Product Describe:

Bently Nevada 3300-35-03-02-02-01-00 is a six-channel RTD temperature monitor configured for 0–400°F, three-wire 100Ω platinum inputs and hermetically sealed relays.
  • Manufacturer part number
    3300-35-03-02-02-01-00
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    5cm x 32cm x 20.5cm
  • Country of Origin
    USA
Get a quick price for 3300-35-03-02-02-01-00
E-mail *
Mobile *
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the full 3300-35-03-02-02-01-00 marking and installed 3300 temperature monitoring configuration.
  • 1

    Confirm the offer

    Review the exact assembly, condition, included items and quoted dispatch date.
  • 2

    Arrange dispatch

    Confirm delivery details for 3300-35-03-02-02-01-00; tracking follows when shipment is arranged.
  • Match the complete marking

    Include 3300-35-03-02-02-01-00 and any revision or assembly number visible on the item. Keep the exact reference on your enquiry and quotation.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered 3300-35-03-02-02-01-00 with the installed equipment and applicable Bently Nevada documentation.

Technical specifications for 3300-35-03-02-02-01-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    Machinery Monitoring Systems
  • Spare Part Number:
    3300-35-03-02-02-01-00
  • Weight:
    1.15 kg
  • Tariff Code:
    8537101190
  • Input channels:
    Up to six RTDs
  • Ordered range:
    03: 0–400°F
  • RTD input:
    02: Three-wire 100Ω platinum, α = 0.00385
  • Alarm relays:
    02: Hermetically sealed
  • Agency option:
    01: CSA/NRTL/C; supplied approval marking must match
  • Safety barriers:
    00: None
  • Nominal power:
    4 W
  • Recorder outputs:
    Per channel: selectable 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc
  • Display:
    Common four-digit LCD; 0.1 or 1 resolution selectable
  • Display accuracy:
    At +25°C: within 1°C with tenths digit; 1.5°C without
  • Rack requirement:
    Two monitor positions
  • Operating temperature:
    0°C to +65°C

Information

Overview Downloads Applications / Compatibility Product Precautions
  • Bently Nevada 3300-35-03-02-02-01-00 monitors up to six independent RTD temperature channels within a configured 3300 monitoring system.
Product type: Six-channel RTD temperature monitor
Input selection: Three-wire 100Ω platinum, α = 0.00385
Ordered range: 0–400°F
Bently Nevada 3300-35-03-02-02-01-00 uses the 3300/35 RTD input design. Range option 03 selects 0–400°F and input option 02 selects three-wire 100Ω platinum RTDs with an alpha of 0.00385. The relay selection is hermetically sealed, the agency option is CSA/NRTL/C, and the safety-barrier option is none. Confirm the supplied assembly and approval marking before relying on those selections in an installation.

The monitor accepts up to six independent RTD signals and has a nominal power consumption of 4 W. It provides an independent recorder output for each channel, selectable as 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc, proportional to the programmed full-scale range. At +25°C, display accuracy is within 1°C when the tenths digit is displayed and 1.5°C without the tenths digit; output accuracy has its own additional terms.

A common four-digit LCD supports channel scanning and highest-reading selection, while status indications identify OK, alarms and bypass conditions. Alarm 1 is an over-temperature alarm; Alarm 2 can be configured for over- or under-temperature operation. The monitor occupies two rack positions outside the power-supply and system-monitor locations. Verify sensor wiring, recorder scaling, relay configuration and calibration after changing the monitor or power supply.
Controller platform reference: 3300 temperature monitoring. Match the installed configuration before replacement.
Technical downloads for 3300-35-03-02-02-01-00: an Apter Power technical reference summary and an Apter Power installation planning guide.
The 3300/35 ordering definition maps the offered 3300-35-03-02-02-01-00 to the stated RTD, range and relay selections. Field-programmable settings and approval applicability require verification on the supplied assembly. The planning guide is prepared by Apter Power; apply the complete manufacturer instructions and the stated applicability boundaries.
System and supply context: The 3300/35 ordering definition maps the offered 3300-35-03-02-02-01-00 to the stated RTD, range and relay selections. Field-programmable settings and approval applicability require verification on the supplied assembly. Accessories are included only when itemized in the quotation.

Platform applications: The following applications describe 3300 temperature monitoring functions. Match the complete 3300-35-03-02-02-01-00 identity to the installed system before selecting a replacement.
Prepare 3300-35-03-02-02-01-00 against the installed configuration and applicable Bently Nevada instructions. Plan isolation and the resulting interruption of system operation before replacement.
Match RTD characteristics

Use the selected three-wire 100Ω platinum characteristic, alpha 0.00385, and verify lead connections.

Confirm range and units

Check 0–400°F ordering identity against the actual configured scale and display units.

Verify relay hardware

Match the hermetic relay selection and the installed alarm logic to the machine protection design.

Check recorder loading

Select the proper current or voltage mode and confirm compatible receiver loading and scaling.

Preserve approval boundaries

Verify the actual CSA/NRTL/C marking and installation conditions; no safety barriers are selected in this model.

Test before service

Check channel indication, alarm behavior, bypass removal and recorder response under a controlled acceptance procedure.

Alternative Names

Bently Nevada 3300-35-03-02-02-01-00 Bently Nevada 3300/35-03-02-02-01-00

Technical notes

Installation relationship: The monitor accepts up to six independent RTD signals and has a nominal power consumption of 4 W. It provides an independent recorder output for each channel, selectable as 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc, proportional to the programmed full-scale range. At +25°C, display accuracy is within 1°C when the tenths digit is displayed and 1.5°C without the tenths digit; output accuracy has its own additional terms.

Configuration: The 3300/35 ordering definition maps the offered 3300-35-03-02-02-01-00 to the stated RTD, range and relay selections. Field-programmable settings and approval applicability require verification on the supplied assembly.

Technical reference: Bently Nevada 3300/30 and 3300/35 Six-Channel Temperature Monitors, 141503-01 Rev. H.

FAQ View All FAQ

  • Which RTD input is selected for 3300-35-03-02-02-01-00?
    Input option 02 specifies three-wire 100Ω platinum RTDs with alpha 0.00385. Match the sensor resistance characteristic and wire arrangement.
  • What temperature range is ordered for 3300-35-03-02-02-01-00?
    Range option 03 is 0–400°F. Confirm the installed scaling and calibration because field-programmable settings can be changed.
  • How many temperature channels can 3300-35-03-02-02-01-00 monitor?
    The 3300/35 design accepts up to six RTD signals and monitors them as independent temperature channels.
  • Which recorder signals can 3300-35-03-02-02-01-00 provide?
    Each channel has a selectable 4–20 mA, +1 to +5 Vdc or 0 to −10 Vdc output proportional to the configured full-scale range. Match the receiving system and output setting.
  • How are the two alarms used on 3300-35-03-02-02-01-00?
    Alarm 1 is an over-alarm. Alarm 2 can be programmed as an over- or under-alarm. Setpoints and relay behavior must match the machine protection design.
  • How much rack space does 3300-35-03-02-02-01-00 require?
    It occupies two rack positions. Do not use the reserved power-supply and system-monitor positions.
  • Does 3300-35-03-02-02-01-00 include safety barriers?
    The final 00 selects no safety barriers. The 01 agency selection does not by itself provide an intrinsically safe sensor circuit.
  • When should calibration be checked for 3300-35-03-02-02-01-00?
    Check and recalibrate as needed when a spare monitor or power supply is installed. Recheck the selected RTD type, programmed range and recorder scaling before service.
Related reading

Related cases and sourcing guidance

View all case studies
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313

    Speak to our team in your native language.