work. Verify 8C-TAOXB1 51307137-175 and the installed Series 8 Redundant Analog Output IOTA configuration before isolation, wiring or commissioning.
1
Confirm both the 8C-TAOXB1 and 51307137-175 markings before work.
2
Isolate field power and place controlled outputs in a safe operating state.
3
Apply ESD controls before removing either redundant IOM.
4
Record terminal, shield and field-supply assignments before disconnecting conductors.
5
Match the replacement IOTA to the configured HART or non-HART IOM pair.
6
Inspect the modular field connectors and redundant mating positions before insertion.
7
Restore the configured redundancy and FAILOPT behavior before releasing outputs.
8
Prove each affected 4-20 mA loop under controlled commissioning conditions.

Technical notes

Mount 8C-TAOXB1 51307137-175 in the approved Series 8 redundant analog-output assembly and verify the paired IOM type before landing field conductors. Confirm field supply, channel assignments, redundancy status and configured safe-state behavior before placing outputs in service.

FAQ View All FAQ

  • Which control platform uses 8C-TAOXB1 51307137-175?
    It is identified in Honeywell Series 8 documentation as a redundant analog-output IOTA.
  • Can a HART analog-output module be paired with 8C-TAOXB1 51307137-175?
    The official Series 8 specification lists the 8C-PAOHA1 HART analog-output IOM with this redundant IOTA type.
  • Can a non-HART analog-output module be paired with 8C-TAOXB1 51307137-175?
    The specification also lists the 8C-PAONA1 analog-output IOM for the documented IOTA family.
  • What should be recorded before rewiring 8C-TAOXB1 51307137-175?
    Record terminal positions, field supply, shield treatment, paired IOM positions and configured channel ownership.
  • How should redundancy be checked after replacement of 8C-TAOXB1 51307137-175?
    Confirm both IOMs are recognized, the redundant pair is healthy, and a controlled output transfer behaves as engineered.
  • What coating status is specified for 8C-TAOXB1 51307137-175?
    Honeywell identifies this IOTA as conformally coated.
  • What output signal context applies to 8C-TAOXB1 51307137-175?
    The associated Series 8 analog-output functions use 4-20 mA current loops.
  • What commissioning check is required for 8C-TAOXB1 51307137-175?
    Verify channel mapping, safe-state configuration, current-loop response and redundant-pair status before process release.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.