Match the complete marking
Include KJ4001X1-BA2 VE3051C0 12P1562X042 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered KJ4001X1-BA2 VE3051C0 12P1562X042 with the installed equipment and applicable Emerson documentation.
Technical specifications for KJ4001X1-BA2 VE3051C0 12P1562X042
-
Manufacturer:Emerson
-
Product Category:DCS Systems
-
Spare Part Number:KJ4001X1-BA2 VE3051C0 12P1562X042
-
Weight:0.25 kg
-
Tariff Code:8537101190
-
Product type:2-wide power/controller carrier
-
Carrier type number:KJ4001X1-BA2
-
Ordering reference:VE3051C0
-
Supplied assembly reference:12P1562X042
-
System family:DeltaV horizontal I/O
-
Carrier capacity:One system power supply and one controller, or two system power supplies
-
Simplex controller position:Right-hand slot
-
Adjacent carrier connection:48-pin side connectors
-
DIN rail profile, BA2 arrangement:35 mm T- or G-type
-
Recommended T-rail depth:15 mm
-
Carrier position:To the left of 8-wide I/O carriers
-
Redundant controller arrangement:Additional power/controller carrier required
Information
- Emerson KJ4001X1-BA2 VE3051C0 12P1562X042 provides the carrier position for DeltaV controller power and the adjoining horizontal I/O subsystem.
Capacity: One system power supply plus one controller, or two system power supplies
Carrier connection: Side-mounted 48-pin connections
The BA2 installation arrangement uses standard 35 mm T- or G-type DIN rail, with different latching screws for the two rail profiles. The heavier 15 mm-deep T rail is recommended for the equipment weight distribution. Adjacent carriers connect by sliding their side-mounted 48-pin connectors together, and the 2-wide carrier is positioned to the left of the 8-wide I/O carriers. Latch engagement and connector alignment must both be established before installing the mounted modules.
The horizontal-carrier system carries power and communication between the controller and I/O interfaces. A redundant controller requires an additional carrier; redundancy is a system arrangement involving the selected controllers, supplies and connections. Carrier extensions support layouts across separate rails, while grounding follows the installed enclosure and power-system design. Keep the supplied BA2 and X042 assembly identity distinct from later carrier revisions when selecting a replacement.
-
Emerson KJ4001X1-BA2 VE3051C0 12P1562X042 technical reference
Prepared by Apter Power - PDF, 5 pages, 25.6 KB. Technical summary of verified DeltaV M-series design functions and applicable configuration boundaries. -
Emerson KJ4001X1-BA2 VE3051C0 12P1562X042 installation planning guide
Prepared by Apter Power - PDF, 5 pages, 25.5 KB. Installation planning, system integration and controlled acceptance checks.
Platform applications: The following applications describe DeltaV M-series functions. Match the complete KJ4001X1-BA2 VE3051C0 12P1562X042 identity to the installed system before selecting a replacement.
-
Simplex controller mounting
Mount the controller in the right-hand carrier position with the matched system power supply. The carrier establishes the mechanical and electrical connection to the horizontal subsystem. -
System power arrangement
The two positions can carry one supply and one controller, or two supplies. Select the installed power architecture and verify the companion modules separately. -
Horizontal I/O integration
Connect the carrier to the adjoining horizontal I/O carriers through the side connections. Keep the 2-wide carrier to the left of the 8-wide I/O group. -
Redundant-system maintenance
A redundant controller requires an additional carrier and the appropriate controller and power arrangement. Preserve the complete system topology during replacement.
Retain KJ4001X1-BA2, VE3051C0 and 12P1562X042 together. Confirm the assembly label and connectors against the installed carrier before ordering or replacement.
The BA2 arrangement uses different latching screws for T- and G-type rail. Confirm the rail profile and engage the correct latches under the original installation procedure.
Inspect the 48-pin carrier connections and align adjacent carriers before fastening. Do not force misaligned or damaged contacts into engagement.
Install the 2-wide power/controller carrier to the left of 8-wide I/O carriers. The simplex controller uses the right-hand position on its carrier.
Verify the selected power-supply modules, grounding and enclosure wiring. Isolate all affected sources before disturbing carrier connections; module hot-swap capability does not establish permission to remove the carrier live.
After installation, verify controller status, I/O communication and the approved redundancy arrangement before returning the process system to service. Apply the actual module and system instructions.
Alternative Names
Technical notes
Installation relationship: The BA2 installation arrangement uses standard 35 mm T- or G-type DIN rail, with different latching screws for the two rail profiles. The heavier 15 mm-deep T rail is recommended for the equipment weight distribution. Adjacent carriers connect by sliding their side-mounted 48-pin connectors together, and the 2-wide carrier is positioned to the left of the 8-wide I/O carriers. Latch engagement and connector alignment must both be established before installing the mounted modules.
Configuration: BA2 installation details apply to the carrier design; VE3051C0 identifies the 2-wide ordering configuration. Confirm the supplied 12P1562X042 assembly and installed-system revision.
Technical reference: Emerson Installing Your DeltaV Digital Automation System, D800001X152, March 2006; M-series I/O Subsystem Horizontal Carriers, January 2024.
FAQ View All FAQ
-
What can the two positions of KJ4001X1-BA2 VE3051C0 12P1562X042 accommodate?The BA2 carrier supports one system power supply with one controller, or two system power supplies. The supplied modules and accessories must be identified separately in the quotation.
-
Where does a simplex controller mount on KJ4001X1-BA2 VE3051C0 12P1562X042?The controller mounts in the right-hand position of the 2-wide power/controller carrier. Align its rear connectors and secure it using the original installation procedure.
-
How does KJ4001X1-BA2 VE3051C0 12P1562X042 connect to adjacent carriers?The BA2 arrangement joins adjacent carriers through 48-pin connectors on their sides. Establish correct alignment before fastening the carriers to the rail.
-
Which DIN rail profiles are used for the BA2 arrangement of KJ4001X1-BA2 VE3051C0 12P1562X042?The original BA2 installation arrangement supports standard 35 mm T- and G-type rails. A heavier 15 mm-deep T rail is recommended for the equipment weight distribution.
-
Where is KJ4001X1-BA2 VE3051C0 12P1562X042 positioned relative to the I/O carriers?The 2-wide power/controller carrier is installed to the left of any 8-wide I/O carriers in the horizontal arrangement.
-
Is KJ4001X1-BA2 VE3051C0 12P1562X042 itself a power-supply module?No. It mounts and interconnects the selected modules. The separate system power supply performs power conversion for the controller and I/O arrangement.
-
Can one KJ4001X1-BA2 VE3051C0 12P1562X042 carrier provide controller redundancy?A redundant controller requires an additional power/controller carrier. The complete arrangement also depends on the chosen controllers, supplies and system configuration.
-
What does VE3051C0 identify within KJ4001X1-BA2 VE3051C0 12P1562X042?VE3051C0 is the 2-wide power/controller carrier ordering reference. Retain KJ4001X1-BA2 and assembly reference 12P1562X042 when matching the offered item to the installed hardware.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.