PR6423-010-000 operates with PR6423-configured CON021 or CON041, M10 x 1 mounting bracket, Conductive shaft target, Compatible vibration or position monitor.
Engineered applications include Compact bearing radial vibration, Short-bracket thrust position, Pump shaft centerline monitoring, Eccentricity channels.
Important Notice: Verify the compact 25 mm body clearance, M10 x 1 thread, armored four-metre cable and PR6423 converter calibration before setting the operating gap.
The first document provides model-specific technical and measurement-system reference data. The second is a separate field workbook for mounting, wiring, commissioning and acceptance records.
Fits compact bracket spaces while retaining PR6423 measurement behavior.
Monitors axial movement at short probe mounting points.
Supports non-contact journal-position trending.
Measures slow-roll shaft bow with a protected lead.
Verify the complete PR6423-010-000 order code, M10 x 1 mounting interface and assigned PR6423 8 mm eddy-current system measuring point before work.
Place the monitored machine and its protection channel in the approved maintenance state before disturbing PR6423-010-000.
Protect the probe tip from impact and keep the mounting thread and bracket free from burrs or contamination.
Route the 4 m sensor lead without sharp bends, crushing, tensile load or contact with hot and moving surfaces.
Keep the LEMO or open-end connection clean, dry and fully identified before reconnecting the measurement loop.
Confirm the paired signal converter or monitor input, cable length and target material match the documented measuring chain.
Set the static gap within the documented linear region while preserving shaft and probe mechanical clearance.
Prove polarity, static gap, dynamic response and alarm action before returning the protection channel to service.