GE Multilin SR760 760-P1-G1-S1-HI-A20-R combines feeder protection, control, metering and automatic reclosing in the specified option set. The order code selects 1 A current inputs, high-range auxiliary power, eight 4–20 mA outputs and a red breaker-closed indicator.
Get a quick price for SR760 760-P1-G1-S1-HI-A20-R
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for SR760 760-P1-G1-S1-HI-A20-R

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    SR760 760-P1-G1-S1-HI-A20-R
  • Estimated shipping dimensions:
    18x17.7x23cm
  • Weight:
    5.46 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Base relay:
    760 feeder management relay with autoreclose
  • Phase-current option:
    P1: 1 A phase current inputs
  • Zero-sequence option:
    G1: 1 A zero-sequence current input
  • Sensitive-ground option:
    S1: 1 A sensitive-ground current input
  • DC control power:
    HI: 88 to 300 V dc
  • AC control power:
    HI: 70 to 265 V ac, 48 to 62 Hz
  • Analog-output option:
    A20: eight 4 to 20 mA outputs
  • Breaker-closed indicator:
    R: red LED

Information

Overview Manuals Common Applications Product Precautions
GE Multilin SR760 760-P1-G1-S1-HI-A20-R is the autoreclose version of the 750/760 feeder-management platform, configured for 1 A phase, zero-sequence and sensitive-ground sources. Its HI supply accepts a broad ac/dc range, while the A20 option provides eight analog transducer outputs for control-room or plant-interface use.
  • SR760 feeder protection with autoreclose
  • P1, G1 and S1 one-ampere current-input options
  • HI wide-range ac/dc control power
  • Eight A20 4–20 mA analog outputs

The operating chain runs from Phase, ground and sensitive-ground CT circuits → SR760 measurement and protection elements → Trip / reclose control logic → Breaker, alarms and eight analog outputs; document each boundary and prove the intended final response before release.

Important Notice: Treat P1, G1, S1, HI, A20 and R as functional ordering selections; do not replace the relay from the SR760 family name alone.

GE SR760 760-P1-G1-S1-HI-A20-R Manuals & Downloads
GE SR760 760-P1-G1-S1-HI-A20-R Official Technical Reference Excerpt (PDF)GE SR760 760-P1-G1-S1-HI-A20-R Installation & Commissioning Guide (PDF)

The Official Technical Reference Excerpt retains the applicable GE Multilin ordering-code and manual-change pages for the configured SR760 relay. The independent commissioning guide covers CT safety, auxiliary power, settings restoration, trip/reclose tests and analog-output acceptance.

Feeder protection
Applies coordinated phase and ground protection to medium-voltage feeders.
Automatic reclosing
Supervises breaker trip and programmed reclose sequences.
Sensitive ground detection
Uses the S1 one-ampere input for low-level ground-fault measurement.
Plant analog integration
Transmits selected measurements over eight 4–20 mA output channels.
Apply these controls specifically to GE SR760 760-P1-G1-S1-HI-A20-R before isolation, replacement, reconnection, energization and final release.
1
Short and isolate CT secondary circuits before disconnecting GE SR760 760-P1-G1-S1-HI-A20-R.
2
Confirm all phase, zero-sequence and sensitive-ground sources are 1 A secondary circuits.
3
Verify the HI auxiliary supply is within the stated ac or dc range before energization.
4
Back up settings, logic, relay assignments, reclose sequence and calibration data before replacement.
5
Maintain CT polarity and phase order when reconnecting P1, G1 and S1 inputs.
6
Scale each A20 channel for 4–20 mA operation at the receiving system before loop testing.
7
Block breaker operation during secondary-injection and output-relay tests unless the approved plan requires movement.
8
Complete protection, trip, reclose, metering, LED and analog-output tests before service release.

Technical notes

Confirm each order-code segment against the relay label, CT secondary ratings, auxiliary supply, analog-output wiring and breaker indication. Restore the approved settings file and test protection, trip, reclose and all eight 4-20 mA outputs before service.

FAQ View All FAQ

  • What does the 760 code mean in GE SR760 760-P1-G1-S1-HI-A20-R?
    760 identifies the feeder-management relay version with autoreclose.
  • Which phase-current input is fitted to GE SR760 760-P1-G1-S1-HI-A20-R?
    P1 specifies 1 A phase-current inputs.
  • What do G1 and S1 select on GE SR760 760-P1-G1-S1-HI-A20-R?
    G1 selects a 1 A zero-sequence input and S1 selects a 1 A sensitive-ground input.
  • What control-power range applies to GE SR760 760-P1-G1-S1-HI-A20-R?
    HI accepts 88–300 V dc or 70–265 V ac at 48–62 Hz.
  • Which analog outputs are fitted to GE SR760 760-P1-G1-S1-HI-A20-R?
    A20 provides eight 4–20 mA analog outputs.
  • What does R identify on GE SR760 760-P1-G1-S1-HI-A20-R?
    R selects a red breaker-closed front-panel indicator.
  • Which data should be preserved before changing GE SR760 760-P1-G1-S1-HI-A20-R?
    Save the complete setting file, CT ratios, protection curves, logic, I/O map, reclose sequence, communications data and calibration records.
  • Which tests should accept GE SR760 760-P1-G1-S1-HI-A20-R?
    Perform current injection, phase/ground element checks, trip and reclose tests, metering verification and all eight 4–20 mA loop tests.
Related reading

Related cases and sourcing guidance

View all case studies
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.