Match the complete marking
Include 3300/48-04-02-01-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 3300/48-04-02-01-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 3300/48-04-02-01-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300/48-04-02-01-00
-
Weight:1.08 kg
-
Tariff Code:8537101190
-
Monitor function:Two-channel casing expansion
-
Full-scale range:0–50 mm
-
Transducer input:2 in. DC LVDT; 10 mV/mil
-
Alarm relay option:Epoxy sealed
-
Agency approval option:00 — Not required
-
Signal input impedance:1.0 megohm
-
Nominal power consumption:1.5 W
-
Signal-conditioning accuracy:±0.33% FS typical; ±1% FS maximum at +25°C
-
Recorder formats:4–20 mA; 1–5 Vdc; 0 to -10 Vdc
-
Alarm measurement:Differential mode only
-
Operating temperature:0 to +65°C
-
Relative humidity:Up to 95%, noncondensing
Information
- Bently Nevada 3300/48-04-02-01-00 serves existing 3300 rack installations. A metric casing-expansion display combines the 50 mm scale with a two-inch DC LVDT input setting; those two choices must be preserved together.
Transducer match: 2 in. DC LVDT; 10 mV/mil
Relay configuration: Epoxy sealed
Alarm basis: Differential casing movement
Alert and Danger levels are adjustable over 0–100% of full-scale in Differential mode. Display and setting resolution is within ±1.6% of full-scale; alarm repeatability after adjustment is within ±0.4% of full-scale. Epoxy sealed is the ordered relay configuration. Delay, reset and energized-state settings remain separate commissioning choices that must match the rack alarm arrangement.
Recorder outputs can be configured for 4–20 mA, 1–5 Vdc or 0 to -10 Vdc, with two direct channels or one differential measurement. A current output supports 0–600 ohms; a voltage output requires at least 10 kilohms. Buffered transducer connections support signal inspection, while the LCD and OK indicators provide adjustment and diagnostic information.
-
Bently Nevada 3300/48-04-02-01-00 technical reference
Original manufacturer excerpt - PDF, 4 pages. Monitor option identification, reading setpoints, self-tests and diagnostic indications. -
Bently Nevada 3300/48-04-02-01-00 installation guide
Prepared by Apter Power - PDF, 5 pages. Configuration review, signal connections, alarm settings, commissioning and handover.
Integration boundary: Coordinate the machine mounting arrangement, recorder scaling and rack alarm logic. A matching family name alone does not establish an interchangeable range, input sensitivity or relay module.
-
Casing growth
Track movement of the casing relative to the machine foundation using two DC LVDTs. -
Unequal movement
Use the differential measurement to compare displacement at the two monitored locations. -
Rack alarm circuits
Integrate the epoxy sealed relay option with the intended Alert and Danger circuits. -
Trend recording
Scale the selected current or voltage recorder signal to the 0–50 mm monitor range.
Use 2 in. dc lvdt; 10 mv/mil inputs with the 0–50 mm scale.
Alert and Danger comparisons are available only in Differential mode.
The order specifies epoxy sealed; verify the actual rear module and downstream contact circuit.
Use 0–600 ohms for 4–20 mA or at least 10 kilohms for a voltage output.
Record delay, reset, energized state, recorder mode and upscale direction before replacement.
Resolve active error indications and verify both channels before returning the measurement to service.
Alternative Names
Technical notes
Measurement relationship: The LVDTs measure casing displacement relative to the foundation. This is not a rotor differential-expansion probe measurement.
Alarm configuration: Epoxy sealed is the ordered relay option. Alert and Danger comparisons operate only in Differential mode; verify relay wiring, reset behavior and delay before service.
Technical reference: Bently Nevada 3300/48 Specifications and Ordering Information, 141510-01 Rev. F; Case Expansion Monitor Operation, 84417-01 Rev. NC. The original operation excerpt covers option identification, setpoint reading and self-test indications.
FAQ View All FAQ
-
Which metric range is configured in 3300/48-04-02-01-00?Range option 04 selects 0–50 mm. Input option 02 matches a 2 in. DC LVDT with a 10 mV/mil sensitivity; the metric display range and transducer option are separately encoded.
-
How does 3300/48-04-02-01-00 use its two LVDT channels?The monitor can display two independent casing-expansion measurements or their difference. Differential mode supplies Alert and Danger alarm comparisons; Direct mode does not provide those alarms.
-
What relay construction is specified for 3300/48-04-02-01-00?Relay option 01 specifies epoxy-sealed alarm relays. The rear relay assembly and installed wiring must match the complete order code and intended Alert and Danger contact circuits.
-
How should a voltage recorder connected to 3300/48-04-02-01-00 be loaded?For 1–5 Vdc or 0 to -10 Vdc operation, the output impedance is 100 ohms and the load resistance must be at least 10 kilohms. Configure the receiving input and scaling to match the selected format.
-
What happens if a recorder output on 3300/48-04-02-01-00 is shorted?The monitor operation is unaffected by a short circuit on a recorder output. This does not make the recorder reading valid; correct the output wiring fault and prove the receiving signal before returning the measurement to service.
-
How can the upscale direction of 3300/48-04-02-01-00 be configured?A field-programmable option selects movement toward or away from the transducer as upscale. Confirm the LVDT mounting direction and both channel settings against the machine movement convention.
-
How is the LVDT supply protected in 3300/48-04-02-01-00?The transducer supply is -24 Vdc and is current-limited separately for each channel on the monitor circuit board. Preserve the specified DC LVDT wiring and do not interchange signal and power terminals.
-
What diagnostics does 3300/48-04-02-01-00 perform during operation?The monitor provides power-up, cyclic and user-invoked self-tests. A continuing error stops monitoring until the error is removed and produces an LCD error indication; retain the error record before following the applicable troubleshooting procedure.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-