Speak to a sourcing specialist
sales13@apterpower.com

CDP312R

Drive Control Panel
ABB CDP312R drive control panel, front view with LCD display and keypad
ABB CDP312R drive control panel, rear view with RJ45 socket and label
ABB CDP312R drive control panel, angled rear view of nameplate label
ABB CDP312R drive control panel, front view with LCD display and keypad
ABB CDP312R drive control panel, rear view with RJ45 socket and label
ABB CDP312R drive control panel, angled rear view of nameplate label
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

ABB CDP312R is a local operating and parameter interface for compatible ACS800 drives. Its character display provides actual values, fault information and access to drive settings.
  • Manufacturer part number
    CDP312R
  • Shipping
    Swift global dispatch
  • Condition
    New, original product
  • Shipping size (est.)
    7.8cm x 2cm x 17cm
  • Country of Origin
    Sweden
Get a quick price for CDP312R
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 0

    Review your reference

    Send the complete CDP312R reference, label photos and required quantity. Confirm the CDP312R panel marking, keys, display and drive connection.

  • 1

    Confirm the offer

    Review the offered execution, condition and included items for CDP312R. Confirm the control panel and any mounting kit or connecting cable specifically itemized in the quotation.

  • 2

    Arrange dispatch

    Swift global dispatch. Confirm quantity, dispatch date and delivery details for CDP312R in the quotation.

  • Match the complete marking

    Match the complete ABB CDP312R marking and installed configuration. Confirm the CDP312R panel marking, keys, display and drive connection.

  • Check the offered item before ordering

    Request available label and connector photos. Have your maintenance team compare the offered CDP312R with the installed equipment and applicable ABB documents.

Technical specifications for CDP312R

  • Manufacturer:
    ABB
  • Product Category:
    General Automation
  • Spare Part Number:
    CDP312R
  • Weight:
    0.16 kg
  • Tariff Code:
    8537101190
  • Display:
    LCD, 4 lines × 20 characters
  • Actual signals displayed:
    3 simultaneously
  • Operating modes:
    ACT, PAR, FUNC, DRIVE
  • Control keys:
    7 drive-control functions
  • Idle display return:
    Actual-signal mode after 1 minute
  • Default drive ID:
    1
  • Default download groups:
    1–97
  • Excluded by default:
    Groups 98/99 and motor-identification results

Information

Overview Downloads Applications / Compatibility Product Precautions
  • ABB CDP312R places drive status, parameter editing and controlled parameter transfer at the maintenance interface. Its operating mode determines how the arrow and ENTER keys act, while local or remote selection determines command authority.
Operator workflow: Actual values, parameters, functions and drive selection
Status context: Drive identity, reference, direction and run state
Service functions: Parameter transfer and fault-history access
The display separates a drive-status row from the selected actual values or parameter information. This lets an operator interpret a value together with the active drive identity and control state rather than treating an isolated number as confirmation of the process condition.

Parameter editing and data transfer use different panel modes. A parameter upload retains drive values in the panel; a subsequent download must be matched to the destination firmware and motor application. Standard download handling excludes motor-identification results and the motor/option groups that require separate attention.

On a panel link with multiple drives, every station needs a distinct ID. Before issuing a start, stop, reference or reset command, confirm the selected drive and control authority. Return the drive to its required external-control state before removing the panel from a service position.
Controller platform reference: ACS800 drive control. Follow the applicable installation instructions and approved design.
Technical and service documents for ABB CDP312R, separating original engineering information from the installation and verification workflow.
Original manufacturer pages retain their technical context. Use the Apter Power guide with the applicable manufacturer instructions and approved installation design.
System and supply context: ABB CDP312R integrates with ACS800 drive control. Select companion hardware and configured functions for the actual installed arrangement.

Application scope: The applications describe the complete signal or control path. Confirm the intended function and interface; accessories are supplied only when itemized.
Prepare ABB CDP312R for its configured installation using these checks.
Identify the selected drive

Read the drive ID, control-state indicator and run state before making changes. Record the firmware/application identity and establish the approved machine maintenance state. On a panel link, confirm that the station address belongs to the intended drive.

Preserve the current settings

Capture the source configuration before editing or copying. Keep motor data and option-module settings separately because they are not covered by a normal groups 1–97 download. Label the backup with the installed drive identity.

Transfer only compatible parameters

Stop the destination drive and confirm matching firmware/application before downloading. Review motor and option setup separately and avoid copying a start-up state from an unrelated machine. Use the panel function indications to follow the selected transfer direction.

Review fault and actual-value behavior

Use the actual-value display to compare the chosen signals with the machine state. Inspect fault history before clearing it and resolve active warnings or faults. Check that a reset does not conceal a recurring condition.

Restore the control handover

Check the required external reference and start/stop source. Return the panel to the intended remote state before removal and confirm normal supervisory control. Keep the accepted parameter record with the service handover.

Configuration handover

Retain the final tested settings, physical connection and accepted process response for CDP312R.

Alternative Names

ABB CDP312R

Technical notes

Command authority: Panel navigation does not change the responsibility for local and external control. Confirm the selected drive and control state before issuing commands.

Parameter-copy boundary: Keep a verified parameter backup and separate motor-identification and option configuration from the normal download scope.

Fault interpretation: Retain fault history before reset. Compare displayed faults with the drive state and the actual machine condition.

FAQ View All FAQ

  • Why can an assistant be unavailable on CDP312R?
    Check whether scalar motor control, parameter lock or disabled assistant selection is active. These conditions can prevent the Start-up Assistant from being offered.
  • What does a download from CDP312R leave outside its normal transfer scope?
    Motor identification results and parameter groups 98 and 99 are excluded by default. Treat motor and option configuration as a separate commissioning responsibility.
  • Why should an upload precede copying parameters with CDP312R?
    An upload captures the intended source settings. Downloading from an unverified panel memory can transfer settings from a different drive application.
  • How does CDP312R prevent confusion between linked drives?
    The status and DRIVE modes identify the selected station. Each online drive needs a unique ID, which must be confirmed before control or parameter actions.
  • Why might fault history refuse to clear on CDP312R?
    Active faults or warnings prevent fault-history reset. Resolve the active condition and preserve useful diagnostic information before clearing the record.
  • Which state should be restored before removing CDP312R from a drive?
    Return the drive to the required remote or external operating state. Removing a panel while relying on local control can interrupt the intended control arrangement.
  • Can a matching panel prove that two drives accept the same parameter copy from CDP312R?
    No. Verify destination firmware, application program, motor data and option configuration before transferring settings.
  • How should a changed value on CDP312R be verified after editing?
    Confirm the accepted parameter value, the intended drive identity and its effect on actual operation. A displayed edit alone is not proof of the complete control response.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.
  • sales13@apterpower.com

    Complete our online form.
  • +86 18030235313