Technical specifications for 3BHE014557R0003 UN1000B-Z,V3
-
Manufacturer:ABB
-
Product Category:General Automation
-
Spare Part Number:3BHE014557R0003 UN1000B-Z,V3
-
Weight:4.3 kg
-
Tariff Code:8537101190
-
Product type:Voltage Regulator
-
Reference platform:UNITROL 1000-15
-
Machine application:Synchronous generators and synchronous motors
-
Power-stage principle:Microprocessor-controlled IGBT excitation stage
-
Supply architecture:Separate auxiliary and excitation-power circuits
-
Measurement functions:Machine voltage and machine current
-
Commissioning interface:RS-232 connection for CMT 1000
-
Load-sharing interface:RS-485
-
Expansion interface:CAN bus
Information
- ABB 3BHE014557R0003 UN1000B-Z,V3 is offered for UNITROL excitation-control maintenance in an installed synchronous-generator or synchronous-motor system.
Platform: UNITROL 1000-15 excitation control
Selection basis: Complete unit marking, control software and installed options
At platform level, automatic voltage, power-factor and reactive-power regulation use PID control, while manual excitation-current regulation uses PI control. Reactive-current droop supports operation in parallel with a network; voltage droop compensation uses communication between regulators for reactive-load sharing in island operation. Soft start and bumpless transfers form part of the base control concept. Enabled modes, machine settings and limiter behavior must match the installed software and excitation design.
The base architecture provides RS-232 communication for the CMT 1000 commissioning tool, RS-485 for reactive-load sharing and CAN communication for local expansion. Digital and analogue interfaces connect external commands, measurements and status signals. Automatic synchronizing and rotating-diode monitoring are separately configured functions; they must not be inferred from the voltage-regulator role or treated as included accessories. Preserve the installed parameter set and confirm the actual V3 interfaces before replacement.
-
ABB 3BHE014557R0003 UN1000B-Z,V3 technical reference
Prepared by Apter Power - PDF, 5 pages, 25.5 KB. Technical summary of verified UNITROL 1000-15 design functions and applicable configuration boundaries. -
ABB 3BHE014557R0003 UN1000B-Z,V3 installation planning guide
Prepared by Apter Power - PDF, 5 pages, 25.5 KB. Installation planning, system integration and controlled acceptance checks.
Platform applications: The following applications describe UNITROL 1000-15 functions. Match the complete 3BHE014557R0003 UN1000B-Z,V3 identity to the installed system before selecting a replacement.
-
Generator excitation control
The UNITROL 1000-15 platform adjusts excitation for synchronous-generator voltage control. Match the machine measurements, exciter and active parameter set to the installed unit. -
Synchronous-motor excitation
Excitation control also applies to synchronous motors. Select the required operating mode and machine settings within the approved motor and excitation-system design. -
Parallel-machine operation
Reactive-current droop and platform load-sharing functions support coordinated operation. Apply the installed communication arrangement and control-software configuration. -
Commissioning and maintenance
CMT 1000 provides the platform commissioning interface. Preserve the existing parameter set and match the installed software before replacing or adjusting a regulator.
Keep 3BHE014557R0003 UN1000B-Z,V3, the actual serial label and control-software identity together. A similar UNITROL family name does not establish version equivalence.
Identify auxiliary electronics supply and excitation-stage supply in the machine wiring. Apply the ratings printed on the actual unit and its applicable original instructions.
Confirm voltage and current measurement connections against the installed excitation drawing. Correct signal scaling and polarity are part of the complete machine configuration.
Voltage, power-factor, reactive-power and manual-current control have different purposes. Use the approved machine procedure and installed parameter set when changing operating mode.
Check synchronizing, rotating-diode monitoring and expansion functions against the actual configuration. Platform optional functions do not establish what is included in the offered unit.
Qualified personnel must isolate the excitation system and manage stored energy before service. Restore operation under the applicable ABB instructions and approved machine commissioning procedure.
Alternative Names
Technical notes
Installation relationship: At platform level, automatic voltage, power-factor and reactive-power regulation use PID control, while manual excitation-current regulation uses PI control. Reactive-current droop supports operation in parallel with a network; voltage droop compensation uses communication between regulators for reactive-load sharing in island operation. Soft start and bumpless transfers form part of the base control concept. Enabled modes, machine settings and limiter behavior must match the installed software and excitation design.
Configuration: UNITROL 1000-15 base-design functions are described separately from the supplied V3 marking. Match hardware, control software and enabled options to the installed machine.
Technical reference: ABB UNITROL 1000-15 / UNITROL 1000-40 technical presentation, 11 December 2008.
FAQ View All FAQ
-
What role does 3BHE014557R0003 UN1000B-Z,V3 perform in an excitation system?It is offered as a voltage regulator for synchronous-machine excitation control. The full 3BHE014557R0003 UN1000B-Z,V3 marking identifies the item; the installed hardware and control software determine the applicable configuration.
-
How does the base excitation architecture of 3BHE014557R0003 UN1000B-Z,V3 operate?The UNITROL 1000-15 design combines microprocessor control with an IGBT excitation stage. Machine measurements feed the controller, which adjusts the exciter field output.
-
Are the auxiliary and excitation supplies for 3BHE014557R0003 UN1000B-Z,V3 the same circuit?They serve separate functions in the base design. Auxiliary power supports the electronics; the power-electronics input supplies the excitation output stage. Use the actual unit ratings and machine wiring.
-
Which automatic control modes belong to the base platform of 3BHE014557R0003 UN1000B-Z,V3?The base platform provides voltage, power-factor and reactive-power regulation using PID control. Apply only the modes enabled and commissioned for the installed unit and machine.
-
How does manual-current control differ from automatic voltage regulation in the base design of 3BHE014557R0003 UN1000B-Z,V3?The base design uses a PI excitation-current controller for manual regulation. Its purpose differs from automatic machine-voltage regulation, so a transfer must follow the installed excitation procedure.
-
What is the purpose of RS-232 in the base design of 3BHE014557R0003 UN1000B-Z,V3?It provides a connection for CMT 1000 commissioning and maintenance. Match the tool and control-software versions before transferring or modifying the installed parameter set.
-
What functions do RS-485 and CAN serve in the base architecture of 3BHE014557R0003 UN1000B-Z,V3?RS-485 supports reactive-load sharing between regulators. CAN supports local expansion. The actual installed wiring and enabled functions must correspond to the supplied hardware.
-
Does 3BHE014557R0003 UN1000B-Z,V3 include automatic synchronizing as standard?Automatic synchronizing and rotating-diode monitoring are separate platform options. Their presence and any supplied accessories must be confirmed for the actual unit and quotation.
Supporting new and legacy automation
-
Please try to be as accurate as possible with your search.
-
We can quote you on 1000s of specialist parts, even if they are not listed on our website.
-
We can't find any results for “”.
You May Also Like
Product Browsing History
-
Whatsapp: +86 18030235313
Send us a message. -
sales13@apterpower.com
Complete our online form. -
+86 18030235313
Speak to our team in your native language.