ABB RB4C-355/170 is an evidence-bounded ACS880 IP54 cabinet cooling fan. ABB's current product record and ACS880 hardware manuals map RB4C-355/170 exactly to ordering code 3AXD50000006934 as an IEC 230 V, 50/60 Hz cabinet cooling fan.
- Exact model: RB4C-355/170
- ABB ordering code: 3AXD50000006934
- Component role: IEC cabinet cooling fan
- Documented auxiliary supply: 230 V, 50/60 Hz
System role: It provides forced-air cooling in the documented ACS880 IP54 cabinet arrangements; the required quantity depends on cabinet width and drive package. Only facts stated by the cited ABB material are published; sibling, successor and third-party data are not transferred. Architecture boundary: For the cited IEC ACS880 arrangements, one fan is specified for a 400 mm IP54 cabinet and two for an 800 mm IP54 cabinet; the associated capacitor and connectors are separately ordered parts. Do not substitute the 115 V UL/CSA fan or the distinct 600 mm cabinet fan, and do not infer compatibility outside the exact ACS880 cabinet drawing, auxiliary voltage and protection-class table. Before installation or replacement, verify the complete physical label, host equipment, companion hardware, wiring and approved commissioning procedure. Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.
Important Notice: Verify the complete ABB RB4C-355/170 physical label and installed-system documentation before use.
Apter Power RB4C-355/170 3AXD50000006934 Manuals and Guides
Important Notice: The first link is the model-specific product-parameters PDF prepared only from the cited ABB official evidence; the second link is the Apter Power product information manual. Confirm the physical nameplate, current ABB documents, and host-system requirements before installation or replacement.
Installed-base maintenanceSupports evidence-led identification and replacement planning for ABB RB4C-355/170.
System documentationProvides a source-traceable boundary for the documented ABB ACS880 cabinet cooling architecture configuration.
Commissioning reviewGuides identity, companion-hardware, wiring and controlled functional checks before return to service.
Migration assessmentSeparates exact-model facts from successor, sibling and family-level information.
Read and follow the exact ABB documentation and host-equipment instructions before work. Verify the complete physical nameplate and system configuration.
1Verify the complete ABB RB4C-355/170 label, revision and installed-system documentation before use.
2Do not substitute the 115 V UL/CSA fan or the distinct 600 mm cabinet fan, and do not infer compatibility outside the exact ACS880 cabinet drawing, auxiliary voltage and protection-class table.
3De-energize the equipment and follow the site's approved electrical and process-safety procedure before disturbing hardware or wiring.
4Back up controller, drive, network and configuration data before replacement, migration or firmware work.
5Verify every companion module, cable, connector, termination and power source from approved drawings.
6Do not copy electrical, communication, mechanical or lifecycle values from a related model or successor.
7Perform a documented functional test and confirm diagnostics, alarms and fail-state behavior after work.
8Origin and HS code remain unpublished unless an exact manufacturer record or the physical package label establishes them.