Technical specifications for IC754VGI06STD
-
Manufacturer:General Electric
-
Product Category:HMI Panels
-
Spare Part Number:IC754VGI06STD
-
Weight:4.54 kg
-
Tariff Code:8537101190
-
Interface family:6-inch QuickPanel View
-
Display technology:5.7-inch color passive STN
-
Display resolution:320 × 240 pixels
-
Display colors:65,536
-
Touch input:12-bit resistive, calibrated 320 × 240 cell grid
-
DC supply:10.8–30 V DC; nominal real power 12 W
-
Ethernet:IEEE 802.3, 10/100Base-T RJ45
-
Serial COM1:EIA-232C / EIA-485; 300–115,200 bit/s
-
Processor:Intel XScale PXA255, 300 MHz
-
DRAM:32 MB installed
-
Flash memory:32 MB total; OS and user storage areas
-
Battery-backed SRAM:512 KB
-
CompactFlash:One Type II slot
-
Expansion bus:One slot
-
Color-model operating range:0 to 60 °C
Information
- GE Fanuc IC754VGI06STD is the color-STN execution of the six-inch QuickPanel View, providing a local operator screen for the installed Machine Edition application.
Wiring review: Identify DC supply, serial mode and Ethernet topology before changeover
Acceptance path: Calibrate touch input and check each operator command against the machine
An Intel XScale PXA255 processor runs Windows CE.NET and the local application. The hardware includes 32 MB of DRAM, 512 KB of battery-backed SRAM, onboard flash storage, one Type II CompactFlash slot and an expansion bus. Retain the working project and any application files before disturbing storage or replacing the panel.
The panel provides 10/100Base-T Ethernet and a COM1 port configurable for EIA-232C or EIA-485 operation at 300–115,200 bit/s. Use a 10.8–30 V DC supply with allowance for startup inrush, then verify addresses, protocol settings, serial wiring, touch calibration and operator actions under controlled commissioning.
-
General Electric IC754
VGI06 STD technical reference Original manufacturer excerpt - PDF, 8 pages. Operator Interface Panel identity, interfaces and engineering scope. -
General Electric IC754
VGI06 STD installation guide Prepared by Apter Power - PDF, 5 pages. Preparation, installation, testing and handover for IC754VGI06 STD.
Application boundary: Screen objects, protocols and command effects are defined by the loaded Machine Edition project; the hardware model alone does not identify the connected PLC or control sequence.
-
Local operator display
Present process values, alarms and commands from the validated HMI application on the color touch display, with calibrated touch targets. -
Ethernet-connected supervision
Exchange application data across the 10/100Base-T port after checking addressing, cabling and the configured device protocol. -
Serial equipment interface
Use COM1 in its selected EIA-232C or EIA-485 mode with the correct cable pinout, baud rate and peer-device settings. -
Service-file transfer
Use approved CompactFlash or engineering-workstation transfer procedures to restore project files and retained settings during panel replacement.
Disconnect the supply before opening the panel or expansion cover. Confirm polarity, 10.8–30 V DC range, grounding and inrush capacity before energizing.
Back up the Machine Edition application, runtime settings, network addresses and any retained files. Keep a known working copy before altering flash or CompactFlash storage.
Confirm the complete IC754VGI06STD marking and color-STN panel. Monochrome MTD units have different display characteristics and must not be assumed equivalent.
Document Ethernet addressing and COM1 electrical mode, pinout and baud rate; a visually matching cable does not prove protocol compatibility.
Use a blunt stylus if needed, avoid sharp tools, and recalibrate the resistive screen after installation or persistent touch-position errors.
Test critical screens, alarms, command permissives and connected-controller responses in a controlled state before returning operators to normal use.
Alternative Names
Technical notes
Power and grounding: Connect the DC supply through the three-terminal power plug with the frame-ground conductor. The original guide specifies 10.8–30 V DC and a nominal 12 W real-power requirement; account for startup inrush in supply selection.
Application transfer: Retain the approved Machine Edition project and network settings before replacement. Verify COM1 mode, Ethernet address, display calibration and retained data after commissioning.
Technical reference: GE Fanuc 6-inch QuickPanel View Hardware User's Guide, GFK-2326, May 2004. Its color-STN variant information applies to IC754VGI06STD; software-project behavior remains installation-specific.
FAQ View All FAQ
-
What should be reviewed before transferring a monochrome HMI project to IC754VGI06STD?IC754VGI06STD is the color-STN STD panel, while MTD entries describe monochrome variants. Review the project's screen dimensions, color use, target hardware and runtime compatibility before transfer; prove the displayed screens and touch targets on the actual panel.
-
How should the power circuit be checked before IC754VGI06STD is energized?Measure the supply at the panel under the expected load and verify the 10.8–30 V DC input range, nominal 12 W demand and startup inrush allowance. Connect the frame ground and confirm polarity and protective wiring before first power-up.
-
How should the Ethernet and COM1 paths of IC754VGI06STD be validated with the PLC?The panel has 10/100Base-T Ethernet and a COM1 interface selectable for EIA-232C or EIA-485. Confirm the actual project protocol, IP or serial settings, cable pinout and PLC data map, then verify live values and operator commands end to end.
-
Why is a matching baud rate alone insufficient for COM1 communication on IC754VGI06STD?COM1 supports 300–115,200 bit/s, but communication also depends on the selected EIA-232C or EIA-485 electrical mode, cable pinout, framing, node settings and protocol used by the project and peer device. Check all of those before diagnosing a failed link as a port fault.
-
How is the touch screen on IC754VGI06STD commissioned?Use the panel calibration procedure for the 12-bit resistive screen and verify targets across the display. Then test operator commands against the connected machine in an approved safe state.
-
How should an application be restored to IC754VGI06STD?Retain the validated Machine Edition project and runtime/network settings. Transfer the project by the approved workstation or CompactFlash procedure, then confirm screens, alarms, commands and PLC data on the actual installation.
-
What should be preserved before resetting or exchanging IC754VGI06STD?Retain the validated project, runtime and network settings and determine which application data reside in flash, battery-backed SRAM or removable CompactFlash. The 32 MB DRAM and 32 MB flash serve different purposes; preserve required data through the approved backup procedure before reset.
-
How should enclosure conditions be assessed for IC754VGI06STD?Check the actual enclosure temperature against the color model's 0–60 °C operating range, including internal heat rise during operation. Review ventilation, condensation risk, grounding and cable routing before commissioning rather than relying only on ambient room temperature.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
Related cases and sourcing guidance
View all case studiesYou May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.