Speak to a sourcing specialist
sales13@apterpower.com

1SFB536068D1011

Low Voltage Module
In Stock
Fast Shipping Available
ABB 1SFB536068D1011
ABB 1SFB536068D1011
ABB 1SFB536068D1011
ABB 1SFB536068D1011
ABB 1SFB536068D1011
ABB 1SFB536068D1011
Product image is representative; revision or series may vary. Contact us to request a specific version.

Product Describe:

SoftStart PST/PSTB Low Voltage Module
ABB PST105/PSTB105 soft starter
board (75kW) featuring microsecond
five-fold fault protection and auto-logging
Get a quick price for 1SFB536068D1011
E-mail *
Mobile
Company
Content *
Quantity *
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy

What happens after you enquire

  • 1

    Requirement review

    We review the part number, quantity and delivery requirements and ask for any missing details.
  • 2

    Quotation and availability

    We confirm the proposed item, condition, availability, price and estimated lead time in the quotation.
  • 3

    Order confirmation and dispatch

    Once the quotation and purchasing details are agreed, your contact will coordinate the order and available dispatch information.

Technical specifications for 1SFB536068D1011

  • Manufacturer:
    ABB
  • Product Category:
    DCS Systems
  • Spare Part Number:
    1SFB536068D1011
  • Estimated shipping dimensions:
    21x15.2x3.5cm
  • Weight:
    0.34 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    SWEDEN
  • Application Voltage:
    Three-phase 380–500V
  • Power supply voltage:
    24V DC
  • Supported Motor Power:
    Up to 75 kW
  • Compatible Rated Current:
    105 A
  • Maximum Supported Motor Power:
    75 kW
  • Applicable Phases & Voltage:
    Three-phase 380-500V AC
  • Quantity Required Per Starter:
    1 piece

Information

Overview Manuals Common Applications Product Precautions
The 1SFB536068D1011 is the main control board in ABB's PST/PSTB series soft starters, with the specific hardware designation of PSPCB-LV/T terminal control board. This hardware component resides permanently within the fixed slots of the soft starter enclosure, serving as the core control unit connected directly to the control loop of the AC asynchronous motor.
    • MCU enables real-time V/I/F tracking, eliminating analog delays
    • Controlled voltage ramp-up regulates thyristors, preventing grid voltage dips
    • Microsecond loop disconnection and autonomous event logging upon faults
The 1SFB536068D1011 control motherboard establishes multiple protection mechanisms through its internal hardwired logic circuits and monitoring parameters. Beyond standard motor control operation, this hardware executes automatic fault detection, encompassing overload protection, short-circuit protection, over-temperature protection, over-voltage protection, and under-voltage protection.

The internal measurement circuitry of the control board stays constantly active, continuously extracting health indicators and physical data from both the motor and the external supply lines. Once the circuitry captures motor operational parameters shifting outside the preconfigured voltage ranges or specific tolerance levels, the control board automatically triggers the corresponding protective action response, cutting off the abnormal loop and logging these physical anomaly events into the system status log in real time.

Compared to previous older control structures of a similar nature, this motherboard specification integrates more comprehensive protection capabilities within the original PST/PSTB platform infrastructure, while reducing the physical hardware volume.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ABB 1SFB536068D1011 Low Voltage Module Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in t330101-00-16-10-01-05n.
Metallurgy & Steel Industry
Applied in the startup control of blast furnace charging belt conveyors and auxiliary motors for blast furnace blowers to reduce instantaneous stress on drive bearings.

Oil & Gas Industry
Deployed within the power circuits of water injection pumps, submersible oil pumps, and crude oil long-distance pipeline booster pumps to counteract water hammer effects and current surges during startup.

Chemical & Petrochemical Industry
Delivers controlled voltage ramp-up starting for reactor agitators, cooling tower fans, and small-to-medium centrifugal compressor motors to avoid abrupt torque losses.

Water Treatment & Municipal Environmental Industry
Utilized in power supply systems for municipal sewage pumps, deep-well submersible pumps, and aeration blowers, leveraging the microprocessor to monitor motor startup parameters and execute overload protection.

Thermal Power
Applied to the digital control of coal feeders, mortar pumps, and circulating water pump motors within plant electrical loops to prevent system voltage dips triggered by starting.

Paper & Pulp Industry
Used for the smooth acceleration of pulper drive gearbox motors and high-speed rewinder conveyance-stage motors, eliminating belt and gear mechanical wear caused by direct-on-line starting.
 During installation, the motherboard must be precisely seated within the fixed slots inside the soft starter enclosure, and forceful plugging of ribbon cables is strictly prohibited to prevent damage to the digital pins of the onboard microprocessor. The operating loop must be strictly limited to three-phase 380–500V AC power networks and motor systems within 75kW/105A, ensuring that input parameters stay within the rated monitoring limits of the hardwired logic circuits.

Furthermore, a proper controlled voltage ramp-up time (starting slope) must be preconfigured based on the load characteristics; once the internal measurement circuitry triggers a microsecond-level trip and registers it in the status log due to an out-of-tolerance event, a comprehensive inspection of the physical components for overload, short-circuit, or over-temperature conditions must be performed, and forced reset restarts without resolving the anomaly are strictly forbidden.

Alternative Names

ISFB536068D1011 1SFB536O68D1O11 1SFB536068D10II 1SFB536068DI011 ISFB536068DI0II 1SFB536068-D1011 1SFB 536068 D1011 1SFB-536068-D1011

Technical notes

1SFB536068D1011 is the core control board (designated as PSPCB-LV/T) for ABB's 105A soft starters, including PST105-600-70 and PSTB105, supporting three-phase 380-500V AC asynchronous motor systems up to 75kW. Utilizing an onboard microprocessor for real-time acquisition of voltage, current, and frequency, the hardware executes a controlled voltage ramp-up algorithm to substitute direct-on-line starting, thereby counteracting high-current surges, network voltage dips, and mechanical wear; meanwhile, it integrates automatic fault detection circuitry for overload, short-circuit, over-temperature, and over/under-voltage conditions, automatically triggering protective responses and registering abnormal events into the system status log when parameters exceed tolerances.

FAQ View All FAQ

  • What is 1SFB536068D1011?
    It is the core control motherboard within ABB's PST/PSTB series low-voltage soft starter systems, carrying the specific hardware designation of the PSPCB-LV/T terminal control board.
  • How to use 1SFB536068D1011 in industrial systems?
    Mounted as the central control unit inside an ABB soft starter enclosure, this board connects to main circuit thyristors (SCRs), current transformers, and PLC control signals via wiring terminals.
  • Which specific soft starter models is 1SFB536068D1011 compatible with?
    It directly fits soft starter models with a rated current up to 105A, with specific compatible model numbers including PST105-600-70 and PSTB105.
  • Which PLC systems are compatible with 1SFB536068D1011?
    It seamlessly integrates with mainstream industrial PLCs, such as ABB's own AC500 series PLCs, to achieve automated logic control.
  • What electrical protection features does 1SFB536068D1011 provide?
    The board integrates overload, undervoltage, overvoltage, and phase-loss protections to effectively prevent motor burnout under abnormal operating conditions.
Manufacturers

Product Browsing History

Revisit the products you recently viewed on Apter Power.
SPEAK TO OUR TEAM
Let’s find the right solution for you.
Send us the part number, quantity and delivery destination. Our team will help confirm availability and lead time.
  • Whatsapp: +86 18030235313

    Send us a message.