T8842

Trusted 40 Channel Versatile FTA

Product Describe:

Trusted 40 Channel Versatile FTA
I/O Configuration: Individually 
configurable as AI, DI, or DO
Mounting: Standard DIN Rail (TS32/TS35)
SIL 3 

Ask our team:

Get a quick price for: T8842
Quantity*
Upload (gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Apterpower please read our privacy policy.

Technical specifications for T8842

Technical specifications for T8842

  • Manufacturer:
    ICS Triplex
  • Product Category:
    PLC Systems
  • Spare Part Number:
    T8842
  • Estimated shipping dimensions:
    23.5x12.5x6cm
  • Weight:
    0.85 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    USA
  • Operating Voltage Range:
    18 Vdc to 28 Vdc
  • Field Power Distribution:
    5 groups of 8 channels each
  • Input Signal Types:
    2-wire or 3-wire field devices
  • Output Signal Types:
    Digital signals for solenoid valves
  • Operating Temperature:
    -5 °C to +60 °C (+23 °F to +140 °F)
  • Storage Temperature:
    -25 °C to +70 °C (-13 °F to +158 °F)
  • Compatible Controllers:
    Trusted TMR T8448 / T8449 Modules

Information

Information

Overview Manuals Common Applications Product Precautions
The T8842 typically refers to the Trusted series multi-function field terminal block assembly manufactured by ICS Triplex. It is an interface component for mission-critical safety systems, primarily used in Rockwell ICS Triplex Trusted redundant systems.
    • Standard DIN rail compatibility
    • Simple installation and connection
    • Field power supply arranged in five groups of eight channels
The Trusted Versatile Field Termination Assembly (VFTA) T8842 is primarily designed to act as the main interface between field devices associated with the detection and suppression of fire and gas hazards, and the Trusted Triple Modular Redundant (TMR) Zone Interface Module T8448. It is also used as the interface for the Trusted TMR Valve Monitor Module T8449, for which digital outputs to solenoid valves alternate with valve position analogue inputs. Each channel of the VFTA is configurable to enable a variety of field devices to be connected. These include devices generating both analogue and digital input signals, and output devices requiring a digital signal at up to 28 Vdc.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. 
 ICS Triplex T8842 Trusted 40 Channel Versatile FTA Manuals, Datasheets, Drivers, Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description.
Liquefied Natural Gas
Monitoring cryogenic valve status to prevent pressure loss during the liquefied gas vaporization process.

Oil Pipelines
Acquiring leak detection signals and valve control at intermediate pumping stations.

Steel & Metallurgy
Monitoring toxic gas concentrations in Blast Furnace Gas (BFG) recovery systems.

Chemical Processing Plants
Monitoring temperature and pressure interlocks in highly exothermic reaction processes.

Pulp & Paper Industry
Acting as an interface for Burner Management Systems (BMS) in chemical recovery boilers.

Semiconductor
Monitoring and automatically shutting down ultra-low concentration leaks in highly toxic/flammable gas lines like Silane.

 It is critical to accurately configure the corresponding plug-in resistor kits and fuses based on the field signal type (AI, DI, or DO) and ensure all terminal connections are secure to maintain SIL 3 system reliability. During operation, strictly adhere to the 18-28 Vdc power range and regularly inspect the channel fuse status indicators to prevent a single-point failure from affecting the stability of the grouped power supply (5 groups of 8 channels).

FAQS

  • What is the ICS T8842?
    It is a Trusted Versatile Field Termination Assembly (VFTA), acting as the main interface between field devices and the safety control system.
  • How do I install the ICS T8842?
    It is designed for easy installation on a standard 35mm DIN rail, typically within a control cabinet.
  • How many physical channels does the ICS T8842 have?
    It has 40 high-density channels, supporting the connection of a large number of field devices on a single component.
  • What is the purpose of the hot-swappable nature of ICS T8842 accessories?
    Although the board itself is not frequently moved, its components (such as fuses) can be replaced while the circuit is powered on, allowing for single-channel maintenance without affecting the overall operation of the machine.
  • How does the ICS T8842 manage field power?
    It divides the 40 channels into 5 independent groups (8 channels per group), allowing users to control power supply based on logical grouping.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Product Browsing History

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.