Technical specifications for PR6423-010-000
-
Manufacturer:Emerson
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:PR6423-010-000
-
Estimated shipping dimensions:16x15x4cm
-
Weight:0.3 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Sensor family:PR6423
-
Sleeve thread:M10 x 1
-
Armor:Yes
-
Probe length Cx:25 mm
-
Overall sensor length C:34 mm
-
Adapter plug:Included
-
Total cable length:4 m
-
Cable end:LEMO
-
Static nominal range:+/-1.0 mm
-
Recommended dynamic range:50 to 500 um p-p
-
Sensitivity:8 V/mm
-
Nominal distance center:Approximately 1.5 mm
-
Basic air gap:0.4 to 0.7 mm
-
Operating temperature:-35 to +180 degC; +200 degC short term
-
Pressure at sensor head:10,000 hPa
-
Vibration endurance:5 g at 60 Hz
Information
- Uses a compact 25 mm armored probe body
- Includes a four-metre integral cable
- Provides the PR6423 two-millimetre static span
- Connects through the standard LEMO termination
PR6423-010-000 operates with PR6423-configured CON021 or CON041, M10 x 1 mounting bracket, Conductive shaft target, Compatible vibration or position monitor.
Engineered applications include Compact bearing radial vibration, Short-bracket thrust position, Pump shaft centerline monitoring, Eccentricity channels.
Important Notice: Verify the compact 25 mm body clearance, M10 x 1 thread, armored four-metre cable and PR6423 converter calibration before setting the operating gap.
Apter Power PR6423-010-000 Manuals and Guides
Apter Power PR6423-010-000 Measurement-System Technical Reference PDFApter Power PR6423-010-000 Installation, Loop Check and Acceptance Workbook PDFThe first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Compact bearing radial vibration
Fits compact bracket spaces while retaining PR6423 measurement behavior.
Short-bracket thrust position
Monitors axial movement at short probe mounting points.
Pump shaft centerline monitoring
Supports non-contact journal-position trending.
Eccentricity channels
Measures slow-roll shaft bow with a protected lead.
Verify the complete PR6423-010-000 order code, M10 x 1 mounting interface and assigned PR6423 8 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6423-010-000.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 4 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
Technical notes
FAQ View All FAQ
-
What measurement or system function does PR6423-010-000 perform?PR6423-010-000 is a pr6423 8 mm eddy-current displacement sensor. It senses shaft-to-probe displacement for a matched Emerson signal converter and machinery-monitoring channel.
-
Which installed hardware must be paired with PR6423-010-000?Use PR6423-010-000 with the documented Emerson PR6423 8 mm eddy-current measurement system components: PR6423-configured CON021 or CON041, M10 x 1 mounting bracket, Conductive shaft target.
-
How should the Sensor family value for PR6423-010-000 be verified?Confirm the complete nameplate and order code before work; the documented sensor family is PR6423.
-
What connection detail is critical when installing PR6423-010-000?Preserve every conductor, connector and shield identity, then follow the model-specific connection arrangement described in the controlling Emerson document.
-
How is PR6423-010-000 mechanically installed without changing measurement behavior?Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
-
What commissioning test should be completed for PR6423-010-000?Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.
-
What configuration record should be retained when replacing PR6423-010-000?Retain the as-found position, sleeve thread, cable or channel identity, gap or scaling value, diagnostics and final functional-test result.
-
Can PR6423-010-000 replace a similar Emerson model without engineering review?No direct substitution should be assumed; verify the full order code, measuring function, interface, cable or channel arrangement and the approved Emerson PR6423 8 mm eddy-current measurement system configuration.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.