Speak to a sourcing specialist
sales13@apterpower.com

750-P5-G5-S5-HI-A20-R-E

Feeder Management Relay
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

GE Multilin 750-P5-G5-S5-HI-A20-R-E is an enhanced-display 750 feeder management relay with 5 A phase, zero-sequence and sensitive-ground inputs and eight 4–20 mA analog outputs.
  • Manufacturer part number
    750-P5-G5-S5-HI-A20-R-E
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    16.8cm x 17.7cm x 23cm
  • Country of Origin
    USA
Get a quick price for 750-P5-G5-S5-HI-A20-R-E
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete 750-P5-G5-S5-HI-A20-R-E marking, installed revision, quantity and system configuration with your enquiry.

  • 1

    Confirm the offer

    Check that the quotation identifies 750-P5-G5-S5-HI-A20-R-E, its offered condition, included parts and dispatch date.

  • 2

    Arrange dispatch

    Confirm the delivery details and receive tracking information when shipment is arranged.

  • Match the complete marking

    Include 750-P5-G5-S5-HI-A20-R-E and every visible revision or serial identity in your enquiry. Keep the same complete reference on the quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 750-P5-G5-S5-HI-A20-R-E with the installed equipment and applicable GE documentation.

Technical specifications for 750-P5-G5-S5-HI-A20-R-E

  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    750-P5-G5-S5-HI-A20-R-E
  • Weight:
    4.96 kg
  • Tariff Code:
    8537101190
  • Relay family:
    750 feeder management
  • Phase CT inputs:
    P5: 5 A
  • Zero-sequence CT input:
    G5: 5 A
  • Sensitive-ground CT input:
    S5: 5 A
  • Control supply:
    HI: 88–300 V DC or 70–265 V AC, 48–62 Hz
  • Analog outputs:
    A20: eight 4–20 mA outputs
  • Breaker-closed indicator:
    R: red LED
  • Front display:
    E: enhanced LCD
  • Protection role:
    Feeder protection and monitoring
  • Setup software:
    EnerVista 750/760 Setup; version matched to firmware
  • Firmware check:
    Read actual revision before importing settings

Information

Overview Downloads Applications / Compatibility Product Precautions
  • GE Multilin 750-P5-G5-S5-HI-A20-R-E brings phase, zero-sequence and sensitive-ground measurements into a 750 feeder-protection scheme, with an enhanced front-panel interface for local review.
Commissioning focus: Reconcile CT circuits, auxiliary supply and the saved feeder settings
Output review: Prove each wired analog destination against the channel scaling
Handover record: Capture firmware, event settings and the complete relay marking
The P5, G5 and S5 input options accept separate 5 A current-transformer circuits for phase, zero-sequence and sensitive-ground measurement. Their polarity, ratios and associated protection settings are application choices; the relay order code alone does not establish a feeder pickup value or trip delay.

The HI supply option covers 88–300 V DC or 70–265 V AC at 48–62 Hz. The R option provides a red breaker-closed indicator, while the E execution uses the enhanced LCD and its revised navigation. Record the installed firmware before transferring settings between units.

Its A20 group provides eight 4–20 mA analog outputs. Loop scaling, receiver input and break detection must match the actual analog channel settings. Feeder trip, alarm and metering behavior follows the configured relay logic and actual wiring; exercise the protection functions under an approved test plan before returning the circuit to service.
Controller platform reference: GE Multilin 750 feeder management. Preserve the saved settings and CT schedule.
Technical downloads for General Electric 750-P5-G5-S5-HI-A20-R-E: a manufacturer technical excerpt and an Apter Power installation and commissioning guide.
The technical reference preserves selected manufacturer pages. The installation guide provides a model-specific field workflow; use the installed equipment instructions and site controls during work.
Commission 750-P5-G5-S5-HI-A20-R-E as a protection device: isolate the feeder where required, preserve the approved settings and test every connected trip and analog path before return to service.
Control CT secondaries

Follow the site CT isolation and shorting procedure before opening current circuits. Confirm phase, zero-sequence and sensitive-ground inputs are landed on the intended terminals.

Match the auxiliary supply

Verify the available control voltage and frequency fall inside the HI option range before energizing the relay; do not infer the supply from another 750 relay in the cubicle.

Save the setting record

Export settings and record firmware, CT ratios, breaker logic, protection elements and event settings before replacement. Review differences before importing an archived file.

Prove analog scaling

Test every assigned 4–20 mA output at meaningful low, mid and high indications, checking receiver scaling, polarity and channel mapping.

Check trip circuits

Place the breaker in the approved maintenance state; test alarm and trip outputs through the site protection procedure before release.

Verify panel indication

Compare the red breaker-closed LED and enhanced-display status with actual breaker contacts and control-system indications after commissioning.

Alternative Names

GE 750-P5-G5-S5-HI-A20-R-E GE Multilin 750-P5-G5-S5-HI-A20-R-E General Electric 750-P5-G5-S5-HI-A20-R-E

Technical notes

Installation relationship: Connect the P5, G5 and S5 current inputs to their corresponding 5 A CT circuits. Match the HI control supply to the available source and validate the trip/close wiring before energizing.

Analog interface: The A20 option supplies eight 4–20 mA analog outputs. Configure each receiver for the selected channel range and verify end-to-end scaling against the feeder engineering record.

Technical reference: GE Multilin 750/760 Firmware 6.00 Release Details, GER-4012, and 750/760 Feeder Management Relay brochure. The order code defines the offered hardware options; settings and operational behavior depend on installed firmware and configuration.

FAQ View All FAQ

  • How should the three CT circuits be mapped and proven when commissioning 750-P5-G5-S5-HI-A20-R-E?
    Map the phase, zero-sequence and sensitive-ground circuits separately to their matching relay inputs. Compare each CT ratio, polarity and secondary wiring with the feeder drawing, then inject or otherwise prove each measurement path before enabling protection.
  • What must be checked before applying auxiliary power to 750-P5-G5-S5-HI-A20-R-E?
    Measure the panel's actual AC or DC auxiliary source and verify that it falls within the HI option range of 88–300 V DC or 70–265 V AC at 48–62 Hz. Check upstream protection and terminal polarity or phase connections before energizing; a different 750 supply option is not a safe reference.
  • How should the 4–20 mA analog channels of 750-P5-G5-S5-HI-A20-R-E be mapped to plant receivers?
    Confirm the configured quantity and engineering scale for each of the eight 4–20 mA channels, then compare the wiring and receiving-device input range channel by channel. Prove low, intermediate and high indications at the destination; an unassigned channel or mismatched input range can give a plausible but incorrect reading.
  • Does 750-P5-G5-S5-HI-A20-R-E provide 760 autoreclose functions?
    No 760 identity is present in this order code. Plan autoreclose only when the installed protection design provides it through a separately identified device or scheme.
  • How can the breaker-closed indication on 750-P5-G5-S5-HI-A20-R-E be proved against the field circuit?
    Operate the breaker in an approved test state and compare the red indicator with the actual auxiliary contact, relay input logic and control-system indication. The indicator color alone does not establish contact polarity or prove a correctly wired status circuit.
  • How should settings be moved into 750-P5-G5-S5-HI-A20-R-E?
    Record the original relay firmware and export its setting file. Compare CT ratios, element enables, time curves, I/O mappings and software compatibility before loading, then test the affected protection functions.
  • What should be verified at the front panel when replacing 750-P5-G5-S5-HI-A20-R-E?
    Confirm that the installed unit has the E enhanced display and that its navigation, displayed measurements, alarms and breaker status agree with the commissioned relay configuration. The display is an identity and operating check; the full order code and fitted firmware still govern replacement review.
  • Which acceptance tests are essential for 750-P5-G5-S5-HI-A20-R-E?
    Verify the three CT input groups, HI supply, breaker indication, assigned protection trips and all used 4–20 mA analog outputs. Record as-found and as-left values under the site's protection-test procedure.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.