Match the complete marking
M10 x 1 reverse mounting, fixed 5 mm / 46 mm case geometry, a 1 m lead and miniature clickloc connector. Match the metric reverse-mount geometry, 1 m electrical lead, connector and complete 11 mm system calibration. Do not substitute an 8 mm system component.
-
Check the offered item before ordering
The listed item is the probe. A matching extension, 11 mm Proximitor and mounting hardware are required for the measurement system and are supplied only when itemized. Retain the current channel settings for verification.
Technical specifications for 330706-005-046-10-02-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:330706-005-046-10-02-00
-
Weight:0.05 kg
-
Tariff Code:8537101190
-
Sensing principle:Non-contact eddy current
-
Sensing tip:11 mm nominal, PPS
-
Case thread:M10 x 1, reverse mount
-
Unthreaded length:5 mm
-
Case length:46 mm
-
Integral lead length:1.0 m
-
Connector:Miniature ClickLoc coaxial
-
Cable impedance:75 ohms triaxial
-
Cable insulation:FEP
-
Probe resistance:5.9 ±0.5 ohms at 1 m
-
System scale factor:3.94 V/mm (100 mV/mil) nominal
-
System linear range:4 mm; 0.5 to 4.5 mm gap
-
Recommended nominal gap:2.5 mm
-
Compatible system lengths:5 m or 9 m with matching components
-
Probe temperature:-52 to +177 °C
-
Recommended case torque:7.5 N·m for reverse-mount probe
-
Maximum case torque:22.6 N·m
-
Minimum cable bend radius:25.4 mm
-
Minimum flat target diameter:30.5 mm
-
Minimum shaft diameter:152 mm for specified performance
Information
- Bently Nevada 330706-005-046-10-02-00 places an 11 mm sensing tip at the target through a metric reverse-mount arrangement. The probe, extension cable and Proximitor work together to measure static position and dynamic shaft vibration.
Electrical lead: 1.0 m with miniature ClickLoc connector
Matched-system output: 3.94 V/mm nominal scale factor
The 1.0 m FEP-insulated, 75-ohm triaxial lead terminates in a miniature ClickLoc connector. Its center-to-outer-conductor resistance is 5.9 ±0.5 ohms. A compatible 4 m or 8 m extension completes a 5 m or 9 m system; the probe, extension and 11 mm Proximitor must be selected as a matching electrical-length combination.
In the matched system, the nominal scale factor is 3.94 V/mm and the linear range is 4 mm, approximately 0.5 to 4.5 mm of target gap. The standard performance setup uses a 2.5 mm gap, AISI 4140 steel target, -24 V DC supply and 10 kΩ load at 0 to +45 °C. Target material and geometry therefore form part of the measurement conditions, rather than being independent of the probe selection.
330706-005-046-10-02-00 Official 11 mm System Datasheet Excerpt
Original system characteristics, reverse-mount ordering information and metric probe drawing. PDF · 9 pages.330706-005-046-10-02-00 Installation & Verification Guide
Metric reverse mounting, calibrated cable matching, target clearance, gap setting and response verification. PDF · 5 pages.
Application scope: The application descriptions concern a complete calibrated chain. Target material, shaft diameter, clearance and installation temperature all affect suitability.
Metric reverse-mount measurement points
Fit the M10 x 1 reverse case in a matching mechanical arrangement while retaining access to the connector.Shaft-relative vibration channels
Measure dynamic motion with a matched 11 mm transducer chain and an appropriate monitor input.Static shaft position measurement
Use the system DC gap response for position tracking within the qualified linear region.Longer-range proximity systems
Apply the 4 mm system range where target geometry and electrical-length matching support the required measurement.
Confirm M10 x 1 threads and the reverse case arrangement before fitting.
Do not cut, splice or sharply bend the integral calibrated lead.
Check the actual transfer curve around the 2.5 mm nominal gap.
Use the reverse-mount recommendation; do not apply case torque to the connector.
Provide suitable target area and separation to avoid disturbed probe response.
Verify DC position, dynamic response and monitor indication before releasing the machine.
Alternative Names
Technical notes
Configuration: M10 x 1 reverse mounting, fixed 5 mm / 46 mm case geometry, a 1 m lead and miniature clickloc connector.
Integration: The listed item is the probe. A matching extension, 11 mm Proximitor and mounting hardware are required for the measurement system and are supplied only when itemized.
Acceptance: Verify DC position, dynamic response and monitor indication before releasing the machine.
Technical reference: Bently Nevada 3300 XL 11 mm Proximity Transducer System, 146256 Rev. T.
FAQ View All FAQ
-
Which part of 330706-005-046-10-02-00 distinguishes it from an imperial reverse probe?The 330706 reverse-mount case uses an M10 x 1 metric thread and fixed 5 mm unthreaded / 46 mm case geometry. Do not install it into a 3/8-24 UNF mounting hole.
-
Which extension lengths pair with the 1 m lead of 330706-005-046-10-02-00?A matching 4 m extension makes a 5 m system, while a matching 8 m extension makes a 9 m system. Use the corresponding 3300 XL 11 mm Proximitor calibration.
-
Is the 3.94 V/mm output generated directly by 330706-005-046-10-02-00?No. That scale factor belongs to the complete probe, extension cable and Proximitor system. The probe must be connected to the matching conditioner.
-
Why does target material matter when setting 330706-005-046-10-02-00?The specified calibration uses AISI 4140 steel. Different conductivity or permeability can change the transfer curve, so verify the response against the actual target material.
-
What torque should be used on the reverse case of 330706-005-046-10-02-00?The recommended reverse-mount case torque is 7.5 N·m, with a maximum of 22.6 N·m. This is separate from the much lower connector tightening limit.
-
Can the lead of 330706-005-046-10-02-00 be shortened to remove slack?Keep the integral lead intact. Altering the cable changes the calibrated electrical system; route spare length without bending below the 25.4 mm minimum radius.
-
How should a small shaft be assessed for 330706-005-046-10-02-00?The specified system performance uses a minimum shaft diameter of 152 mm and a minimum flat target diameter of 30.5 mm. Smaller geometry requires application assessment and response verification.
-
Does the temperature limit of 330706-005-046-10-02-00 apply to its Proximitor?No. Probe and extension operation extends to +177 °C, while the Proximitor upper limit is +100 °C. Keep each component within its own temperature rating.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.