Speak to a sourcing specialist
sales13@apterpower.com

DS200FSAAG1A

Field Supply Gate Amplifier Board
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE DS200FSAAG1A is a DC2000 FSAA single-phase field-supply gate amplifier board for a non-reversing plugging (NRP), with conditional NRX capability field bridge.
  • Manufacturer part number
    DS200FSAAG1A
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    25.5cm x 10.2cm x 3.1cm
  • Country of Origin
    USA
Get a quick price for DS200FSAAG1A
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete DS200FSAAG1A marking, installed revision, quantity and system configuration with your enquiry.

  • 1

    Confirm the offer

    Check that the quotation identifies DS200FSAAG1A, its offered condition, included parts and dispatch date.

  • 2

    Arrange dispatch

    Confirm the delivery details and receive tracking information when shipment is arranged.

  • Match the complete marking

    Include DS200FSAAG1A and every visible revision or serial identity in your enquiry. Keep the same complete reference on the quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered DS200FSAAG1A with the installed equipment and applicable GE documentation.

Technical specifications for DS200FSAAG1A

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    DS200FSAAG1A
  • Weight:
    0.38 kg
  • Tariff Code:
    8537101190
  • Board family:
    DC2000 FSAA field supply gate amplifier
  • Hardware group:
    G1: non-reversing plugging (NRP), with conditional NRX capability
  • Bridge arrangement:
    Four-SCR full-wave field supply bridge
  • SCR control:
    all four SCRs are phase-controlled
  • AC MOV placement:
    separate MOV subassembly
  • Input fuse positions:
    L2 and L3
  • Onboard fuse rating:
    30 A each
  • Protected field load:
    Up to 24 A via onboard fuses; larger fields need external fusing
  • Mode hardware:
    JP1–JP6 configuration positions
  • Board identification:
    Complete DS200FSAAG1A edge marking
  • Revision marking:
    A suffix

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE DS200FSAAG1A is part of the DC2000 field-supply firing path, controlling the SCR bridge that energizes the motor field in the installed drive.
Service sequence: Record bridge wiring and board marking before isolation
Protection review: Check L2/L3 fuses and the installed field-current arrangement
Release test: Verify field excitation and drive response under a controlled start
The FSAA board mounts on a four-SCR, full-wave single-phase field supply bridge. The G1 execution is intended for NRP field supplies and can be configured for NRX only under the original GE procedure when the NRP application has persistent field problems. Bridge wiring and the drive's field-control settings determine the final circuit behavior.

In this G1 group, all four SCRs are phase-controlled. The AC surge-protection MOV is mounted on a separate subassembly. These are hardware-group distinctions and must remain aligned with the actual SCR bridge when a board is exchanged.

Two 30 A onboard fuses protect the L2 and L3 lines. GE's instructions distinguish field loads through 24 A from larger fields that use external fuses to feed the field; verify the installed fuse coordination and record the as-left bridge connections before enabling operation.
Controller platform reference: GE DC2000 field supply. Match the SCR bridge and field wiring.
Technical downloads for General Electric DS200FSAAG1A: a product-specific Apter Power technical reference and an Apter Power installation and commissioning guide.
Both documents are prepared by Apter Power for the offered model. Check the complete marking and installed system before applying the engineering guidance.
Service DS200FSAAG1A only after the drive and field supply have been isolated and discharged. Preserve SCR, fuse and MOV relationships during replacement.
Make the field circuit safe

Apply the site lockout procedure to incoming power and the field supply. Verify stored energy is discharged before touching the board or bridge.

Control static discharge

Handle the printed board by its edges using grounded ESD protection; protect connectors and components during transport and insertion.

Match the complete board

Read the full DS200FSAAG1A edge marking and the installed bridge record. A G1 and G2 FSAA board have different SCR-control and MOV arrangements.

Check fusing before energizing

Inspect the L2/L3 30 A fuse positions and determine whether the field circuit needs larger external fuses under the original GE instructions.

Preserve mode hardware

Record JP1–JP6 configuration positions. Do not transfer settings from a neighboring group or assume board appearance defines the operating mode.

Test controlled excitation

After wiring verification, prove field voltage/current response, relevant drive alarms and protective operation at a safe test point before normal operation.

Alternative Names

GE DS200FSAAG1A GE Drive Systems DS200FSAAG1A General Electric DS200FSAAG1A

Technical notes

Field-supply relationship: The board is mounted on a four-SCR full-wave field bridge. In the G1 circuit, all four SCRs are phase-controlled. Keep the original bridge, firing leads and MOV arrangement with the installed drive configuration.

Protection and handling: L2/L3 input fuses are rated 30 A. The original instructions distinguish fields up to 24 A from larger applications that require external field fusing; isolate and discharge the equipment before board handling.

Technical reference: GE Drive Systems FSAA Single-phase Field Supply Gate Amplifier Board Replacement Instructions, GEI-100186, October 1994. The G1 group behavior is documented; the complete revision marking remains an installation identity that must be matched with the drive record.

FAQ View All FAQ

  • Why must the field bridge be reviewed together with DS200FSAAG1A during replacement?
    DS200FSAAG1A drives SCR firing in a four-SCR full-wave motor-field bridge; the board alone is not the complete excitation circuit. Compare bridge identity, wiring, field-current arrangement and drive controls before fitting the replacement, then prove controlled excitation under the site test plan.
  • How does the G1 hardware group constrain use of DS200FSAAG1A?
    G1 is used for non-reversing plugging and has conditional NRX capability. Confirm the installed field mode, JP1–JP6 configuration and bridge record; the complete suffix does not by itself establish how the drive is wired.
  • What bridge-firing difference must be checked before substituting DS200FSAAG1A?
    G1 phase-controls all four SCRs. Compare that behavior with the installed bridge and mode hardware; G2 instead phase-controls P1/N1 while P2/N2 turn on with positive anode voltage, so a visually similar board is not automatically interchangeable.
  • How should the AC surge-protection path be checked when fitting DS200FSAAG1A?
    For G1, the AC MOV is a separate subassembly. Confirm that it is present and connected in the installed bridge, and inspect the L2/L3 protection path before energizing; a G2 board carries its AC MOV onboard.
  • When does the field-current arrangement of DS200FSAAG1A require external fuse review?
    The board's L2/L3 onboard fuses are 30 A each. GE describes onboard protection for field loads up to 24 A; higher-current applications require external field fusing while the onboard fuses protect the MOV path. Verify the actual field load and cabinet fuse scheme against the drive drawing.
  • Can DS200FSAAG1A replace the other FSAA G group directly?
    Do not treat the G1 and G2 groups as direct substitutes. Their SCR firing behavior, MOV placement and mode hardware differ; use the drive and bridge record to evaluate any proposed change.
  • Which marking should be recorded before fitting DS200FSAAG1A?
    Record the complete DS200FSAAG1A edge marking, bridge identity, fuse data, connector positions and any mode hardware. Keep an as-found wiring record so the board can be returned to its original configuration.
  • How should DS200FSAAG1A be accepted after installation?
    Verify isolation is removed deliberately, check bridge connections and fuse continuity, then observe controlled field excitation and drive protection indications under a site-approved test plan.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.