Technical specifications for X20SL8010

Technical specifications for X20SL8010

  • Manufacturer:
    B&R
  • Product Category:
    PLC Systems
  • Spare Part Number:
    X20SL8010
  • Estimated shipping dimensions:
    9.8x2.5x5.5cm
  • Weight:
    0.06 kg
  • Tariff Code:
    8537101190
  • Counliy of origin:
    Austria
  • System module:
    SafeLOGIC CPU
  • Safety level:
    SIL 3 / Cat. 4 / PL e
  • Supported safety nodes:
    Maximum 20
  • POWERLINK ports:
    2 shielded RJ45
  • Transfer rate:
    100 Mbit/s
  • Shortest task cycle:
    1 ms
  • Power supply:
    24 VDC -15%/+20%
  • Power consumption:
    5.1 W
  • SafeKEY:
    Ordered separately
  • Supply:
    24 VDC -15/+20%

Information

Information

Overview Manuals Common Applications Product Precautions
B&R X20SL8010 is a safelogic controller for the documented X20 System installation.
  • Provides central safety application execution
  • Uses exact B&R article identity X20SL8010
  • Matches system module: SafeLOGIC CPU
  • Matches safety level: SIL 3 / Cat. 4 / PL e

The product performs central safety application execution in the documented X20 openSAFETY system. Installation and commissioning must preserve the exact identity, interfaces and approved configuration.

Important Notice: Confirm B&R X20SL8010, X20 openSAFETY system, POWERLINK, SafeKEY and safety application, wiring, grounding, configuration, companion accessories and controlled commissioning results before service release.

Apter Power X20SL8010 Manuals and Guides

The first document is the model-specific technical and system reference. The second is a distinct field workbook for installation, wiring, commissioning and acceptance records.

X20 System system maintenance
Restores central safety application execution in the documented installation.
Controlled hardware replacement
Preserves the exact X20SL8010 identity and approved configuration.
Interface verification
Confirms POWERLINK, SafeKEY and safety application before energization.
Functional recommissioning
Reviews diagnostics and records the controlled system response.
Read the applicable B&R installation instructions before work. Verify X20SL8010, the installed host system and all configured field interfaces before isolation, wiring or commissioning.
1
Confirm the complete B&R X20SL8010 marking and installed X20 System position before work.
2
Place the machine or process in the approved maintenance state and isolate every applicable energy source.
3
Record POWERLINK, SafeKEY and safety application, terminal assignments, shielding and protective-ground connections before removal.
4
Use ESD controls and protect keyed connectors, terminals and exposed electronics from contamination.
5
Verify system module (SafeLOGIC CPU) against the installed project and connected hardware.
6
Verify safety level (SIL 3 / Cat. 4 / PL e) and restore only the approved configuration.
7
Energize in the prescribed sequence and review module, host and network diagnostics.
8
Complete a controlled central safety application execution test and retain the acceptance result before production release.

Technical notes

Technical notes

Confirm B&R X20SL8010, X20 openSAFETY system, POWERLINK, SafeKEY and safety application, wiring, grounding, configuration, companion accessories and controlled commissioning results before service release.

FAQS

  • How is the exact X20SL8010 execution identified?
    Match the complete B&R X20SL8010 marking and the controlled installed-position record.
  • What documented role does X20SL8010 perform?
    It performs central safety application execution in the documented X20 openSAFETY system.
  • Which host must be matched before fitting X20SL8010?
    Match the exact X20 openSAFETY system and approved system position.
  • Which interfaces must be recorded for X20SL8010?
    Record POWERLINK, SafeKEY and safety application, mounting, shielding, grounding and cable routing.
  • What isolation controls apply to X20SL8010?
    Place the machine or process in the approved maintenance state and isolate every applicable energy source.
  • What must be restored after installing X20SL8010?
    Verify safety level (SIL 3 / Cat. 4 / PL e) and restore only the approved configuration.
  • What proves X20SL8010 is ready for service?
    Retain diagnostics and a controlled central safety application execution response test.
  • Which manufacturer record supports the X20SL8010 page?
    Data sheet X20SL8010 and the official B&R product record for X20SL8010.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, modules and cards, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer`s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

We’re Here When You Need Us

From product insights to customer service needs, our experienced service team will focus on getting you what you need quickly

Enquire

Complete our online form.

Call Us

Speak to one of our team.

Live Chat

Send us a message.