Match the complete marking
Include 3300-35-03-02-02-01-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.
-
Check the offered item before ordering
Request available label and connector photos. Have your maintenance team compare the offered 3300-35-03-02-02-01-00 with the installed equipment and applicable Bently Nevada documentation.
Technical specifications for 3300-35-03-02-02-01-00
-
Manufacturer:Bently Nevada
-
Product Category:Machinery Monitoring Systems
-
Spare Part Number:3300-35-03-02-02-01-00
-
Weight:1.15 kg
-
Tariff Code:8537101190
-
Input channels:Up to six RTDs
-
Ordered range:03: 0–400°F
-
RTD input:02: Three-wire 100Ω platinum, α = 0.00385
-
Alarm relays:02: Hermetically sealed
-
Agency option:01: CSA/NRTL/C; supplied approval marking must match
-
Safety barriers:00: None
-
Nominal power:4 W
-
Recorder outputs:Per channel: selectable 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc
-
Display:Common four-digit LCD; 0.1 or 1 resolution selectable
-
Display accuracy:At +25°C: within 1°C with tenths digit; 1.5°C without
-
Rack requirement:Two monitor positions
-
Operating temperature:0°C to +65°C
Information
- Bently Nevada 3300-35-03-02-02-01-00 monitors up to six independent RTD temperature channels within a configured 3300 monitoring system.
Input selection: Three-wire 100Ω platinum, α = 0.00385
Ordered range: 0–400°F
The monitor accepts up to six independent RTD signals and has a nominal power consumption of 4 W. It provides an independent recorder output for each channel, selectable as 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc, proportional to the programmed full-scale range. At +25°C, display accuracy is within 1°C when the tenths digit is displayed and 1.5°C without the tenths digit; output accuracy has its own additional terms.
A common four-digit LCD supports channel scanning and highest-reading selection, while status indications identify OK, alarms and bypass conditions. Alarm 1 is an over-temperature alarm; Alarm 2 can be configured for over- or under-temperature operation. The monitor occupies two rack positions outside the power-supply and system-monitor locations. Verify sensor wiring, recorder scaling, relay configuration and calibration after changing the monitor or power supply.
-
Bently Nevada 3300-35-03-02-02-01-00 technical reference
Prepared by Apter Power - PDF, 5 pages, 96.4 KB. The 3300/35 ordering definition maps the offered 3300-35-03-02-02-01-00 to the stated RTD, range and relay selections. Field-programmable settings and approval applicability require verification on the supplied assembly. -
Bently Nevada 3300-35-03-02-02-01-00 installation planning guide
Prepared by Apter Power - PDF, 5 pages, 97.6 KB. Identity, configuration, connection and controlled acceptance planning.
Platform applications: The following applications describe 3300 temperature monitoring functions. Match the complete 3300-35-03-02-02-01-00 identity to the installed system before selecting a replacement.
-
Bearing temperature monitoring
Observe compatible three-wire platinum RTDs at bearing temperature points, with scaling and alarm limits selected for the machine. -
Multi-point temperature observation
Collect up to six independent RTD channels in a common monitor while retaining channel-specific status and recorder outputs. -
Recorder integration
Provide the selected analog recorder signal to a compatible receiving system and align full-scale scaling at both ends. -
Temperature alarm integration
Use the configured over-temperature and selectable over/under alarm functions with the intended relay and machine protection arrangement.
Use the selected three-wire 100Ω platinum characteristic, alpha 0.00385, and verify lead connections.
Check 0–400°F ordering identity against the actual configured scale and display units.
Match the hermetic relay selection and the installed alarm logic to the machine protection design.
Select the proper current or voltage mode and confirm compatible receiver loading and scaling.
Verify the actual CSA/NRTL/C marking and installation conditions; no safety barriers are selected in this model.
Check channel indication, alarm behavior, bypass removal and recorder response under a controlled acceptance procedure.
Alternative Names
Technical notes
Installation relationship: The monitor accepts up to six independent RTD signals and has a nominal power consumption of 4 W. It provides an independent recorder output for each channel, selectable as 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc, proportional to the programmed full-scale range. At +25°C, display accuracy is within 1°C when the tenths digit is displayed and 1.5°C without the tenths digit; output accuracy has its own additional terms.
Configuration: The 3300/35 ordering definition maps the offered 3300-35-03-02-02-01-00 to the stated RTD, range and relay selections. Field-programmable settings and approval applicability require verification on the supplied assembly.
Technical reference: Bently Nevada 3300/30 and 3300/35 Six-Channel Temperature Monitors, 141503-01 Rev. H.
FAQ View All FAQ
-
Which RTD input is selected for 3300-35-03-02-02-01-00?Input option 02 specifies three-wire 100Ω platinum RTDs with alpha 0.00385. Match the sensor resistance characteristic and wire arrangement.
-
What temperature range is ordered for 3300-35-03-02-02-01-00?Range option 03 is 0–400°F. Confirm the installed scaling and calibration because field-programmable settings can be changed.
-
How many temperature channels can 3300-35-03-02-02-01-00 monitor?The 3300/35 design accepts up to six RTD signals and monitors them as independent temperature channels.
-
Which recorder signals can 3300-35-03-02-02-01-00 provide?Each channel has a selectable 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc output proportional to the configured full-scale range. Match the receiving system and output setting.
-
How are the two alarms used on 3300-35-03-02-02-01-00?Alarm 1 is an over-alarm. Alarm 2 can be programmed as an over- or under-alarm. Setpoints and relay behavior must match the machine protection design.
-
How much rack space does 3300-35-03-02-02-01-00 require?It occupies two rack positions. Do not use the reserved power-supply and system-monitor positions.
-
Does 3300-35-03-02-02-01-00 include safety barriers?The final 00 selects no safety barriers. The 01 agency selection does not by itself provide an intrinsically safe sensor circuit.
-
When should calibration be checked for 3300-35-03-02-02-01-00?Check and recalibrate as needed when a spare monitor or power supply is installed. Recheck the selected RTD type, programmed range and recorder scaling before service.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.