Technical specifications for F60 GEH 01

  • Manufacturer:
    HIMA
  • Product Category:
    DCS Systems
  • Spare Part Number:
    F60 GEH 01
  • Estimated shipping dimensions:
    26x21.5x31cm
  • Weight:
    2.8 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Product family:
    HIMatrix F60
  • Product class:
    Modular PES housing
  • I/O module slots:
    6
  • Integrated signal channels:
    None
  • System engineering:
    SILworX
  • Safety networking:
    Provided by installed controller modules
  • Selection boundary:
    Housing identity does not define the fitted module set

Information

Overview Manuals Common Applications Product Precautions
The F60 GEH 01 provides the six-position mechanical and bus structure used to assemble a modular HIMatrix F60 safety controller.
  • Confirm the exact F60 GEH 01 housing and its six I/O-module positions.
  • Record every fitted module and slot before disturbing the assembly.
  • Inspect the housing bus and module guides before reinsertion.
  • Do not describe the empty housing as a CPU, power supply or I/O module.

The housing supports an assembled F60 configuration; its operational role depends on the separately selected power supply, CPU and I/O modules installed in the approved slot arrangement.

Important Notice: F60 GEH 01 is the housing only; verify the complete fitted CPU, power-supply and I/O-module set separately.

HIMA F60 GEH 01 Manuals & Downloads
HIMA F60 GEH 01 Technical Reference (PDF)HIMA F60 GEH 01 Installation & Commissioning Guide (PDF)

The technical reference consolidates exact product data and evidence boundaries. The installation guide organizes controlled replacement, wiring or network checks, commissioning and acceptance.

Modular safety controller
Build an F60 system with separately documented processing and I/O modules.
Six-slot I/O assembly
Organize up to six I/O-module positions in the approved housing.
Controlled spare replacement
Replace a damaged housing while preserving every fitted module identity.
Cabinet modernization
Restore the original F60 slot map during a controlled hardware intervention.
HIMA F60 GEH 01 installation checks: preserve the exact model identity, documented system arrangement and controlled acceptance evidence.
1
Verify the complete manufacturer and model marking against the approved bill of materials.
2
Record the installed position, terminal arrangement, network assignment and visible diagnostics before removal.
3
De-energize the affected circuit and apply the site isolation and electrostatic-control procedure.
4
Compare every conductor, connector and address with the controlled drawing before transfer.
5
Inspect mating parts, grounding, shielding and enclosure condition before installing the replacement.
6
Restore only the validated project and the documented channel or communication settings.
7
Review startup diagnostics before any live functional test is attempted.
8
Prove the intended response and retain the witnessed acceptance record before release.

Technical notes

Retain a slot-by-slot record of every installed F60 module and inspect the backplane interfaces before reassembly.

FAQ View All FAQ

  • What is HIMA F60 GEH 01?
    HIMA F60 GEH 01 is the housing for a modular HIMatrix F60 programmable electronic system.
  • How many I/O-module slots does HIMA F60 GEH 01 provide?
    The exact housing provides six slots for separately selected F60 I/O modules.
  • Does HIMA F60 GEH 01 include the CPU module?
    No. The CPU module is a separate installed component and must be identified from the actual assembly record.
  • Does HIMA F60 GEH 01 include its power-supply module?
    No. The power supply is installed separately and is not defined by the housing identity alone.
  • Does HIMA F60 GEH 01 define the fitted I/O channel count?
    No. The channel count depends on the six separately installed I/O modules.
  • What should be recorded before dismantling HIMA F60 GEH 01?
    Create a slot-by-slot record of the CPU, power supply, I/O modules, connectors, network assignments and visible diagnostics.
  • What must be inspected when rebuilding HIMA F60 GEH 01?
    Inspect the housing, backplane interfaces, module guides, grounding and every connector before seating the modules in their recorded positions.
  • What completes acceptance of HIMA F60 GEH 01?
    Confirm the restored module population, power-up diagnostics, network state and witnessed functions of the assembled F60 system.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.