Get Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel

505-4632

32-Point AC Output Module
In Stock
Ships by Monday, October 26
Fast Shipping Available

Product Describe:

Siemens 505-4632 is a single-wide SIMATIC 505 module with 32 non-latching AC outputs for 24 to 115 V AC field loads.

Ask our team:

Get a quick price for: 505-4632
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for 505-4632

Technical specifications for 505-4632

  • Manufacturer:
    Siemens
  • Product Category:
    PLC Systems
  • Spare Part Number:
    505-4632
  • Estimated shipping dimensions:
    4x18.6x26.5cm
  • Weight:
    0.66 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Germany
  • Output channels:
    32
  • Rated load supply:
    24 to 115 V AC
  • Operating range:
    20 to 132 V AC
  • Frequency:
    47 to 63 Hz
  • Minimum load:
    5 mA
  • Overload:
    5 A RMS for two cycles
  • ON-state drop:
    1.8 V at 0.5 A
  • Surge protection:
    R-C suppressor
  • Output behavior:
    Non-latching, unprotected
  • Module format:
    Single-wide

Information

Information

Overview Manuals Common Applications Product Precautions
Siemens 505-4632 supplies thirty-two triac-switched AC output points from one SIMATIC 505 rack position.
  • Provides 32 AC output channels.
  • Operates across 20 to 132 V AC at 47 to 63 Hz.
  • Uses an R-C surge suppressor on the output circuits.
  • Uses a single-wide module format.

The 32-point ac output module belongs to the SIMATIC 505 modular control platform. Selection must preserve the documented signal role, terminal arrangement and rack interface.

Important Notice: Verify the complete Siemens 505-4632 marking, terminal assignment, rack position and configured signal behavior before replacement.

Siemens 505-4632 Manuals & Downloads
Siemens 505-4632 Technical Reference (PDF)Siemens 505-4632 Installation & Commissioning Guide (PDF)

The Technical Reference covers the product function, system role and technical selection. The installation guide covers identification, connection checks, commissioning and the acceptance record.

AC contactor control
Switch approved AC relay or contactor coils under PLC logic.
Machine auxiliaries
Operate lamps, small valves and other compatible AC loads.
Process sequencing
Distribute mains-level output commands through the existing point map.
Rack maintenance
Retain a 32-channel AC output function in a SIMATIC 505 installation.
Before installing Siemens 505-4632, confirm the documented system, interfaces and controlled configuration.
1
Verify every connected load is compatible with the documented AC range.
2
Isolate rack and external load power before handling conductors.
3
Record channel, common and branch-protection assignments before removal.
4
Review steady-state and inrush current for each controlled load.
5
Retain the approved fuse and upstream protective-device coordination.
6
Separate AC output wiring from low-level signal wiring.
7
Check for unintended leakage-driven operation before enabling the process.
8
Command each point and verify the field load and PLC indication agree.

Technical notes

Technical notes

Verify the complete Siemens 505-4632 marking, terminal assignment, rack position and configured signal behavior before replacement.

FAQS

  • How many AC outputs are available on Siemens 505-4632?
    It provides 32 AC output channels.
  • Which voltage range can Siemens 505-4632 switch?
    The operating range is 20 to 132 V AC, with a rated range of 24 to 115 V AC.
  • Which frequency range applies to Siemens 505-4632?
    The outputs are specified for 47 to 63 Hz.
  • What minimum load is specified for Siemens 505-4632?
    The minimum load is 5 mA.
  • Which surge network is used by Siemens 505-4632?
    The output circuits use an R-C surge suppressor.
  • Are Siemens 505-4632 outputs protected against every field fault?
    No. The outputs are documented as unprotected, so branch protection and load checks remain necessary.
  • What should be checked for AC coil loads on Siemens 505-4632?
    Confirm steady-state current, inrush current, suppression and the required protective-device coordination.
  • How is Siemens 505-4632 accepted after installation?
    Command every channel and verify the correct field load, indication and interlock behavior.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.