The 330103-00-13-05-02-05 is a Bently Nevada 3300 XL 8 mm non-contacting eddy-current probe with an M10 x 1 threaded case, no armor, 0 mm unthreaded length, 130 mm overall case length, 0.5 m (1.6 ft) standard cable, a miniature ClickLoc connector without a protector, and the CSA, ATEX, and IECEx approvals option.
- 3300 XL 8 mm unarmored metric proximity probe
- M10 x 1
- None
- 0 mm
In a correctly matched 3300 XL 8 mm transducer system, it detects distance to a conductive shaft or target and supplies proportional static-position and dynamic-vibration signals to compatible machinery-protection and condition-monitoring channels. For dependable measurement, follow official system-matching, target, mounting, wiring, environmental, and approval instructions.
Important Notice: 330103 is the official metric M10 x 1 probe family without armor. Match the electrical system length and verify the 05 certification on the supplied nameplate.
Apter Power 330103-00-13-05-02-05 Manuals and Guides
Important Notice: These are two separate Apter Power documents prepared from the manufacturer-published 3300 XL 8 mm technical information. Confirm the physical nameplate, current manufacturer documents, and applicable certification before installation or replacement.
Fluid-Film-Bearing MachineryProvides shaft vibration and position measurements at M10 x 1 metric locations on rotating machinery.
Radial Shaft VibrationMeasures dynamic shaft motion relative to the probe mounting point.
Static Shaft PositionMeasures the static distance between the probe tip and a conductive shaft or target.
Axial or Thrust PositionSupports axial displacement measurement when the target and mounting geometry meet official requirements.
Keyphasor ReferenceSupports phase-reference measurement with the correct target geometry and monitoring input.
Speed MeasurementSupports rotational-speed measurement when the matched system and monitoring channel meet manufacturer requirements.
Read and follow Bently Nevada 3300 XL 8 mm Proximity Transducer System Datasheet 141194 Rev. AM and the applicable installation instructions before use. Verify the exact ordering code from the physical nameplate.
1Use a correctly configured 4.5 m 330130 extension cable with a 5.0 m 3300 xl proximitor sensor.
2Maintain the 25.4 mm minimum bend radius and protect the unarmored cable.
3Follow official M10 x 1 thread engagement and probe-case torque instructions.
4Gap the complete system against the intended target material before commissioning.
5Confirm the 05 approval nameplate, barriers, and applicable safe-use drawing before hazardous-area installation.