X67SM2436 operates with X67 bus connection, two compatible stepper motors, 24-to-38.5 V DC power supply, motor cables and encoder wiring.
Engineered applications include Indexing conveyor axes, Dual stepper positioning, Distributed actuator station, Stepper-module replacement.
Important Notice: Record motor phase order, current limits, encoder assignment and axis parameters; isolate motor energy before disconnecting either axis.
The first document presents model-specific engineering data. The second provides a separate installation, connection, commissioning and acceptance workflow.
Positions two conveyor or feeder axes.
Coordinates paired stepper mechanisms.
Places motion electronics near the machine.
Restores motor current and encoder configuration.
Verify the full X67SM2436 marking and its assigned B&R X67 distributed motion I/O position before work.
Place the connected machine or process in the approved maintenance state.
Isolate the applicable supply and two stepper-motor phase outputs plus digital/encoder feedback field energy before disconnecting conductors.
Record connector, conductor, address and software identities before removal.
Use ESD controls and protect keyed interfaces, exposed contacts and electronic assemblies.
Confirm the installed X67 bus connection and two compatible stepper motors against the approved project.
Restore power in a controlled sequence and review device, network and host diagnostics.
Prove the intended indexing conveyor axes function and retain the final test result.