Its documented system role is to provide the termination/interface point used with the SPHSS13 hydraulic servo module and NKHS03 cable so the controller-side module can be connected to the engineered turbine valve-position field circuit; the exact terminal allocation and internal circuitry must come from the ABB NTHS03 instruction and project drawing. The associated SPHSS13 hydraulic-servo system conditions LVDT actuator-position feedback, drives redundant servo-valve coils or an I/H converter, and provides feedback/demand test outputs plus raise, lower, and trip-bias contact inputs. Public ABB sources cited here do not specify which NTHS03 terminals carry each signal, their ratings, or whether every system signal is present in every configuration, so no terminal-level value may be guessed. Use NTHS03 only with the documented SPHSS13/legacy HSS host arrangement, NKHS03 cable, the correct LVDT, servo valve or I/H converter, controller and firmware, cabinet power and grounding, and ABB turbine-control drawings in steam-turbine throttle/control valves, gas-turbine fuel valves, inlet-guide-vane or nozzle-angle positioning, and related industrial power-generation applications.
Apter Power NTHS03 Manuals and Guides
Important Notice: The first link is the product-parameters PDF prepared only from the cited manufacturer information; the second link is the Apter Power product manual. Confirm the physical nameplate, current manufacturer documents, and host-system requirements before installation or replacement.