Technical specifications for PR6426-000-030
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:PR6426-000-030
-
Estimated shipping dimensions:25x20x4.5cm
-
Weight:0.85 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Sensor family:PR6426
-
Sleeve thread:None
-
Armor:No
-
Mounting plate:80 x 40 mm
-
Adapter plug:Included
-
Total cable length:8 m
-
Cable end:LEMO
-
Static nominal range:+/-4.0 mm
-
Sensitivity:2 V/mm
-
Nominal distance center:Approximately 5.5 mm
-
Basic air gap:1.2 to 1.8 mm
-
Operating temperature:-35 to +150 degC
-
Vibration endurance:5 g at 60 Hz
Information
- Provides an eight-millimetre nominal static span
- Mounts through an 80 x 40 mm plate
- Uses an eight-metre unarmored lead
- Connects to a PR6426-calibrated converter
PR6426-000-030 operates with PR6426-configured CON021 or CON041, 80 x 40 mm mounting plate, Large conductive target, Compatible position-monitoring channel.
Engineered applications include Large axial-displacement measurement, Valve and actuator position, Large-clearance shaft position, Slow mechanical movement monitoring.
Important Notice: Verify mounting-plate flatness, the eight-metre cable system and PR6426 converter calibration; set the larger gap only after the target and bracket are mechanically stable.
Apter Power PR6426-000-030 Manuals and Guides
Apter Power PR6426-000-030 Measurement-System Technical Reference PDFApter Power PR6426-000-030 Installation, Loop Check and Acceptance Workbook PDFThe first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Large axial-displacement measurement
Measures displacement where a wider static span is required.
Valve and actuator position
Tracks controlled movement of large conductive targets.
Large-clearance shaft position
Supports large-clearance shaft-position observation.
Slow mechanical movement monitoring
Provides non-contact measurement of slow expansion or movement.
Verify the complete PR6426-000-030 order code, 80 x 40 mm mounting plate mounting interface and assigned PR6426 32 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6426-000-030.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 8 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
Technical notes
FAQ View All FAQ
-
What measurement or system function does PR6426-000-030 perform?PR6426-000-030 is a pr6426 large-range eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
-
Which installed hardware must be paired with PR6426-000-030?Use PR6426-000-030 with the documented Emerson PR6426 32 mm eddy-current measurement system components: PR6426-configured CON021 or CON041, 80 x 40 mm mounting plate, Large conductive target.
-
How should the Sensor family value for PR6426-000-030 be verified?Confirm the complete nameplate and order code before work; the documented sensor family is PR6426.
-
What connection detail is critical when installing PR6426-000-030?Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
-
How is PR6426-000-030 mechanically installed without changing measurement behavior?Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
-
What commissioning test should be completed for PR6426-000-030?Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
-
What configuration record should be retained when replacing PR6426-000-030?Retain the as-found position, sleeve thread, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
-
Can PR6426-000-030 replace a similar Emerson model without engineering review?No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved Emerson PR6426 32 mm eddy-current measurement system configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.