Technical specifications for 1756-L61S
-
Manufacturer:Allen-Bradley
-
Product Category:PLC Systems
-
Spare Part Number:1756-L61S
-
Estimated shipping dimensions:3.5x14x14.5cm
-
Weight:0.38 kg
-
Tariff Code:8537101190
-
Counliy of origin:USA
-
Standard memory:2 MB
-
Safety memory:1 MB
-
Required safety partner:1756-LSP
-
Maximum controller connections:250
-
Built-in communication port:RS-232 serial
-
Backplane current at 5.1 V DC:1.2 A
-
Backplane current at 24 V DC:14 mA
-
Power dissipation:3.5 W
-
Thermal dissipation:11.9 BTU/h
-
Battery:1756-BA2
-
Operating temperature:0-60 C
-
Storage temperature:-40-85 C
-
Relative humidity:5-95%, noncondensing
Information
- Maintains the coordinated standard and safety task architecture
- Creates the safety partnership across adjacent chassis slots
- Controls safety I/O through the validated GuardLogix project
- Provides controller and safety-partner status for commissioning
1756-L61S operates with 1756-LSP safety partner, 1756 ControlLogix chassis, Guard I/O or safety I/O network, validated GuardLogix application.
Typical engineered duties include 1756-L61S safety-controller replacement, Machine emergency-stop logic, Guarding and access-control functions, Safety I/O validation and proof testing.
Important Notice: Do not return 1756-L61S to safety service until controller/partner placement, firmware, safety signature, I/O ownership and the validated safety test all agree with the approved machine record.
Apter Power 1756-L61S Manuals and Guides
- Apter Power 1756-L61S Product Reference Manual
- Rockwell Automation Official Installation or User Manual
Important Notice: The first document is an Apter Power 1756-L61S model-specific technical reference. The second is a distinct document for installation, configuration or system engineering.
Technical notes
FAQ View All FAQ
-
Where must the 1756-LSP be installed for 1756-L61S?Place the safety partner in the slot immediately to the right of the primary controller in the same 1756 chassis.
-
Which firmware check is mandatory for 1756-L61S?The primary controller and 1756-LSP must use matching major and minor firmware revisions supported by the validated project.
-
How is the safety project protected on 1756-L61S?Use the approved safety locking and signature process, then record the signature with the validated application.
-
What must be backed up before replacing 1756-L61S?Archive the complete GuardLogix project, firmware, safety signature, controller properties, I/O tree and validation record.
-
Can 1756-L61S run safety without a 1756-LSP?No. The GuardLogix 5560 safety architecture requires the paired 1756-LSP safety partner.
-
How should safety I/O be checked after fitting 1756-L61S?Confirm ownership and connection status, then execute the approved proof test for every affected input, output and safety function.
-
What diagnostics must be clear before placing 1756-L61S in Run?Resolve primary-controller, safety-partner, safety-task, signature and safety-I/O faults before enabling operation.
-
Can another GuardLogix controller replace 1756-L61S without revalidation?No. Any catalog, firmware, project or safety-signature change requires the site-defined migration and validation process.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-